Abstract
A significant portion of pharmaceuticals and other organic chemicals consumed by people and animals are released into municipal wastewater treatment plants. Most of them are degraded during the wastewater treatment processes, but some of them degrade only partially and may be widely transported and dispersed into the aquatic environment. This is why efficient and fast analytical methods are needed for detection of organic compounds in wastewaters at trace levels. Because wastewaters often consist of complex matrices and high-molecular mass materials, e.g., lignocellulosic biomass, which may bring challenges to the sample preparation procedures, efficient pre-concentration methods such as solid phase extraction (SPE) solid phase microextraction (SPME), or single‑drop microextraction (SDME) are needed. The most common analysis methods are gas chromatography (GC) and liquid chromatography (LC) coupled with tandem mass spectrometry (MS/MS). The aim of this review is to give an overview of chromatographic and spectroscopic methods when characterizing low- and medium-molecular weight organic pollutants, mainly focusing on pharmaceuticals, biocides, and personal care products in environmental matrices.
Download PDF
Full Article
Analysis of Trace Pharmaceuticals and Related Compounds in Municipal Wastewaters by Preconcentration, Chromatography, Derivatization, and Separation Methods
Petra C. Lindholm,a,* Juha S. Knuutinen,a Heidi S. J. Ahkola,b and Sirpa H. Herve b
A significant portion of pharmaceuticals and other organic chemicals consumed by people and animals are released into municipal wastewater treatment plants. Most of them are degraded during the wastewater treatment processes, but some of them degrade only partially and may be widely transported and dispersed into the aquatic environment. This is why efficient and fast analytical methods are needed for detection of organic compounds in wastewaters at trace levels. Because wastewaters often consist of complex matrices and high-molecular mass materials, e.g., lignocellulosic biomass, which may bring challenges to the sample preparation procedures, efficient pre-concentration methods such as solid phase extraction (SPE) solid phase microextraction (SPME), or single‑drop microextraction (SDME) are needed. The most common analysis methods are gas chromatography (GC) and liquid chromatography (LC) coupled with tandem mass spectrometry (MS/MS). The aim of this review is to give an overview of chromatographic and spectroscopic methods when characterizing low- and medium-molecular weight organic pollutants, mainly focusing on pharmaceuticals, biocides, and personal care products in environmental matrices.
Keywords: Extraction techniques; Gas Chromatography; Derivatization; Liquid Chromatography; Mass Spectrometry; Municipal wastewater; Pharmaceuticals; Personal care products; Separation methods; Single‑drop microextraction; Solid phase extraction; Solid phase microextraction
Contact information: a: Department of Chemistry, University of Jyväskylä, P.O. Box 35, FI-40014 University of Jyväskylä, Finland; b: Finnish Environment Institute, Laboratory Center, Research and Innovations, P.O. Box 35 FI-40014 University of Jyväskylä, Finland;
*Corresponding author: petra.lindholm@jyu.fi
INTRODUCTION
Organic compounds can be divided according to their molecular weight. Low molecular weight (LMW) usually refers to compounds with a molecular weight lower than 350 Da (Fiorentino et al. 2003), including monomeric and often volatile compounds. Compounds with a molecular weight of more than 1000 Da are considered to be of high molecular weight (HMW), while medium molecular weight (MMW) represents compounds with a molecular weight between 350 and 1000 Da. Organic compounds with a high molecular weight include polymers, lignocelluloses, and humic substances, but compounds with toxic properties found in environmental matrices often belong to the MMW class, together with pharmaceuticals, personal care products, and biocides.
Typically, effluent from a municipal wastewater treatment plant contains on the average 200 mg/L COD, 110 mg/L BOD5, and 150 mg/L suspended solids (SS), while the amount of total nitrogen and phosphorous are 20 and 2 mg/L, respectively (Champagne and Li 2009). The primary sludge typically has a pH of about 6.9 and contains 4% SSs of which 29% is cellulosic material. Municipal wastewaters, sludges, and biosolids include fecal materials, scraps of toilet paper, food residues, humic substances, and other organic materials that contain large quantities of cellulosic and lignocellulosic substances.
Municipal wastewaters contain a wide variety of organic compounds in trace amounts, including pharmaceuticals and personal care products (PPCPs). For example, medications, nutraceuticals, detergents, perfumes, and cosmetics have been widely detected in surface and wastewaters (Metcalfe et al. 2003a,b). Studies have shown that PPCPs may cause behavioral changes in aquatic organisms, even at low concentrations (Kümmerer 2004; Fent et al. 2006). Concentrations of pharmaceuticals found in the receiving water reflect the concentrations in wastewaters and the persistence of the compounds. It has been found that pharmaceuticals occur more widely in surface water than groundwater because the surface waters are more often affected by wastewater effluents (Rohweder 2003). However, increasing the water flow in wastewater treatment plants or in rivers does not lead to a proportional dilution of the pollutants (Giger 2009).
Most pharmaceuticals are found in low concentrations, and some of them are polar and not easily degradable. Antibiotics are used in human and veterinary medicine worldwide. They are an interesting subject because their effect on the natural environment is insufficiently known (Giger 2009). As reported by Göbel et al. (2007), significant elimination of antibiotics does not occur during primary wastewater treatment. On the other hand, some antibiotics are partially removed in activated sludge systems, fixed-bed reactors, and membrane bioreactors. However, chemicals such as most fluorochemicals are not removed by wastewater treatment plants and can be distributed and conserved within tens of kilometers from the source (Huset et al. 2008).
There is a wide range of compounds used as biocides, such as oxidizing compounds (e.g., chlorine and chlorine dioxide), halogenated compounds (e.g., bronopol), and sulfur compounds, including isothiazolone and carbamates. The biological degradation and removal of biocides in wastewater treatment plants have been widely studied (e.g., Okuda et al. 2008; Zorita et al. 2009), but the process of removal does not always result in a complete mineralization of compounds. The metabolites of pharmaceuticals pass through wastewater treatment plants and end up in rivers and other environmental systems (Wise 2002; Gros et al. 2007). It has been shown (Sinclair and Boxall 2003; Juraske et al. 2007; Escher et al. 2009) that some transformation products of pesticides exhibit a similar or even more toxic effect than their parent compounds.
Transformation products are formed in raw water during processes such as biodegradation, photolysis, hydrolysis, flocculation, oxidation, and disinfection. However, more data about the occurrence and effects of transformation products in the environment and during water treatment are needed (Zwiener 2007). There are various challenges in modern aquatic environmental analysis. Even though most of the pharmaceuticals are designed to be water-soluble and biodegradable, they often have high tendency of bioaccumulation and high affinity to sludge and soil (Aznar et al. 2014). Pharmaceuticals in soil have the ability to be taken up by edible plants and enter the food chain (Shenker et al. 2011). Because most of the analysis methods are focused on the aquatic samples and polar compounds contained in them, this may lead to incorrect results of concentrations and problems related to sample preparation methods. Therefore, the development of suitable sample preparation and analysis methods plays an important role in the study of the behavior and transportation of chemicals in the aquatic environment.
The aim of this review is to focus on the analysis methods of LMW and MMW organic compounds detected in trace amounts in waste and natural waters. The focus is on detecting and quantifying target compounds in complex environmental matrices. In addition, current alternatives of analysis methods are discussed, including new applications. However, HMW organic compounds and pollutants from industrial wastewaters are excluded. Considering the wide variety of compounds and the importance of their analysis, a review focused on HMW compounds, including lignocelluloses, is recommended for further research.
Sampling and Sample Preparation
Passive sampling
Pollutants are often found in natural waters at low ng/L levels, but the results may vary depending on sampling conditions such as rainfall, overload at a wastewater treatment plant, or a recent field spreading of manure. Therefore, samples should be collected frequently, but time, costs, and available resources may restrict such sampling (Camilleri et al. 2012). Traditionally, water samples have been collected as grab samples, but in that case, information only reflects the sampling moment, and relevant events such as high or low flow can be missed. Continuous on-line sampling can provide information over extended periods of time but is expensive and needs maintenance, which may prohibit its use, especially during the colder months (Vrana et al. 2005).
Fortunately, passive samplers have been developed to optimize water sampling by mimicking the accumulation of hydrophobic substances (Kingston et al. 2000; Camilleri et al. 2012). Passive sampling is usually based on diffusion through a barrier or permeation through a membrane, but living organisms can also be used as samplers. Generally, passive sampling combines sampling and sample preconcentration into a single step. It often simplifies sampling, sample preparation, and any following steps in the analytical procedure. Power requirements are eliminated, and the costs of analyses are significantly reduced. Furthermore, it is possible to combine passive techniques with grab sampling, which reduces the time required for the analytical sequence (Górecki and Namieśnik 2002).
Contaminant concentrations over longer time periods can be sampled with passive samplers such as semipermeable membrane devices (SPMDs) and polar organic chemical integrative samplers (POCISs). They are designed for the accumulation of hydrophilic or lipophilic substances (Södergren 1987; Huckins et al. 1990; Vrana et al. 2005). The receiving phase of SPMD is made of polyethylene tubing or other polymer-containing hydrophilic or lipophilic thin films, made of, e.g., triolein or hexane. This method is based on an equilibrium state between the phase and the environment, e.g., air or water.
POCISs are based on the adsorption of pollutants with phases made of polymer and used for the sampling of polar and hydrophilic compounds in water (Alvarez et al. 2005; MacLeod et al. 2007; Söderström et al. 2009). POCISs are easy to use and resistant to biofouling (Alvarez et al. 2004). In addition, Alvarez et al. (2005) reported that, compared to grab water samples, POCIS can improve detection limits, enabling the detection of compounds with low concentrations. POCIS sampling has been employed, for example, for pesticides (diuron and isoproturon), PPCPs (axithromycin, fluoxetine, levothyroxine, and omepratzole), and illicit drugs such as methylenedioxy methamphetamine, and methamphetamine, but the analyses have mostly been qualitative (Jones-Lepp et al. 2004). Quantitative analysis of polar compounds in water is limited because a targeted calibration study is needed for most PPCPs. However, a qualitative and semiquantitative technique has been reported for analyzing common PPCPs in flowing water (MacLeod et al. 2007). The time-weighted average concentrations calculated using sampling rates obtained from laboratory calibrations were consistent with those from regular grab sampling.
The Chemcatcher was developed to monitor polar and hydrophobic compounds in water matrices (Kingston et al. 2000). The Empore disk receiving phase is covered with a polyethersulfone (PES) diffusion membrane and placed in a sampler housing made of polycarbonate or polytetrafluoroethylene (PTFE). A variety of adsorption phases are available for the polar configuration, such as octadecyl (C18), poly(styrenedivinyl-benzene) (SDB-XC), and sulfonated poly(styrenedivinyl-benzene) copolymer (SDB-RPS) (Ahkola et al. 2013). For example, the C18 Empore disk receiving phase provides mainly non-polar interactions with hydrophobic molecules via octadecyl functional groups bonded to silica surface (Greenwood et al. 2007). However, the silica material has also non-substituted silanol groups and molecules with polar functional groups have a high affinity towards them. Thus the sorbent is suitable for collecting compounds with different properties. Passive samplers need to be calibrated under specific conditions of pH, temperature, conductivity, and salinity before use (Zhang et al. 2008). Even though the exposure conditions cannot be reproduced in real life and variations between laboratory and in situ calibrations occur, analyte concentrations obtained by passive sampling generally are in good agreement with those from grab sampling.
Solid phase extraction
Sample preparation is one of the most important steps of the analysis procedure. Previously, sample preparation of a variety of environmental samples most commonly was performed by liquid-solid (LSE) or liquid-liquid extraction (LLE) with organic solvent, followed by clean-up and preconcentration steps. Because these methods are labor- and time-consuming, costly, and require discarding toxic solvents, there has been a need to develop faster and more environmentally friendly extraction methods (Jiang et al. 2006). Currently, the most widely used preconcentration method for analytes in aqueous matrices is solid phase extraction (SPE) (e.g., Jiang et al. 2006; Garcia-Ac et al. 2009; Kim et al. 2013). Other preconcentration methods include solid phase microextraction (SPME), single-drop microextraction (SDME), dispersive liquid-liquid microextraction (DLLME), and vortex-assisted liquid-liquid microextraction (VALLME). The advantage of these techniques is that they require only small volumes of potentially harmful organic solvents.
To reach low enough detection limits (ng/L) for analytes in environmental samples, a preconcentration step is almost always needed. For the preconcentration, SPE is the most widely used method because, in addition to the extraction of organic compounds, it also removes interfering components from the matrix (Rodriguez-Mozaz et al. 2007). However, in order to achieve a detection limit below 10 ng/L, high enough extraction volumes are required. For example, for the extraction of water samples with C18 SPE cartridges a volume of 250 mL is needed (Cherta et al. 2012).
The SPE method is based on physical adsorption of organic compounds on the surface of solid supports. Only a small volume of solvent compared to traditional LLE is required because the analyte is directly extracted from the liquid sample onto the sorbent material. SPE combines the enrichment and extraction steps and provides high sensitivity. In addition, it is clean, selective, rapid, and efficient. SPE can be used with different detection techniques on-line as well as off-line. In on-line applications, no sample manipulation is required between preconcentration and analysis, which reduces the risk of loss and contamination (Das et al. 2012). It also improves the precision and accuracy of the analysis and increases the sample throughput (Rodriguez-Mozaz et al. 2007).
A wide range of SPE materials is available. The trapping mechanism of SPE is often based on hydrophobic interactions, and the most common SPE sorbent materials for the enrichment of contaminants are alkyl-bonded silicas (e.g., C2 or C18 silicas) and copolymer sorbents. Because the more selective SPE step provides better sensitivity, tailor-made sorbent materials have been developed for the extraction of target materials (Rodriguez-Mozaz et al. 2007).
Solid phase microextraction
Solid-phase microextraction (SPME), originally developed by Arthur and Pawliszyn (1990), has become popular in the analysis of organic compounds because it combines sampling and pre-concentration in one step (López-Blanco et al. 2003). SPME is a simple and solventless method based on extraction with a thin polymeric-coated fused-silica fiber, fitted in a syringe-type holder for sampling. When the fiber is exposed to an aqueous solution, organic compounds are extracted. After sampling, the fiber is transferred to the heated injection port of a GC system, where the analytes are thermally desorbed. This procedure takes only minutes and can be easily automated (Psillakis and Kalogerakis 2001b).
Compared to SPE, SPME requires smaller sample volumes and gives higher limits of detection (Hernández et al. 2001). In the SPME, the analytes are extracted from various gas or water media by fused-silica fibers coated with a stationary phase. The technique integrates sampling, extraction, concentration, and sample introduction into one step (Wu and Huang 1999). SPME fibers can be divided into adsorbent- and absorbent-type fibers. Adsorbent-type fibers extract the analytes by physical interaction, while absorbent-type fibers extract by partitioning the analytes into a liquid-like phase (Luks-Betlej et al. 2001).
SPME sampling can be divided into two categories: immersion sampling, where the fiber is immersed in the aqueous sample, and headspace sampling, where the fiber is exposed to the headspace above the liquid or solid sample (Lord and Pawliszyn 2000). Immersion sampling enhances extraction, while headspace sampling works well for analytes of low molecular mass. In addition, an increase in the sample temperature enhances headspace extraction (Kirkbride et al. 1998), but it is not recommended for non-volatile or thermally unstable compounds such as octogen (HMX).
SPME is suitable for the extraction of non-polar organics such as fuel components, polycyclic aromatic hydrocarbons (PAHs), and polychlorinated biphenyls (PCBs) in water samples. In addition, many pesticides, phenols, organic acids, and aliphatic amines can be extracted because more polar solvents and in situ derivatization techniques for SPME have been developed. Ideally, SPME of organic acids and bases can be performed without a derivatization step, especially if no derivatization is needed for the following analysis (van Doorn et al. 1998). SPME fibers can be used for up to 100 extractions, but they are fragile and expensive. In addition, a thermal conditioning step is required before using a fiber for the first time, and a partial loss of coating may still occur, resulting in extra peaks during chromatographic analysis (Psillakis and Kalogerakis 2001b).
Van Doorn et al. (1998) reported that organic acids and bases can be selectively extracted by SPME by adjusting the pH of water samples before the extraction. The sorption behavior of organics can be predicted on the basis of the acid dissociation constant in water. Many organic acids and bases have dissociation constants in the same range as water samples (e.g., surface water from 5 to 8), but relatively small changes in pH have a dramatic effect on their SPME/water distribution behavior. In addition, quantitative errors can occur when the pH of the sample and that of the calibration water vary significantly. The selectivity of SPME can be increased by buffering the water samples. On the other hand, a pH of the sample solution in the range of 3 to 9 does not have a significant effect on the extraction efficiency when using Carbowax templated resin (CW–TPR) or polydimethylsiloxane-divinylbenzene (PDMS–DVB) fiber, but the absorption decreases if the pH is adjusted to 11 due to the ionization of the weak acids. The temperature, 20 °C has been shown to be optimum for the absorption, while at 10 °C, the absorption and the rate of diffusion decrease. Additionally, the amount of analytes absorbed decreases with increasing temperature due to a decrease of the distribution constant (Wu and Huang 1999).
There are several types of commercially available SPME fibers. A fiber coating should be selected with a polarity close to the polarity of the target analytes (Namieśnik et al. 2000). For polar analytes, polar CW-TPR provides the highest extraction yields, while moderately polar PDMS-DVB fiber is more suitable for less polar analytes (Wu and Huang 1999). Generally, polyacrylate (PA) and carbowax-divinylbenzene (CW-DVB) show higher fiber/water sorption coefficients than polydimethylsiloxane (PDMS)-coated fiber. Depending on the water pH, PA fiber is more selective for acid or basic components than CW–DVB fiber (van Doorn et al. 1998).
Single-drop microextraction
To reduce solvent consumption and the time required for extraction, an alteration of the traditional liquid-liquid extraction method called single-drop microextraction (SDME) has been introduced (Liu and Dasgupta 1996). In SDME, a microdrop of a water‑immiscible solvent is suspended on the tip of a microsyringe and immersed in the sample solution. Organic contaminants are transferred to the organic phase, and the microdrop is retracted into the syringe after the sampling and used for further analysis. SDME has been successfully used for analyses of, e.g., alcohols (Tankeviciute et al. 2001), nitroaromatic explosives (Psillakis and Kalogerakis 2001a), chlorobenzenes (Wang et al. 1998), and volatile organic compounds in water (Buszewski and Ligor 2002).
SDME extraction involves only a few microliters (0.5 to 2.5 µL) of organic solvent and can be viewed as a virtually solvent-free sample preparation technique. Only a small amount of sample is needed, and sample concentrations of a few mg/L are sufficient. SDME eliminates the problems of peak tailing and sample carry-over often encountered in LLE and SPE and also the fiber degradation of SPME (López-Blanco et al. 2003). In addition, only inexpensive equipment commonly found in laboratories are needed, thus minimizing the costs of analysis per sample (Psillakis and Kalogerakis 2001b).
SDME and SPME are equilibrium techniques, and the determination is possible in 15 to 20 min, much quicker than SPE, which is an exhaustive technique. It is possible to achieve 100% recovery of the analyte in SPE, but it requires a longer analysis time and larger volumes of organic solvent. Because SDME is dependent on the solubility of target compounds, the choice of the water-immiscible solvent is essential (López-Blanco et al. 2003). For example, for α- and β-endosulfan, de Jager and Andrews (2000) recommended hexane, but López-Blanco et al. (2003) suggested isooctane because of its higher extraction capacity.
In general, the choice of the organic solvent for SDME should be based on a comparison of selectivity, extraction efficiency, incidence of drop loss, rate of drop dissolution, and the level of toxicity. For example, toluene can be used because it has good selectivity and almost no solvent is lost. The main drawbacks of SDME compared to SPME are the prolonged extraction times and the fact that faster stirring rates are not recommended because they usually result in drop dissolution and/or dislodgment. In addition, the microdrop-based method requires careful manual operation (Psillakis and Kalogerakis 2001b).
Dispersive liquid-liquid microextraction
Rezaee et al. (2006) introduced dispersive liquid-liquid microextraction (DLLME) based on a ternary component‑solvent system. A water-immiscible extractant solvent dissolved in a water-miscible dispersive solvent is injected into an aqueous donor solution, leading to a cloudy solution consisting of fine droplets of extractant. Target analytes are extracted into these droplets and subsequently separated by centrifugation. However, the method is difficult to automate, and the use of a disperser solvent often decreases the partition coefficient.
A dispersion of extractant into the sample solution can also be achieved using temperature-controlled DLLME, which is based on the ability of an ionic drop to disperse at higher temperature and separate when cooling, followed by centrifugation (Zhou et al. 2008). Even though high enrichment factors are gained, analyte losses due to volatilization at high temperatures are possible. Finally, Regueiro et al. (2009) explored the possibility of using ultrasound for dispersing the extractant, such as an organic solvent or an organic solvent/ionic liquid mixture, into an aqueous donor phase. The process is also called homogenization and is a known alternative to LLE. Ultrasound speeds up the homogenization step and increases the formation of submicron size droplets and thus the contact surface between the two liquids. However, ultrasound has been found to produce stable emulsions that result in long separation times (Luque de Castro and Priego-Capote 2007).
Vortex-assisted liquid-liquid microextraction
Vortex-assisted liquid-liquid microextraction (VALLME) is a fast equilibrium-based solvent microextraction technique used for the trace analysis of pollutants in water samples (Yiantzi et al. 2010). A mild emulsification is achieved by the dispersion of a low‑density organic solvent into an aqueous phase using vortex mixing (Zacharis et al. 2012). The fine droplets formed can extract target analytes faster because of a shorter diffusion distance and larger specific surface area. After the extraction, centrifugation is performed to achieve phase separation. The advantage of VALLME is that equilibrium conditions can be achieved within minutes. Only mild conditions are required for emulsification, and problems associated with ultrasound can be avoided. In the case of more complex matrices, analytes can be determined using the addition of a standard. Recently, the method has been extended using a surfactant as a disperser in the emulsification to improve the mass transfer of analytes from the aqueous to the organic phase (Yang et al. 2011). However, surfactants often have a low volatility, which may cause them to contaminate the inlet or the stationary phase of the GC system (Zacharis et al. 2012).
Immunosorbent extraction
Depending on the composition of the sample, sample pretreatment may involve numerous steps. Immunosorbents have been used in the analysis of environmental water samples because they enable extraction, trace enrichment, and clean-up in one step. Immunosorbents have been found to be highly selective (> 90%) and to give nearly quantitative (> 90%) yields (Ferrer and Barcelò 1999; Ferguson et al. 2001).
The antibody of the immunosorbent is immobilized onto a silica support and used as an affinity ligand in the extraction of target analytes and similar species from the sample (Ferrer and Barcelò 1999). Even though the stability of the immunosorbent has not yet been established, the sorbent can be used for six times without any noticeable decrease in recoveries (Ferguson et al. 2001). In addition, immunosorbents prepared with solid silica supports have a lifetime of more than 100 extraction cycles when used in the isolation of PAHs from sediment and sewage sludge samples (Peréz et al. 1998).
Immunosorbent extraction has been used as a selective technique, for example, in the preconcentration of pesticides and polycyclic aromatic hydrocarbons prior to analysis with high performance liquid chromatography (HPLC) or gas chromatography (GC) (Ferrer and Barcelò 1999). In addition, immunosorbent extraction coupled with LC and electrospray ionization mass spectrometry detection (ESI-MS) is also suitable for the determination of other environmentally relevant compound classes, such as pharmaceuticals (Ferguson et al. 2001). Currently, pharmaceuticals are often analyzed by LC-MS/MS, and the analyses may be simplified using commercial antibodies (Ternes et al. 1998b). Method sensitivity in this case may be enhanced by the extraction of larger volumes (>1 L) of surface water prior to the immunosorbent step.
Molecularly imprinted solid phase extraction
Molecularly imprinted polymers (MIPs) are synthetic cross-linked polymers that are synthesized in the presence of template molecules (Caro et al. 2003; Jiang et al. 2006). MIPs are easy to prepare, have high thermal and chemical stability, and can selectively rebind target molecules. In some cases, the MIP also recognizes structurally related analytes in the rebinding step, which is known as cross-reactivity. The two main strategies for the preparation of imprinted polymers are grafting of thin MIP films on the surface of porous silica (Sulitzky et al. 2002) and polymerization within the pores of preformed silica beads (Titirici et al. 2003). The latter is a simple method because the reagents are added to the pores and heated to allow the polymerization, which leads to a composite material with the same size and shape as the silica beads.
MIPs have been used as sorbents in molecularly imprinted solid phase extraction (MISPE) mostly in an off-line mode (Berggren et al. 2000; Martín-Esteban 2001; Lai and Wu 2003). Only a few methods have been developed using an on-line mode with MISPE-LC (Masqué et al. 2000; Koeber et al. 2001; Martín-Esteban 2001). For example, Caro et al. (2003) reported a method for the analysis of polar phenols with SPE coupled on-line to LC. Usually, polar phenols cannot be accurately quantified at low levels because the humic substances in the matrix disturb the quantification of most polar compounds. With the polymer of 4-chlorophenol and 4-vinylpyridine as a selective sorbent, the disturbances are removed and a linear response is gained. MIPs have been used in the determination of various pharmaceuticals in biosamples, but only rarely in environmental matrices (Koeber et al. 2001). However, they are reportedly suitable for the analysis of environmental and biological matrices, and trace analysis as well (Jiang et al. 2006).
Extraction of volatile compounds
Numerous techniques, such as LLE and purge-and-trap (PT), are used in the extraction of volatile organic compounds (VOCs) and semi-volatile organic compounds (SVOCs) (Antoniou et al. 2006). In addition, headspace analysis (HS), SPME, closed-loop stripping analysis (CLSA), and capillary membrane sampling-flow injection analysis (FIA) can be used in their extraction. The extraction and concentration steps of VOCs and SVOCs include active sampling by cartridges with sorbent-packed tubes or passive sampling. The analytes can be recovered by solvent extraction or thermal desorption. VOCs and SVOCs are often separated from sludge by the PT method or taken with a gas-proof syringe. They can be separated from wastewater sludge by SPME, which is fast and simple and eliminates the need for solvents. The amount of extraction medium is very small compared to the sample volume.
The extraction of volatile analytes by SPME can be performed using direct immersion (DI) or headspace (HS) techniques. For semi-volatile compounds, DI-SPME seems to be more widely used, while for volatile compounds, HS-SPME is more appropriate (Guimarães et al. 2008). In HS-SPME, the fiber is exposed to the vapor above the solid or liquid sample, while in direct immersion SPME, the fiber is placed directly in the sample (Kotowska et al. 2012). HS-SPME is a multi-phase partitioning system where an equilibrium is reached between the sample matrix and the headspace and also between the headspace and the extracting phase. The isolation process is affected by process conditions such as temperature, pH, and extraction time. On the other hand, VOCs and SVOCs can be extracted by SPME from water samples as well. DI-SPME has been used, for example, for the analysis of organic pollutants such as nitrobenzene, nitrotoluene, and triazines (Kotowska et al. 2012).
The analytes are concentrated in the stationary phase of the SPME fiber, introduced directly into the GC-injector, and thermally desorbed. Antoniou et al. (2006) introduced a fast and simple method using HS-SPME-GC for the determination of halogenated VOCs (e.g., chloroform, bromoform, and chloromethane) in drinking water and wastewater treatment plant effluents. The method is simple and fast, as no complex instrumentation or pretreatment procedure is required, and allows detecting VOCs at ng/L levels. In addition, the method requires no solvent and is inexpensive because the SPME fiber can be used about 60 times.
HS‑SPME is also suitable for the extraction of volatile and semi-volatile organic compounds from wastewater sludge (Kotowska et al. 2012). HS-SPME coupled with GC-MS enables the detection of a wide range of highly volatile (e.g., methanol and acetone) to moderately volatile (e.g., hydrocarbons with more than 20 carbon atoms) compounds. For example, the method is suitable for quantitative analysis of volatile phenolic compounds derived from lignin in aqueous matrices (Kolb et al. 2013). HS‑SPME combines the isolation and concentration of analytes in one stage without the risk of contamination, and only small sample volumes (less than 1 mL) are required. To adapt the extraction step for the needs of quantitative analysis, additional isolation techniques such as sorbent tubes need to be considered.
In addition, a method for the determination of phthalates from water samples was reported (Luks-Betlej et al. 2001). The application of SPME followed by GC-MS in the single ion monitoring mode (SIM) allows the detection of phthalates in drinking water with detection limits in the ng/L range. The method is simple, sensitive, portable, and requires no solvent. In addition, the best repeatability in the extractions is gained using CW–DVB fibers.
On-line extraction
An automated on-line SPE coupled to LC-MS/MS (polar embedded stationary phase C18 + 5 µm PA, mobile phases of water and acetonitrile, mixtures of 0.01% HCOOH in acetonitrile and 0.01% HCOOH in water) has been introduced for analyzing pesticides and their metabolites (Hernández et al. 2001). In particular, when analyzing a group of compounds with varying hydrophobicities, the optimization of conditions with the classical reverse phase sorbents is challenging. The automated on-line SPE is suitable for samples with relatively clean matrices, e.g., surface water, but it remains a challenge to adapt the method for wastewater treatment plant effluents. However, it is one of the most promising techniques for the rapid extraction and preconcentration of most pharmaceuticals.
On-line SPE connected to LC-MS/MS has also been used for the detection of sulfonamides in aqueous samples with excellent detection limits (pg/L). The approach affords full automation and minimum sample handling and requires only low sample volumes (5 to 40 mL, depending on the matrix). In addition, reproducibility, throughput, and sensitivity are improved. Compared to off-line methods, the number of samples analyzed by the on-line method is almost twice as high (García-Galán et al. 2010).
SPME has been used as a sample preparation method, but its throughput has been low because of a lack of suitable extraction phases and automation (Chia and Huang 2005). However, multiple parallel extractions can be performed with the aid of an automated robotic unit, where the amount of analyte extracted by SPME is proportional to the volume of the extraction phase (Vuckovic et al. 2008). For example, a configuration of a robotic autosampler has been reported that enables 96 parallel analyte extractions with detection limits of low ng/mL (Cudjoe et al. 2009).
An automated on-line SPME requires relatively expensive instrumentation (García-Galán et al. 2010). In addition, clogging may occur when handling matrix-rich environmental water samples without prior filtration. Sample pretreatment procedures are often required, which may result in the loss of matrix-bound analytes. To overcome these challenges, a new SPME method with a C18 extraction phase deposited as a thin film (TF-SPME) has been used for the extraction of pharmaceuticals in biological samples. In the TF-SPME, particles are immobilized on a flat, thin, stainless steel surface that allows a larger surface-area-to-volume ratio (Cudjoe et al. 2009). The amount of target analyte extracted with C18 film is improved compared to traditional SPME as a result of a larger volume of the extraction phase in the film geometry. SPME extraction sensitivity is improved because of the film geometry and a higher extraction rate throughput (Togunde et al. 2012).
Commonly, MISPE is used in an off-line mode, but there are a few on-line applications as well (Mena et al. 2002; Caro et al. 2003; Vian et al. 2005; Watabe et al. 2004). In an on-line mode, an MIP column and an analytical column are connected by a column switching system coupled to an HPLC. The MIP column is used for pretreatment to enrich and extract analytes from the sample, while the actual separation is performed in the analytical column (usually a C18 silica column). Compared to the off-line mode, the on-line mode requires no sample manipulation between the pretreatment and analysis steps, which decreases the risk of contamination and loss of analytes. In addition, the consumption of organic solvents is lower, while the reproducibility and the limit of detection (LOD) are improved. However, the sorbents in the pretreatment and analytical columns must be compatible. The column switching system increases the complexity of the HPLC system and the analysis costs. Equivalent methods for on-line sample pretreatment have been proposed, such as immunoextraction coupled to HPLC and atmospheric-pressure chemical ionization mass spectrometry (APCI-MS) (Ferrer et al. 1997) or injection directly to HPLC‑ESI‑MS (Ferguson et al. 2001).
Effect of polarity
There are various challenges in modern aquatic environmental analysis. In addition to the detection of a pollutant, the formation, environmental fate, and bioactivity of its transformation products need to be evaluated (Giger 2009). The transformation products can be more persistent, more (eco-)toxic, and more polar than the parent compounds, resulting in an altered environmental distribution behavior, e.g., a higher mobility in aquatic systems (Sinclair and Boxall 2003).
In an aquatic environment, organic pollutants can be dissolved in water or adsorbed to suspended particles, such as humic substances or sediments (Esteve-Turrillas et al. 2007). However, they are less available to aquatic organisms due to their limited diffusion capability through the cell membrane. The affinity to adsorption of a compound increases with the water temperature and the octanol‑water partition coefficient (Kow). The value of the coefficient increases with increasing lipophilicity. Additionally, the lipophilicity of a compound increases with increasing value of log Kow.
Even though a large part of pollutants are polar, the slightly polar and non-polar compounds still contribute to aquatic pollution (Fischer et al. 2012). For example, pharmaceuticals are commonly designed to be polar (Togunde et al. 2012). Generally, polar compounds are adsorbed by polar materials, such as silanol, which contains polar OH groups. On the other hand, non-polar compounds are well adsorbed by non-polar materials, such as those with octadecyl chains. The detection of polar and non-polar compounds requires different preconcentration methods with different materials, but also different methods of analysis. For example, polar compounds are commonly analyzed by LC-MS or LC-MS/MS (Balakrishnan et al. 2006), while GC is more suitable for slightly polar and non-polar compounds. However, the less volatile compounds and compounds with polar functional groups and active hydrogens often require a derivatization step prior to GC–MS analysis to enhance their volatility (Togunde et al. 2012; Aznar et al. 2014). Recently, two dimensional GC combined with time-of-flight mass spectrometry (TOF MS) has been used for the detection of non-polar and slightly polar pollutants e.g. organochlorine pesticides and chlorobenzenes (Muscalu et al. 2011).
Matrix effects in analyses
Matrix effects depend on the type of matrix and analytes. It has been shown that the most polar compounds are most affected by the matrix (Garcia-Ac et al. 2009). Most likely, the polar compounds are not sufficiently far away from the solvent front, and a more selective analyte extraction and more thorough sample cleanup before injection may be required. For quantitative analysis, the addition of a standard is required to overcome the problems with a changing matrix. The standard should be similar to the analyte and preferably show a similar behavior in the analysis. For example, pharmaceuticals can be determined using similar pharmaceutical compounds as internal standards. However, pharmaceuticals used as standards may also be present in the samples. Thus, chemical compounds not often used in neighboring countries are recommended instead (Van De Steene et al. 2006).
The matrix effect should be evaluated and eliminated as much as possible. A good way to study matrix effects is to use isotopically labeled internal standards (Benijts et al. 2004; Petrović et al. 2005; Taylor 2005) or structural analogues that are not present in the sample. The problem with environmental samples is that there often are a number of compounds present. In addition, different matrices, such as river water and wastewater, have to be examined. In LC-MS/MS analysis, a buffer can be used to reduce possible pH effects. However, concentrations of buffer components should be kept low to keep them from suppressing the signals.
The matrix effect can be suppressed using lower flow rates in LC-MS systems (Van De Steene et al. 2006). Compared to a common flow rate (1 mL/min), a lower 200 µL/min flow rate shows practically no matrix effects. Especially in the ESI mode, if too many compounds are eluted and ionized at the same time, the matrix effect can have an effect on the reproducibility and accuracy. At a lower flow rate, smaller droplets are formed and the total surface area of the droplets increases. Competition between the analyte and matrix components at the droplet surface is reduced, and more analytes can be ionized (Kloepfer et al. 2005).
METHODS OF ANALYSIS
Gas Chromatography
Organic environmental pollutants in aqueous matrices can be divided into categories such as volatile, semi-volatile, nonpolar/lipophilic, polar/hydrophilic, and amphiphilic compounds. Typically, chemicals of a particular group can be determined by the same analytical method. The two most important separation techniques are gas chromatography (GC) and liquid chromatography (LC). Both techniques can be coupled to mass spectrometry (MS) for qualitative and quantitative analysis (Giger 2009). A selection of compound groups detected in different environmental matrices, e.g., in surface and wastewaters, and their analysis methods based on GC are described below and finally summarized at the end of this chapter in Table 1.
Antibacterial agents
Many compounds found in aqueous samples can be analyzed by GC-MS. The antibacterial agent triclosan (TCS) and its transformation product methyltriclosan (MTCS) are monitored worldwide in a variety of environmental samples such as influents and effluents of municipal wastewater, surface waters, and sediment samples. Generally, TCS and MTCS in aqueous and solid samples can be analyzed, for example, by LLE or SPE combined with LC-MS/MS or GC‑MS with electron impact ionization (EI) or electron-capture negative ionization (ECNI) techniques. For example, TCS in municipal wastewater effluents can be pretreated by reversed phase C18 SPE, derivatized with tert-butyldimethylsilyl (TBDMS), and analyzed by GC-MS with the detection limit of 1 ng/L (Cheng et al. 2011).
Derivatization must be performed to increase the volatility of TCS and achieve high resolution in GC-MS analysis. Silylation is a common derivatization procedure. Cantwell et al. (2010) compared two silylation reagents, N-methyl-N-(trimethylsilyl)-trifluoroacetamide (MSTFA) and N-(tert-butyldimethylsilyl)-N-methyltrifluoroacetamide (MTBSTFA), and found that the latter yields a stable TBDMS-TCS product and a good separation from MTCS. However, derivatization with diazomethane or silylation reagents such as TBDMS or pentafluorobenzoate (PFBA) can be laborious and time-consuming. Cheng et al. (2011) showed that direct injection-port derivatization of various organic pollutants reduces solvent waste and simplifies sample preparation. Additionally, to improve detection sensitivity, a large-volume sample injection device can be used.
Benzothiazoles and benzotriazoles
Benzothiazoles (BTHs) and benzotriazoles (BTRs) are water-soluble compounds used as biocides, corrosion inhibitors, and vulcanization accelerators in rubber production, to name but a few (Fig. 1). They are resistant to biodegradation and only partially removed in wastewater treatment (McNeill and Cancilla 2009) and thus widely distributed in municipal and industrial wastewaters. BTHs and BTRs also can be determined by GC coupled to electron impact mass spectrometry (EI-MS), but the procedure suffers from interference caused by the complex matrices.
Fig. 1. Molecular structures of benzothiazole (BTH), benzotriazole (BTR), and 2-hydroxy-benzothiazole (OHBTH)
Often, LC-MS or LC-MS/MS is used for the determination of BTHs and BTRs in environmental samples, but ionic suppression in the electrospray ion sources may occur due to charge competition with compounds provided by the matrix (Giger et al. 2006). To overcome this problem, BTHs and BTRs can be determined by GC-MS or by two‑dimensional -TOF MS (Jover et al. 2009). However, analysis by GC-MS with conventional polar columns may suffer from column bleeding, where a small amount of diagnostic ions can coelute with coextracted compounds.
Alternatively, BTHs and BTRs can be determined by GC-MS from environmental matrices using ionic liquids (ILs) as a stationary phase (Dominguez et al. 2012). ILs have been applied as a stationary phase in GC-MS analysis and in two‑dimensional (Purcaro et al. 2010). They have been used in several applications, such as separation of fatty acids and their methyl esters (Delmonte et al. 2011).
ILs have become interesting because of their unique physicochemical properties (Tobiszewski et al. 2009). Room-temperature ILs are commonly composed of asymmetrically substituted organic, nitrogen-containing cations such as imidazole, pyrrolidine, or pyridine with inorganic anions (e.g., Cl‑, PF6‑, BF4‑). The properties of ILs often include low volatility, high viscosity, and good thermal stability (Sun and Armstrong 2010).
In addition, ILs can separate both polar and nonpolar compounds (Ding et al. 2004; Sun et al. 2011) and provide increased unique selectivity and high efficiency in the determination of complex mixtures (Bianchi et al. 2011). The high selectivity is caused by the resolution of polar compounds from non-polar ones, which is useful when analyzing complex mixtures of both (Sun et al. 2011).
Nitrosamines
Nitrosamines (NAs) belong to the nitrogen-containing disinfection by-products whose main generation source is the final disinfection of drinking water, especially when chloramines are employed as the disinfectant agent (Wang et al. 2011). NAs such as caffeine (CAF) are polar compounds, and they are usually water-soluble and difficult to extract with organic solvents. Caffeine is metabolized in mammals by N-methylation to dimethylxanthines. The non-metabolized substances are mostly excreted in urine as unchanged substances that can be found in wastewater treatment plant effluents (Halling-Sorensen et al. 1998). The contaminants found in the environment are often highly polar and cause low selectivity when analyzed with low-polarity stationary phases which result in high background noise with polar GC-MS columns (Reyes-Contreras et al. 2012). Depending on the compound, detection limits of 19.5 to186 ng/L have been achieved.
For the detection of NAs, analytical methods, such as GC coupled to a thermal energy analyzer (TEA) (Vieira et al. 2006), nitrogen phosphorous detector (NPD) (Calderón-Preciado et al. 2011), MS (Grebel et al. 2006), MS/MS (Munch and Bassett 2006), and high-resolution mass spectrometry (HRMS) (Planas et al. 2008) have been used. Commonly, the GC columns used for these analyses are made of cyanopropylphenyl dimethyl polysiloxane, trifluoropropyl methylpolysiloxane, polyethylene glycol, or diphenyl dimethyl polysiloxanes. Alternatively, ILs can be used as a stationary phase. ILs as stationary phases in GC-MS analysis have been reported as suitable for the detection of NAs and CAF metabolites in wastewater samples (Reyes-Contreras et al. 2012). CAF and other NA metabolites can also be quantified by GC–MS/MS from wastewater and ground water samples. For the analysis of CAF metabolites, ionic liquid stationary phase SLB-IL59 (1,12-di(tripropyl-phosphonium)dodecanebis (trifluoro-methylsulfonyl) imide) provides elution with the highest peak symmetry in an acceptable analysis time.
Amines
The analysis of amines with common analytical techniques is often difficult because of their basic character and because highly polar amines are not easily extracted from the polar water matrix (Baltussen et al. 1998). The amino group induces a large dipole moment, which is responsible for a strong interaction with silanol groups and siloxane bridges in the stationary phase of the GC capillary column. As a result, nonlinear adsorption effects and strong tailing peaks in the chromatogram may occur. To prevent this, the amines need to be derivatized. The derivatization reagent is selected on the basis of the derivatized functional group and other functional groups in the molecule (Knapp 1979). Acylation, alkylation, and silylation can in principle be used in the derivatization of amino groups contained in alkyl amine structures.
Primary alkyl amines are often determined with GC and derivatized with pentafluorobenzoyl chloride (Baltussen et al. 1998) or with pentafluorobenzaldehyde (Ngim et al. 2000). In addition, acetyl and trifluoroacetyl derivatives can also be used (Knapp 1979). However, long-chain primary alkyl amines can be determined by GC with simultaneous FID or NPD as well as GC-MS. Trifluoroacetylated derivatives of tert-octadecylamines in water samples can be quantitatively determined with GC coupled to FID or NPD. Long-chain primary alkyl amines can be determined with GC‑MS, GC‑FID, or GC‑NPD after derivatization with trifluoroacetic anhydride (TFAA) (Kusch et al. 2006). Silylation with N-methyl-N-(trimethylsilyl)trifluoroacetamide (MSTFA) is not suitable, but acylation with trifluoracetic anhydride (TFAA) converts active hydrogen sites (‑NH, -OH, -SH) into amides, esters or thioesters.
Steroids
Steroid estrogens can be determined by GC-MS, but their derivatization to more volatile forms is required and the detection limits often remain above the ng/L level. Because the levels of estrogens are likely to be low in the aquatic environment due to dilution, degradation, and sorption, sensitive analytical techniques are required to determine their concentration levels. More sensitive results can be obtained by GC-MS/MS, but a derivatization step is still needed (Huang and Sedlak 2001).
For the derivatization of steroid pollutants, samples are often labeled by a hydroxyl group, neglecting a full derivatization, such as oximation of steroids’ keto group(s) (Kolpin et al. 2001; Andrási et al. 2011b). Bis-(trimethylsilyl)-trifluoroacetamide (BSTFA) is the most frequently applied derivatization reagent. However, it is reported to show considerably lower responses compared to N‑methyl-N-(trimethylsilyl)-trifluooacetamide (MSTFA) and hexamethyldisilazane combined with trifluoroacetic acid (HMDS+TFA) reagents with certain steroids such as androsterone and norethisterone (Andrási et al. 2011a).
Steroid hormones in municipal wastewater samples can be extracted by SPE and analyzed with GC‑MS (Esperanza et al. 2004), but they need to be derivatized by reacting with TMCS and BSTFA before injection into the GC‑MS system (Keith et al. 2000). Steroid hormones can be analyzed in the SIM mode, which allows detection at the low ng/L range (Sowers et al. 2009). On the other hand, it has been shown that concentrations of steroid hormones in wastewaters can be much higher (Martinović et al. 2007; Tan et al. 2007).
Volatile compounds
During a biological sewage treatment process, various volatile organic compounds (VOCs) and semi-volatile organic compounds (SVOCs) formed in the metabolism of microorganisms may escape to the atmosphere. VOCs and SVOCs are harmful to humans and the environment. Some of them degrade during the sewage treatment, while others remain unchanged. The main VOCs include n-alkanes, branched, cyclic, and unsaturated aliphatic hydrocarbons, aromatic hydrocarbons, and halogenated aliphatic hydrocarbons. The most odorous VOCs include dimethyl sulfide, limonene, and α‑pinene. The SVOCs consist of aromatic hydrocarbons, phthalic acid esters, chlorobenzenes, nitroaromatic compounds, and phenols (Kotowska et al. 2012).
VOCs in environmental samples are usually analyzed by GC‑MS, GC‑FID, or by coupling GC with triple quadrupole mass spectrometry (QqQ-MS/MS) (Guimarães et al. 2008; Kotowska et al. 2012). By means of MS/MS, adequate precursor and product ions can be selected. In most cases, the use of MS/MS improves the sensitivity and the signal-to-noise ratio. Selected reaction monitoring (SRM) mode with two MS/MS transitions gives the possibility of simultaneous confirmation and quantification.
HS-SPME followed by GC-QqQ-MS/MS is a rapid method for the determination of VOCs (e.g., chloroform, benzene, toluene, xylene) in environmental and wastewater samples (Cervera et al. 2011). GC-MS (SIM) and GC-MS/MS (SRM) are both suitable for their determination, but the specific ions cannot be measured in the SIM mode at low concentration levels. On the other hand, a fully automated method for determining aliphatic primary amines in wastewater, such as methylamine, ethylamine, and cyclohexylamine, is based on the simultaneous derivatization with pentafluorobenzaldehyde (PFBAY) and HS-SPME, followed by GC and ion trap tandem mass spectrometry (GC-IT-MS/MS) (Llop et al. 2010).
Table 1. Examples of GC Analysis Sequences of Selected Compounds and Compound Groups Found in Environmental Matrices
Liquid Chromatography
LC-MS/MS has been widely used because of its high sensitivity and selectivity. It is suitable for the determination of a wide range of polar and amphiphilic compounds. Because pharmaceuticals are often polar and non-volatile, they can be analyzed by LC without derivatization. Combined with MS/MS, detection limits of 2 to 13 ng/L can be reached (Togunde et al. 2012). Many other semi- or non-volatile classes of organic compounds, such as peptides, proteins, and polycyclic aromatic hydrocarbons, are easier to analyze by LC instead of GC. In addition, excellent selectivity and sensitivity can be achieved by multiple reaction monitoring techniques in tandem or multistage quadrupole and ion-trap spectrometry (MS/MS, MSn), which enables the determination of trace compounds in complex mixtures (Giger 2009).
Endocrine-disrupting chemicals (EDCs) are a group of compounds such as natural and synthetic steroid hormones, phthalates, alkylphenols, phytoestrogens, pesticides, surfactants, and polychlorinated biphenyls (Routledge and Sumpter 1997; Clouzot et al. 2008). They are known to induce endocrine disturbances and have antagonistic or agonistic properties. EDCs enter the environment from various sources, such as wastewater effluent, agricultural runoff, and landfills. Compounds of interest, such as pharmaceuticals and EDCs, are often present in surface and wastewaters at trace or ultra-trace levels; thus, sensitive analytical methods are required for their detection. A selection of commonly detected pharmaceuticals in environmental samples is presented in Fig. 2, and examples of sequences for analyzing pharmaceuticals, steroid hormones, and other organic compounds found in environmental matrices are summarized at the end of this chapter in Table 2.
Fig. 2. Molecular structures of selected anti-inflammatory, analgesic, and antibiotic drugs
Pharmaceuticals
Pharmaceuticals are widely used as human and veterinary drugs and are commonly excreted in urine or feces discharged into wastewaters (Golet et al. 2001). Pharmaceuticals and their metabolites enter the environment primarily via wastewater treatment effluents and sludges (Ternes 1998a; Ternes et al. 2005). Their transformation processes vary depending on the composition of sewage and the design and operation of the treatment process (Johnson and Sumpter 2001; Roberts and Bersuder 2006). Even though only scant information is available on the behavior of pharmaceuticals in wastewater treatment (Carballa et al. 2004), it has been shown that many pharmaceuticals are not completely removed. This results in their occurrence in effluents, rivers, and lakes, and some of them may remain in the environment for extended periods of time (Carballa et al. 2004; Roberts and Bersuder 2006).
Previously, pharmaceuticals such as sulfonamide drugs have been analyzed by HPLC with photo diode array (PDA) detection (Horie et al. 1990), but also by GC-MS (Carignan and Carrier 1991), GC-MS/MS (Matusik et al. 1990), and GC with electron-capture detection (ECD), or thin-layer chromatography (TLC) (Unruh et al. 1990). The enriched wastewater matrix has been found to be too complex for UV detection; tandem mass spectrometry has been shown to be more suitable. Pharmaceuticals such as sulfamethoxazole and sulfadiazine can be analyzed with HPLC-MS in the SIM or SRM mode. SIM is more sensitive than SRM, but it is not as selective (Niessen 1998; Hartig et al. 1999).
In analyses of pharmaceuticals in environmental water matrices, HPLC coupled with positive-ion ESI-MS/MS is the method of choice (Hartig et al. 1999). An analytical C18 column and a guard column are recommended, coupled with MS/MS detection in the positive or negative ionization mode, depending on the compound. The method shows good reproducibility, sensitivity, and selectivity and attains a low (ng/L) detection range (Roberts and Thomas 2006).
Analgesics and antibiotics are primarily analyzed by LC-MS/MS, and only in some cases by GC-MS/MS after derivatization with TBDMS (Lee et al. 2005). However, it is better to avoid derivatization when the thermal stability of the studied compound is unknown. HPLC-MS and HPLC-MS/MS have been used in the determination of pharmaceuticals in surface water, wastewater, and groundwater (Stackelberg et al. 2004; Roberts and Bersuder 2006). Acidic pharmaceuticals have previously been detected by GC-MS, but recently, LC-MS methods with ESI have become more important. Also, the most polar compounds and their metabolites can be analyzed by LC-MS with low (ng/L) detection limits (Deng et al. 2003).
Anti-inflammatory drugs can be analyzed by immunoassays, but suitable antibodies are still required for most pharmaceuticals (Deng et al. 2003). Their transformation products and metabolites are often more polar and water-soluble than the parent compounds. Because low concentrations require preconcentration and extraction, highly polar compounds in aqueous samples are challenging to analyze (Zwiener 2007).
SPE-HPLC combined with QqQ-MS/MS is a precise method for the determination of pharmaceuticals with long environmental persistence or high potential toxicity, such as estrogens and anti-cancer drugs (Castiglioni et al. 2005). SPE is performed with a mixed-mode cation exchange (MCX) and a mixed reversed phase-cation exchange cartridge in which the strong cation exchanger sulfonic acid groups are placed on the surface of a poly-divinylbenzene-co-N-vinylpyrrolidone copolymer. Because the cation-exchanger binds basic, ionized compounds, and the reversed phase binds both acidic and neutral compounds, all acidic, neutral, and basic compounds can be extracted. An HPLC system with a C8 column is employed for the analysis and detection with a turbo ion spray source in the range of ng/L to µg/L.
Steroid estrogens
The sex hormones (natural and synthetic estrogens (Fig. 3), testosterone, progesterone, and androstenedione), like other EDCs, have frequently been detected in sewage waters (Beck et al. 2006), from which they often end up in lakes and rivers (Baronti et al. 2000).
Fig. 3. Molecular structures of natural and synthetic estrogens; estrone (E1), 17β-estradiol (E2) estriol (E3), and 17α-ethynyl-estradiol (EE2)
Synthetic EE2 is engineered from the natural hormone E2. It is more resistant to biodegradation than the natural E2. According to Johnson and Williams (2004), 43% of EE2 is expected to be metabolized in the human body, 27% is excreted as conjugated molecules, and 30% is in the free form. Biological treatments are suitable for the removal of organic matter such as ECDs, while the activated sludge process removes 75% of natural estrogens and EE2. It has been reported that up to 75% of the natural estrogens are mineralized, but the degree of mineralization of EE2 is considerably less (Layton et al. 2000). On the other hand, testosterone, androstenedione, and progesterone can be completely removed during biological wastewater treatment (Esperanza et al. 2004). In addition, almost all of the estradiol and more than half of the E1 and E2 can be removed. E2 also generates E1 as an intermediate product when degrading, which increases the amount of E1 detected in the final effluents.
Even though the concentrations of hormones in the aquatic environment are low (low ng/L range), they largely contribute to the estrogens of surface waters (Desbrow et al. 1998). For example, EE2 is a contraceptive compound that causes feminization of fish even at low (ng/L) concentration levels (Clouzot et al. 2008). The occurrence of EE2 in the aquatic environment comes from WWTP effluent due to insufficient purification. Different treatment processes have been tested for the removal of EE2, such as photodegradation (Liu et al. 2003), granulated activated carbon, MnO2, sand reactor (Rudder et al. 2004), and ozonation (Huber et al. 2004), but they were shown to be inadequate.
In sewage treatment plants, estrogen conjugates undergo chemical or enzymatic dissociation and re-form active estrogens (Ternes et al. 1999). There are low concentrations of estrogen glucuronides in sewage waters compared to corresponding free estrogens (Isobe et al. 2003). This suggests that glucuronides are degraded prior to reaching the sewage treatment plant. In addition, acidic pH prevents the dissociation of steroidal conjugates to free steroids. Methods such as isotopically labeled surrogates are needed to identify conjugates of steroid hormones, pharmaceuticals, and other compounds that may transform and are released into wastewaters and surface waters (Reddy et al. 2005).
The lowest concentrations of EE2 are often below the LODs (< 2 ng/L), which limits the evaluation of its removal during wastewater treatment (Laganà et al. 2004). However, reductions from 37% to 87% between influents and effluents have been measured (Johnson et al. 2000; Cargouet et al. 2004; Laganà et al. 2004), and 60 to 80% of EE2 is adsorbed on sludge during the activated sludge process. Chemical treatment such as precipitation is inefficient for the removal of EE2. The removal of EE2 is dependent on the sludge retention time (SRT). The higher the SRT is, the more efficiently EE2 is biodegraded. This synthetic hormone is much more resistant to biodegradation than natural ones, but its highly hydrophobic nature makes sorption a significant removal factor in WWTPs (Clouzot et al. 2008).
Salste et al. (2007) concluded that it is not only estrogens E1, E2, and EE2 that account for estrogenic activity in wastewater effluents. Their often detected low concentrations account for a low percentage of the whole activity. However, other studies (Aerni et al. 2004; Beck et al. 2006) have shown that natural estrogens are the major causes of estrogenic activity in surface and wastewaters. Even though there are synthetic non-steroidal compounds such as nonylphenol, phthalates, and animal sterols in wastewater effluents, their estrogenic activity is several orders of magnitude lower than that of estrogens, and they are not therefore likely to account for the residual activity (Fernandez et al. 2007). In addition, Björkblom et al. (2008) suggested that the activity observed may be due to the synergy of detected compounds when detected as a mixture.
Several analytical methods, such as GC-MS and HPLC-MS, have been employed for the detection of steroid estrogens in environmental samples. However, only a few methods are suitable for quantifying steroid conjugates in wastewaters (Pojana et al. 2004). The analysis of estrogen conjugates has mostly focused on applications with biological fluids instead of wastewater samples with more complex matrices (Gentili et al. 2002; Isobe et al. 2003).
The first method in the analysis of hormones was radioimmunoassay (RIA), which has been used for the detection of E2 and EE2 with detection limits of 0.1 to 0.05 ng/L (Snyder et al. 1999). However, compounds structurally similar to the analytes are prone to interfere. In addition, an enzyme-linked immunosorbent assay (ELISA) based on an enzymatic reaction has been reported (Huang and Sedlak 2001). Even though it has an excellent sensitivity (0.1 ng/L), it can suffer from interference of a complex matrix if proper purification is not performed prior to analysis (Almeida and Nogueira 2006).
HPLC is considered more suitable than GC-MS for the detection of estrogens and their derivatives because of a less expensive detector and lower maintenance costs, even though polar interference may occur with environmental samples. In addition, a derivatization step is usually needed prior to the GC-MS analysis. However, the hydroxyl group at C17 of EE2 is difficult to silylize, and EE2 may convert to estrone, resulting in an overestimation of E1 and underestimation of EE2 (Shareef et al. 2004). Sulfate derivatives of steroid estrogens cannot be analyzed directly by GC-MS, but they must first be dissociated to free estrogens, chemically or enzymatically. However, the hydrolysis of estrogen conjugates may not be efficient enough, and uncontrolled losses of free steroids may occur. In addition, hydrolysis based on enzymes may not act on all forms of conjugates. To overcome these issues, steroid conjugates have been analyzed by HPLC-MS/MS (Zhang and Henion 1999).
Because of the complex matrices, it is challenging to avoid a loss of target analytes during extraction of EE2. Soxhlet extraction with methanol-acetate (1:1) gives above 70% recoveries, and with ethyl acetate, the recovery rate is over 95%; however, Soxhlet extraction is time-consuming and requires large quantities of solvent (Ying and Kookana 2003). Recently, SPME has been considered a good alternative to SPE due to its higher recovery and accuracy. When longer monitoring is needed, passive samplers appear as promising tools to quantify EE2 because of their lower LODs and ability to take temporal variations into account (Mitani et al. 2005). For analyses of EE2 in WWTP effluents, LC‑MS is often used to gain low LOD. The lowest LODs are obtained with tandem mass spectrometry, which is better adapted to environmental matrices.
Highly sensitive (0.1 to 5 ng/L) estrogen analysis can also be achieved using LC with APCI-MS/MS detection. It is an attractive method because no derivatization step is required (Laganà et al. 2000). However, the instrumentation is expensive, and its application to environmental monitoring is not yet in routine use (Ferguson et al. 2001). In addition, steroid estrogens and their glucuronide and sulfate conjugates in sewage influents have been measured by HPLC-ESI-MS/MS (Reddy et al. 2005). The purification can be performed by SPE and separation by diethylaminoethanol anion exchange chromatography (DEAE). Natural and synthetic derivatives of estrogenic compounds in municipal and industrial wastewaters can also be detected by HPLC-ESI-MS in the ng/L range (Pojana et al. 2004). The method requires extraction with SPE on a C18 cartridge followed by HPLC with a C8 column coupled with MS via an electrospray interface. On the other hand, estrogens E1, E2, EE2, and E3 have been determined with LC-MS/MS from wastewater effluents (Björkblom et al. 2008).
Because the concentrations of diverse target steroid compounds in environmental samples are low and combined with complicated matrices, robust in vitro methods are needed. In vitro yeast estrogen screen assays can be used for the determination of estrogenic activity in environmental samples because they respond to all receptor-mediated estrogenic activity, regardless of chemical structure (Campbell et al. 2006). For identification of specific estrogenic compounds, the results of biological assays must be combined with GC-MS or LC-MS analyses. For example, the estrogenic activity of SPE (Oasis HLB) concentrated steroid estrogen in municipal wastewater samples has been determined with bioluminescent yeast assays and with LC-MS/MS (Salste et al. 2007). Significant differences in estrogenic activities have been reported (Furuichi et al. 2004) when combining the results of chemical analysis and biological assays. However, Salste et al. (2007) reported that the results were in good agreement with those of chemical analysis.
Illicit drugs
Residues of illicit drugs can be found in municipal wastewater and surface waters (Jones-Lepp et al. 2004). Illicit drugs found in the environmental media are the most widely used ones, such as cannabinoids, amphetamines, opioids, and cocaine. The molecules found in environmental media are mostly urinary excretion products, unchanged parent drugs, or their metabolites (Castiglioni et al. 2008).
GC-MS and LC-MS are considered most suitable when quantitative analysis of illicit drugs is needed (Kraemer and Paul 2007). Because the amounts of residues are expected to be low, LC-MS offers the needed selectivity and sensitivity (Castiglioni et al. 2008). Amphetamine, opiates, cocaine, cocaine metabolites, and cannabinoids can be simultaneously extracted by liquid/liquid separation, derivatized, and analyzed with GC-MS. Also, HPLC analyses can be improved by derivatization. For example, primary alkyl amines can be derivatized with, e.g., 1-fluoro-2,4-dinitrobenzene (van der Horst and Holthuis 1988) or salicylaldehyde diphenylboron chelate (Class et al. 1986) before HPLC analysis. On the other hand, amphetamines and other hypnotics can be extracted by SPE followed by LC-MS/MS analysis (Bogusz et al. 2000), which allows the simultaneous detection of several drugs (Castiglioni et al. 2008). Other methods have been introduced as well, such as GC coupled with chemical ionization (CI-MS) and ion-trap mass spectrometry (IT-MS).
Surfactants
Conventional surfactants are degraded to a great extent in the biological wastewater treatment process, but poly- or perfluorinated surfactants (PFS) are stable against biodegradation and oxidation agents. Because PFS compounds are stable also in advanced oxidation processes, physical methods, such as adsorption or membrane treatment, are the most promising options for their removal (Schröder 2003; Berger and Haukås 2005). Fluorinated surfactants can be almost completely (78 to 99%) removed from wastewater by separation and adsorption on, e.g., activated sludge or granulated activated carbon (GAC) (Schröder et al. 2010). However, the disposal of sewage sludge in an environmentally friendly way still needs to be addressed.
The degradation of surfactants can be monitored by HPLC combined with HRMS or MS/MS. Extraction and concentration can be performed with SPE and LC separation with a precolumn combined with a reversed phase C18 column. Anionic perfluorinated surfactants, e.g., perfluorooctanoic acid (PFOA) and perfluorooctanesulfonic acid (PFOS), can be easily determined with high-resolution LC coupled to MS. Degradation products can be determined using MS/MS in a collision-induced dissociation (CID) or high-energy collision dissociation (HCD) mode (Schröder et al. 2010).
Other groups of compounds
Resin acids and pimaranes are found in the wood and bark of conifers. They are tricyclic, diterpenic carboxylic acids that act as a natural antimicrobial defense system in trees. When municipal wastewater treatment is integrated with the treatment plant of a pulp mill, resin and fatty acids may also be present in the receiving water body. It is believed that resin acids contribute most of the overall toxicity of typical pulp and paper effluents (Zender et al. 1994; Valto et al. 2012). They can accumulate in fish and affect their reproduction. In addition, toxic effects have been observed even at low concentrations (20 µg/L) of resin and unsaturated fatty acids (Kostamo et al. 2004; Valto et al. 2012). HPLC-ESI-MS is a fast, highly sensitive method for the quantitative analysis of resin acids and pimaranes in river waters (McMartin et al. 2002). It is suitable for the analysis of resin acids when isomeric speciation is not required. However, the resin acid isomers cannot be separated under the conditions used in HPLC, which cannot be recommended for the environmental monitoring of resin acid isomers.
Resveratrol is a polyphenol with strong anti-oxidative properties. It belongs to a group of phytoalexins that are produced in plants during environmental stress, such as insect or pathogenic attack. They exist as a glycon in wine and are called piceid when bound to glucoside. There are numerous methods to determine the resveratrol derivatives, such as SPE or direct injection followed by GC, HPLC (Chu et al. 1998), or capillary electrophoresis (McMurtrey et al. 1994). However, most GC methods require a derivatization step to increase the volatility, which is time-consuming and may alter the target compound, for instance by converting the trans to the cis form (Trela and Waterhouse 1996). The most appropriate method for the separation of cis– and trans-resveratrol is an RP18 column with diode array detection (Adrian et al. 2000), but it requires a relatively long analysis time (Martínez-Ortega et al. 2001). Piceid isomers and cis– and trans‑resveratrol can be analyzed by direct injection of the sample, followed by an HPLC step with two monolithic columns (Vian et al. 2005). A monolithic column operates at a higher flow rate than a conventional reverse phase column and thus gives shorter washing and re-equilibration times. The molecules can be separated in a single run without a purification step.
HPLC has been used for the detection of pesticides such as DDT. For example, DDT can be extracted from water samples by SPE followed by reverse phase HPLC analysis with UV detection (Asi et al. 2008). The method provides detection of DDT and its various metabolites (o,p´‑DDD, o,p´‑DDE, o,p´‑DDT, p,p´‑DDD, p,p´‑DDE, and p,p‑DDT) at ng/mL levels.
Table 2. Selection of LC Analysis Sequences of Pharmaceuticals, Steroid Estrogens, and Other Compound Groups Found in Environmental Matrices
Phthalates such as dibutyl phthalate (DBP) and di-(2-ethylhexyl) phthalate (DEHP) have been determined from sludge and sediment samples by SPME (CW–DVB fibers) followed by HPLC‑ESI–MS (Möder et al. 1998). Diethyl phthalates have also been extracted by SPME (with CW–TPR and PDMS‑DVB fibers) and analyzed by HPLC-UV (Kelly and Larroque 1999). Phthalates and an adipate ester have also been extracted by SPME (PA fiber) and analyzed by GC–MS (Peñalver et al. 2000).
Detection
The most commonly used ionization methods are atmospheric pressure chemical ionization (APCI), electrospray ionization (ESI), and atmospheric pressure photoionization (APPI) when analyzing, for example, pharmaceuticals with HPLC or UPLC coupled to MS (Cahill et al. 2004). In the APPI system, a photon beam is created by a high-intensity discharge lamp, with the vapors of a nebulized solution entering the MS source (Marchi et al. 2009). This technique can ionize compounds with various polarities regardless of matrix compounds. It has been successfully applied in the analyses of environmental and pharmaceutical samples (Viglino et al. 2008).
ESI and APCI have been the most widely used methods for analyses of polar molecules (Cahill et al. 2004; Castiglioni et al. 2005) in spite of their limitations. Because ionization efficiencies depend on charge affinity, some nonpolar compounds (e.g., PAHs) are difficult to ionize. During ESI, cations such as Na+ and K+ are formed, which can increase the chemical background noise (Hanold et al. 2004). Target molecules may not ionize if there are competing compounds present in the sample. Therefore, chemical derivatization has been used to increase sensitivity, even in the case of LC-MS analysis (Palmgrén et al. 2005).
GC-MS, LC-MS, and inductively coupled plasma mass spectrometry (ICP‑MS) coupled with different separation and extraction methods have been used in the analysis of environmental samples (Richardson 2004). In addition, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) is suitable for characterizing biomolecules, polymers, and compounds with a high molecular weight, such as humic substances (Gajdošová et al. 2003). It has been used for fingerprinting analysis and the sequencing of protein biomarkers (Stump et al. 2003). However, the detection of small molecules in organic matrices is difficult due to detector saturation.
For highly polar compounds such as paraquat and cacodylic acid, very low (pg/L) limits of detection can be reached. MALDI-TOF-MS has mostly been used for qualitative analysis of high-molecular weight compounds, but there are also methods for low-mass compounds (Guo et al. 2002). For a quantitative analysis, an isotope-labeled analyte molecule or one structurally analogous to the analyte can be used as an internal standard. MALDI-TOF-MS is a rapid and simple method for quantitative analysis compared to GC and HPLC. Because of its high throughput, it is suitable as a screening method in environmental pollutant monitoring when handling large amounts of samples.
Carbon nanotubes as a matrix for MALDI-TOF-MS eliminate the background ion interference and offer a method for the detection of low-mass compounds (Xu et al. 2003). However, carbon nanotubes are poorly soluble, which leads to poor resolution and reproducibility of low-mass analytes. In addition, their impurities can interfere with their function as energy receptacles and transporters (Pan et al. 2005). Oxidized and purified carbon nanotubes are water-soluble, and simpler handling procedures with good reproducibility are available. Hu et al. (2005) reported a MALDI-TOF-MS method for analysis of low-mass compounds in environmental samples. In particular, highly polar chemicals can be measured with high sensitivity. In addition, the method has relatively high tolerance for interfering molecules, and only a simple pretreatment, or none at all, is needed before MS detection.
Cationic surfactants are surface-active compounds with one or several hydrophobic alkyl chains and a hydrophilic group with a positive charge. Previously, they were determined by capillary electrophoresis (CE) (Piera et al. 1997), HPLC (Radke et al. 1999; Norberg et al. 2000) or GC (Ding and Tsai 2003) from environmental and industrial samples. However, the methods require large quantities of reagents, are time-consuming, and often need derivatization and chromatographic separation of quaternary ammonium surfactants before analysis. In addition, cationic surfactants form micelles and are strongly adsorbed on the capillary surface, which leads to peak tailing and insufficient separation by the CE method.
MALDI-MS has been used for the investigation of large molecules such as proteins (Sudhir et al. 2005), nucleic acids (Gut 2004), drugs (Sekar and Wu 2006), and synthetic polymers (Marie et al. 2000). The analysis of small molecules is difficult because of the interference caused by the matrix ions in the m/z range below 500 Da. However, Shrivas and Wu (2007) reported that cationic surfactants including cetyltrimethyl ammonium bromide (CTAB) and cetylpyridinium chloride (CPC) can be determined from river and municipal wastewater by single-drop microextraction (SDME) with atmospheric pressure/matrix-assisted laser desorption ionization mass spectrometry (AP-MALDI-MS) without pre- or post-treatment or separation by HPLC, GC, or CE. Even with river and municipal wastewater samples, a clean spectrum can be obtained by SDME followed by AP-MALDI-MS (Shrivas and Wu 2007). Intense unwanted peaks and interferences arise without SDME, caused by the matrix or suspended materials. SDME coupled to AP-MALDI-MS gives results comparable to hollow fiber-based liquid-phase microextraction (HF-LPME).
Tandem mass spectrometry
Numerous analytical methods have been used for analyzing pharmaceuticals from aqueous environmental matrices. Mass spectrometry has traditionally been used to measure substances in biological fluids, but residues of illicit drugs can also be found in urban wastewater and river water. Because of the complex matrices of environmental samples, LC-MS/MS is often the most suitable method for the analysis. For example, cocaine and its metabolites have been measured from urban wastewater treatment plants with this technique (Castiglioni et al. 2008). When compounds such as synthetic steroids and cholic acids are identified and quantified with GC-MS/MS, multiple reaction monitoring (MRM) gives the best selectivity and sensitivity compared to full scan (FS), multiple ion monitoring (MIM), and selective ion monitoring (SIM) (Andrási et al. 2011b).
For the analysis of pharmaceuticals such as bezafibrate, methotrexate, and orlistat, ESI is the best ionization source for LC-MS/MS (Garcia-Ac et al. 2011). Protonated target molecules can be detected with a higher relative abundance by ESI compared to APPI or APCI. In addition, it provides better detection limits, increased signal-to-noise ratios, and higher peak areas. Using flow injection analysis (FIA), about 95% higher signal intensities can be obtained. In the presence of a complex matrix, ESI gives about an 80% higher signal compared to APPI and APCI.
In the LC-MS/MS analysis of pharmaceuticals in wastewater samples, the magnitude of the discharge current of the APCI corona needle does not significantly affect the appearance of the mass spectra, but it has an effect on the intensity of the ion peaks. As stated earlier, (Hanold et al. 2004) and Garcia-Ac et al. (2011) found that the addition of a photoionizable substance such as toluene to the LC flow can increase the ionization yield of the target compounds and enhance the signal intensity. It can also increase the background noise and decrease the signal-to-noise ratio. The signal-to-noise ratio and the peaks gained by ESI are higher than those with APPI and APCI. In addition, when using on-column ESI, the peak areas of all analytes are higher than those with APPI and APCI. The same trend can be observed when using FIA compared to on-column analysis.
The current understanding about the identity and quantity of transformation products from biocides and pharmaceuticals is fairly limited because there are only a limited number of reference standards for the many plausible transformation products. One recently introduced analytical tool is high-resolution tandem mass spectrometry (HR-MS/MS), including ion trap-time of flight (IT-ToF) or linear ion trap-orbitrap (LTQ-Orbitrap). These techniques provide highly sensitive detection and accurate mass measurements and are thus suitable for the structural elucidation of analytes at low concentrations (Krauss et al. 2010). An ion trap tandem-in-time mass spectrometry detection system can perform simultaneous quantitative analysis and characterization of trace level compounds. Compared to single MS, MS/MS increases the selectivity of the determinations in complex matrices such as wastewater (Llop et al. 2010). In addition, studies of capillary electrophoresis coupled with MS, MS/MS, and MS/MS/MS have been reported (Bateman et al. 1997).
Finally, Kern et al. (2010) reported a method for the detection and analysis of transformation products from the degradation of different pharmaceuticals and biocides such as atenolol, bezafibrate, ketoprofen, metoprolol, and venlafaxine. The method is based on HR-MS/MS followed by quantitative analysis. The suggested procedure captures the formation of biotransformation products of micropollutants both qualitatively and quantitatively during activated sludge treatment. The transformation products were detected by high-resolution mass spectrometry and were shown to be also present in the effluent water of a municipal wastewater treatment plant.
Matrix effect in detection
In quantitative analysis, the matrix has an influence on the ionization process. The matrix effect may differ between ionization techniques, ionization modes, or the equipment used. When analyzing wastewater treatment plant effluent samples, the matrix causes variations in the results depending on the source. Garcia-Ac et al. (2011) observed strong matrix effects with APCI and APPI when analyzing pharmaceuticals. However, opposite results have also been reported (Zuehlke et al. 2004; Theron et al. 2007). In addition, it has been concluded that the matrix effect is dependent on the LC-MS interface, as the ionization mechanism is different, and this may have an effect on the formation of the desired ions in the presence of matrix compounds.
Earlier studies have shown that matrix effects may differ between various ionization techniques, modes (positive or negative), or instruments (Antignac et al. 2005). The matrix of wastewater treatment plant effluent gives varying results, depending on the source (Garcia-Ac et al. 2011). In addition, it has been shown (Robb et al. 2000) that APCI and APPI can be less sensitive to matrix effects than ESI, but according to Garcia-Ac et al. (2011), strong matrix effects have been observed with both methods.
The source of the matrix effect is the presence of endogenous substances, i.e., co-extracted organic or inorganic molecules, in the sample. Therefore, it has been suggested that the solution might be a more selective analyte extraction (Benijts et al. 2004; Van de Steene et al. 2006). The matrix effects on the ionization process can be compensated for by standard additions when analyzing environmental samples. This method is a relatively fast and efficient way to correct signal distortion effects. However, the internal standard does not bind to the sample matrix in a similar way as the analyte which may lead to incorrect results. The extent of error depends on the analyte and the matrix. If the internal standard addition method is performed correctly with sufficient mixing and equilibration, relatively reliable results can be gained.
Ferguson et al. (2001) reported a highly selective method for the determination of steroid estrogens that uses a selective immunosorbent in the sample preparation and allows the removal of the interfering sample matrix present in wastewater. Immunoextraction removes much of the isobaric noise, increases the signal-to-noise ratios of the analytes, and gives lower detection limits. Coupled to HPLC followed by ESI-MS, it has been shown to be a sensitive method for the analysis of steroid estrogens in aqueous matrices (Ferguson et al. 2001).
Signal suppression or enhancement effects have been widely reported in atmospheric pressure ionization (API) when analyzing samples with complex matrices (Viglino et al. 2008). Matrix effects can be evaluated according to equation 1, where RWs is the analyte peak area in the water sample spiked with target compounds, RWns is the peak area in the original water sample, and DIs is the peak area of the deionized water spiked with the same amount of analyte (Garcia-Ac et al. 2009).
(1)
When analyzing samples with complex matrices, co-eluting compounds can result in signal enhancement or suppression. Methods for the determination of analytes in environmental matrices have to be suitable for detecting parent compounds, as well as their metabolites and transformation products. The chosen method of analysis should be able to diminish matrix effects (Van de Steene et al. 2006). Often, LC-MS/MS with triple quadrupoles or time-of-flight is considered the best choice (Petrovic et al. 2005). Ion trap instruments are more suitable for screening purposes.
Large numbers of compounds are often present in environmental samples such as river water and wastewater. Co-eluting compounds originating from the matrix may cause signal enhancement or suppression. Matrix compounds entering the ion source at the same time with analytes may decrease the ionization efficiency (Taylor 2005). The best way to study matrix effects is to use isotopically labeled internal standards (Benijts et al. 2004; Petrovic et al. 2005; Taylor 2005) or structural analogues that are not present in the sample.
Van De Steene et al. (2006) reported that a lower flow rate injected into the LC-MS system has a beneficial effect on matrix suppression. Especially in the ESI mode, too many compounds are eluting and ionized at the same time, and the matrix effect can affect the reproducibility and accuracy of the method. At a lower flow, smaller droplets form and the total surface area of the droplets increases. The competition between analyte and matrix components at the droplet surface is reduced, and more of the analyte can be ionized (Kloepfer et al. 2005).
Compared to the common flow rate (1 mL/min), a lower flow rate (200 µL/min) gives practically no matrix effect. However, a standard addition is required for the quantitative analysis to overcome the problem of a changing matrix. The best result can be achieved using structural analogues as internal standards (Van De Steene et al. 2006). In this way, a method such as the SPE–LC–MS/MS gives a minimal matrix effect without significant loss of analytes. Depending on the type of ionization used in the LC-MS/MS analysis, the matrix can have an effect on the quantification. For example, ESI is more likely to produce interference compared to APCI (Dams et al. 2003).
SUMMARY STATEMENTS
- There are multiple sample preparation methods suitable for the analyses of organic compounds. For example, SPME requires a small volume, and SDME needs practically no organic solvent. These methods are fast and can be easily automated. In the new TF-SPME method, a C18 extraction phase is deposited on a flat, thin, stainless steel surface. The immobilized particles have a larger surface-area-to-volume-ratio and offer a faster analysis rate and an improved sensitivity.
- On-line extraction methods have been proposed as well. On-line SPE has been reported as one of the most promising techniques for the rapid extraction and preconcentration of most pharmaceuticals, even though the analysis of groups of compounds with varying hydrophobicities is challenging. In addition, a fast TF-SPME analysis can be performed using a robotic autosampler that enables 96 parallel analyte extractions.
- Currently, analysis methods based on LC-MS/MS are commonly used. Because large proportions of pollutants in the aquatic environment are polar, no derivatization is required. However, in case of slightly polar and non-polar compounds analysis methods based on GC cannot be omitted. For example, the trend towards use of two-dimensional GC is recognizable. Analysis with GC may require the derivatization of analytes to improve their volatility or to suppress competing compounds present in the sample.
- The most common ionization methods are APCI, ESI, and APPI. The APPI technique can ionize compounds with various polarities, regardless of matrix compounds. It has been successfully applied in the analyses of environmental and pharmaceutical samples. It has been observed that peaks gained by ESI were higher and their signal-to-noise ratios were better than those with APPI and APCI.
- The compounds with high molecular mass, e.g. humic substances commonly found in environmental aquatic matrices especially in Nordic countries, are known to affect the ionization of polar analytes with lower molecular weight. In order to reach reliable analysis results, the matrix effects must be minimized. Matrix effects can be evaluated by using isotopically labeled internal standards or structural analogues not present in the sample. In addition, matrix effects can be suppressed using a lower flow rate in the system of analysis.
- Often, LC-MS/MS with triple quadrupoles or time-of-flight is considered the best choice to diminish matrix effects. Ion trap instruments are more suitable for screening purposes. Matrix effects may vary between different instruments, ionization techniques, or modes (positive or negative). APCI and APPI can be less sensitive to matrix effects than ESI, but strong matrix effects may occur with both methods.
ACKNOWLEDGMENTS
Financial support from the Maa- ja vesitekniikan tuki ry. is gratefully acknowl-edged. Emeritus Prof. Matti Nurmia’s language consultation is also appreciated.
REFERENCES CITED
Adrian, M., Jeandet, P., Breuil, A. C., Levite, D., Debord, S., and Bessis, R. (2000). “Assay of resveratrol and derivative stilbenes in wines by direct injection high performance liquid chromatography,” Am. J. Enol. Viticult. 51(1), 37‑41.
Aerni, H. R., Kobler, B., Rutishauser, B. V., Wettstein, F. E., Fischer, R., Giger, W., Hungerbühler, A., Marazuela, M. D., Peter, A., Schönenberger, R., Vögeli, A. C., Suter, M. J. F., and Eggen, R. I. L. (2004). “Combined biological and chemical assessment of estrogenic activities in wastewater treatment plant effluent,” Anal. Bioanal. Chem. 378(3), 688-696.
Ahkola, H., Herve, S., and Knuutinen, J. (2013). “Overview of passive Chemcatcher sampling with SPE pretreatment suitable for the analysis of NPEOs and NPs,” Environ. Sci. Pollut. Res. 20(3), 1207‑1218.
Almeida, C., and Nogueira, J. M. F. (2006). “Determination of steroid sex hormones in water and urine matrices by stir bar sorptive extraction and liquid chromatography with diode array detection,” J. Pharm. Biomed. Anal. 41(4), 1303-1311.
Alvarez, D. A., Petty, J. D., Huckins, J. N., Jones-Lepp, T. L., Getting, D. T., Goddard, J. P., and Manahan, S. E. (2004). “Development of a passive, in situ, integrative sampler for hydrophilic organic contaminants in aquatic environments,” Environ. Toxicol. Chem. 23(7), 1640‑1648.
Alvarez, D. A., Stackelberg, P. E., Petty, J. D., Huckins, J. N., Furlong, E. T., Zaugg, S. D., and Meyer, M. T. (2005). “Comparison of a novel passive sampler to standard water-column sampling for organic contaminants associated with wastewater effluents entering a New Jersey stream,” Chemosphere 61(5), 610-622.
Andrási, N., Helenkár, A., Vasanits-Zsigrai, A., Záray, G., and Molnár-Perl, I. (2011a). “Derivatization and fragmentation pattern analysis of natural and synthetic steroids, as their trimethylsilyl (oxime) ether derivatives by gas chromatography mass spectrometry: Analysis of dissolved steroids in wastewater samples,” J. Chromatogr. A 1218(14), 1878-1890.
Andrási, N., Helenkár, A., Vasanits-Zsigrai, A., Záray, Gy., and Molnár-Perl, I. (2011b). “The role of the acquisition methods in the analysis of natural and synthetic steroids and cholic acids by gas chromatography–mass spectrometry,” J. Chromatogr. A 1218(45), 8264-8272.
Antignac, J. P., de Wasch, K., Monteau, F., De Brabander, H., Andre, F., and Le Bizec, B. (2005). “The ion suppression phenomenon in liquid chromatography-mass spectrometry and its consequences in the field of residue,” Anal. Chim. Acta 529(1‑2), 129‑136.
Antoniou, C. V., Koukouraki, E. E., and Diamadopoulos, E. (2006). “Determination of chlorinated volatile organic compounds in water and municipal wastewater using headspace–solid phase microextraction–gas chromatography,” J. Chromatogr. A 1132(1-2), 310-314.
Arthur, C. L., and Pawliszyn, J. (1990). “Solid phase microextraction with thermal desorption using fused silica optical fibers,” Anal. Chem. 62(19), 2145‑2148.
Asi, M. R., Hussain, A., and Muhmood, S. T. (2008). “Solid phase extraction of pesticide residues in water samples: DDT and its metabolites,” Int. J. Environ. Res. 2(1), 43‑48.
Aznar, R., Sánchez-Brunete, C., Albero, B., Rodríguez, J. A., and Tadeo, J. L. (2014). “Occurrence and analysis of selected pharmaceutical compounds in soil from Spanish agricultural fields,” Environ. Sci. Pollut. Res. 21(6), 4772‑4782.
Balakrishnan, V. K., Terry, K. A., and Toito, J. (2006). “Determination of sulfonamide antibiotics in wastewater: A comparison of solid phase microextraction and solid phase extraction methods,” J. Chromatogr. A 1131(1‑2), 1‑10.
Baltussen, E., David, F., Sandra, P., Janssen, H.-G., and Cramers, C. (1998). “Capillary GC determination of amines in aqueous samples using sorptive preconcentration on polydimethylsiloxane and polyacrylate phases,” J. High Resolut. Chromatogr. 21(12), 645‑648.
Baronti, C., Curini, R., D´Ascenzo, G., Di Corcia, A., Gentili, A., and Samperi, R. (2000). “Monitoring natural and synthetic estrogens at activated sludge sewage treatment plants and in a receiving river water,” Environ. Sci. Technol. 34(24), 5059‑5066.
Bateman, K. P., Locke, S. J., and Volmer, D. A. (1997). “Characterization of isomeric sulfonamides using capillary zone electrophoresis coupled with nano-electrospray quasi-MS/MS/MS,” J. Mass Spectrom. 32(3), 297-304.
Beck, I.-C., Bruhn, R., and Gandrass, J. 2006. “Analysis of estrogenic activity in coastal surface waters of the Baltic Sea using the yeast estrogen screen,” Chemosphere 63(11), 1870-1878.
Benijts, T., Dams, R., Lambert, W., and De Leenheer, A. (2004). “Countering matrix effects in environmental liquid chromatography-electrospray ionization tandem mass spectrometry water analysis for endocrine disrupting chemicals,” J. Chromatogr. A 1029(1‑2), 153-159.
Berger, U., and Haukås, M. (2005). “Validation of a screening method based on liquid chromatography coupled to high-resolution mass spectrometry for analysis of perfluoroalkylated substances in biota,” J. Chromatogr. A 1081(2), 210-217.
Berggren, C., Bayoudh, S., Sherrington, D., and Ensing, K. (2000). “Use of molecularly imprinted solid-phase extraction for the selective clean-up of clenbuterol from calf urine,” J. Chromatogr. A 889(1‑2), 105‑110.
Bianchi, F., Dugheri, S., Musci, M., Bonacchi, A., Salvadori, E., Arcangeli, G., Cupelli, V., Lanciotti, M., Masieri, L., Serni, S., Carini, M., Careri, M., and Mangia, A. (2011). “Fully automated solid-phase microextraction–fast gas chromatography–mass spectrometry method using a new ionic liquid column for high-throughput analysis of sarcosine and N-ethylglycine in human urine and urinary sediments,” Anal. Chim. Acta 707(1-2), 197‑203.
Björkblom, C., Salste, L., Katsiadaki, I., Wiklund, T., and Kronberg, L. (2008). “Detection of estrogenic activity in municipal wastewater effluent using primary cell cultures from three-spined stickleback and chemical analysis,” Chemosphere 73(7), 1064-1070.
Bogusz, M. J., Krüger, K. D., and Maier, R. D. (2000). “Analysis of underivatized amphetamines and related phenethylamines with high-performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry,” J. Anal. Toxicol. 24(2), 77-84.
Buszewski, B., and Ligor, T. (2002). “Single-drop extraction versus solid-phase microextraction for the analysis of VOCs in water,” LC∙GC Eur. 15(2), 92-96.
Cahill, J. D., Furlong, E. T., Burkhardt, M. R., Kolpin, D. L., and Anderson, G. (2004). “Determination of pharmaceutical compounds in surface- and ground-water samples by solid-phase extraction and high-performance liquid chromatography-electrospray ionization mass spectrometry,” J. Chromatogr. A 1041(1-2), 171-180.
Calderón-Preciado, D., Jiménez-Cartagena, C., Matamoros, V., and Bayona, J. M. (2011). “Screening of 47 organic microcontaminants in agricultural irrigation waters and their soil loading,” Water Res. 45(1), 221‑231.
Camilleri, J., Morin, N., Miège, C., Coquery, M., and Cren-Olivé, C. (2012). “Determination of the uptake and release rates of multifamilies of endocrine disruptor compounds on the polar C18 Chemcatcher. Three potential performance reference compounds to monitor polar pollutants in surface water by integrative sampling,” J. Chromatogr. A 1237, 37-45.
Campbell, C. G., Borglin, S. E., Green, F. B., Grayson, A., Wozei, E., and Stringfellow, W. T. (2006). “Biologically directed environmental monitoring, fate, and transport of estrogenic endocrine disrupting compounds in water: A review,” Chemosphere 65(8), 1265-1280.
Cantwell, M. G., Wilson, B. A., Zhu, J., Wallace, G. T., King, J. W., Olsen, C. R., Burgess, R. M., and Smith, J. P. (2010). “Temporal trends of triclosan contamination in dated sediment cores from four urbanized estuaries: Evidence of preservation and accumulation,” Chemosphere, 78(4), 347-352.
Carballa, M., Omil, F., Lema, J. M., Llompart, M., García-Jares, C., Rodríguez, I., Gómez, M., and Ternes, T. (2004). “Behavior of pharmaceuticals, cosmetics and hormones in a sewage treatment plant,” Water Res. 38(12), 2918-2926.
Cargouët, M., Perdiz, D., Mouatassim-Souali, A., Tamisier-Karolak, S., and Levi, Y. (2004). “Assessment of river contamination by estrogenic compounds in Paris area (France),” Sci. Total Environ. 324(1-3), 55-66.
Carignan, G., and Carrier, K. (1991). “Quantitation and confirmation of sulfamethazine residues in swine muscle and liver by LC and GC/MS,” J. Assoc. Off. Anal. Chem. 74(3), 479‑482.
Caro, E., Marcé, R. M., Cormack, P. A.G., Sherrington, D. C., and Borrull, F. (2003). “On-line solid-phase extraction with molecularly imprinted polymers to selectively extract substituted 4-chlorophenols and 4-nitrophenol from water,” J. Chromatogr. A 995(1‑2), 233-238.
Castiglioni, S., Bagnati, R., Calamari, D., Fanelli, R., and Zuccato, E. (2005). “A multi-residue analytical method using solid-phase extraction and high-pressure liquid chromatography tandem mass spectrometry to measure pharmaceuticals of different therapeutic classes in urban wastewaters,” J. Chromatogr. A 1092(2), 206‑215.
Castiglioni, S., Zuccato, E., Chiabrando, C., Fanelli, R., and Bagnati, R. (2008). “Mass spectrometric analysis of illicit drugs in wastewater and surface water,” Mass Spectrom. Rev. 27(4), 378‑394.
Cervera, M. I., Beltran, J., Lopez, F. J., and Hernández, F. (2011). “Determination of volatile organic compounds in water by head space-solid-phase microextraction gas chromatography coupled to tandem mass spectrometry with triple quadrupole analyzer,” Anal. Chim. Acta 704(1-2), 87-97.
Cha, W., Fox, P. P., and Nalinakumari, P. (2006). “High-performance liquid chromatography with fluorescence detection for aqueous analysis of nanogram-level N-nitrosodimethylamine,” Anal. Chim. Acta 566(1), 109‑116.
Champagne, P., and Li, C. (2009). “Enzymatic hydrolysis of cellulosic municipal wastewater treatment process residuals as feedstocks for the recovery of simple sugars,” Biores. Technol. 100(23), 5700-5706.
Cheng, C.-Y., Wang, Y.-C., and Ding, W.-H. (2011). “Determination of triclosan in aqueous samples using solid-phase extraction followed by on-line derivatization gas chromatography–mass spectrometry,” Anal. Sci. 27(2), 197‑202.
Cherta, L., Beltran, J., Portolés, T., and Hernández, F. (2012). “Multiclass determination of 66 organic micropollutants in environmental water samples by fast gas chromatography–mass spectrometry,” Anal. Bioanal. Chem. 402(7), 2301-2314.
Chia, K.-J., and Huang, S.-D. (2005). “Simultaneous derivatization and extraction of amphetamine-like drugs in urine with headspace solid-phase microextraction followed by gas chromatography–mass spectrometry,” Anal. Chim. Acta 539(1‑2), 49‑54.
Chu, Q., O’Dwyer, M., and Zeece, M. G. (1998). “Direct analysis of resveratrol in wine by micellar electrokinetic capillary electrophoresis,” J. Agric. Food Chem. 46(2), 509‑513.
Class, K. E., Hohaus, E., and Monien, H. (1986). “Liquid column-chromatographic separation and determination of long-chain primary n-alkylamines (n-C10H21NH2 to n-C22H45NH2) after their fluorescence derivatization with salicylaldehyde diphenylboron chelate,” Fresenius Z. Anal. Chem. 325(1), 15‑19.
Clouzot, L., Marrot, B., Doumenq, P., and Roche, N. (2008). “17α-Ethinylestradiol: An endocrine disrupter of great concern. Analytical methods and removal processes applied to water purification. A review,” Environ. Prog. 27(3), 383‑396.
Cudjoe, E., Vuckovic, D., Hein, D., and Pawliszyn, J. (2009). “Investigation of the effect of the extraction phase geometry on the performance of automated solid‑phase microextraction,” Anal. Chem. 81(11), 4226-4232.
Dams, R., Huestis, M. A., Lambert, W. E., and Murphy, C. M. (2003). “Matrix effect in bio-analysis of illicit drugs with LC-MS/MS: Influence of ionization type, sample preparation, and biofluid,” J. Am. Soc. Mass Spectrom. 14(11), 1290-1294.
Das, D., Gupta, U., and Das, A. K. (2012). “Recent developments in solid phase extraction in elemental speciation of environmental samples with special reference to aqueous solutions,” Trends Anal. Chem. 38, 163‑171.
Delmonte, P., Fardin Kia, A.-R., Kramer, J. K. G., Mossoba, M. M., Sidisky, L., and Rader, J. I. (2011). “Separation characteristics of fatty acid methyl esters using SLB‑IL111, a new ionic liquid coated capillary gas chromatographic column,” J. Chromatogr. A 1218(3), 545‑554.
Deng, A., Himmelsbach, M., Zhu, Q.-Z., Frey, S., Sengl, M., Buchberger, W., Niessner, R., and Knopp, D. (2003). “Residue analysis of the pharmaceutical diclofenac in different water types using ELISA and GC−MS,” Environ. Sci. Technol. 37(15), 3422-3429.
Desbrow, C., Routledge, E. J., Brighty, G. C., Sumpter, J. P., and Waldock, M. (1998). “Identification of estrogenic chemicals in STW effluent. 1. Chemical fractionation and in vitro biological screening,” Environ. Sci. Technol. 32(11), 1549-1558.
Ding, J., Welton, T., and Armstrong, D. W. (2004). “Chiral ionic liquids as stationary phases in gas chromatography,” Anal. Chem. 76(22), 6819-6822.
Ding, W.-H., and Tsai, P.-C. (2003). “Determination of alkyltrimethylammonium chlorides in river water by gas chromatography/ion trap mass spectrometry with electron impact and chemical ionization,” Anal. Chem. 75(8), 1792-1797.
Domínguez, C., Reyes-Contreras, C., and Bayona, J. M. (2012). “Determination of benzothiazoles and benzotriazoles by using ionic liquid stationary phases in gas chromatography mass spectrometry. Application to their characterization in wastewaters,” J. Chromatogr. A 1230, 117-122.
Escher, B. I., Baumgartner, R., Lienert, J., and Fenner, K. (2009). Handbook of Environmental Chemistry: Transformation products of synthetic chemicals in the environment, A. B. A. Boxall (ed.), Springer, Berlin.
Esperanza, M., Suidan, M. T., Nishimura, F., Wang, Z.-M., Sorial, G. A., Zaffiro, A., McCauley, P., Brenner, R., and Sayles, G. (2004). “Determination of sex hormones and nonylphenol ethoxylates in the aqueous matrixes of two pilot-scale municipal wastewater treatment plants, Environ. Sci. Technol. 38(11), 3028–-3035.
Esteve‑Turrillas, F. A., Pastor, A., and de la Guardia, M. (2007). “Behaviour of semipermeable membrane devices in neutral pesticide uptake from waters,” Anal. Bioanal. Chem. 387(6), 2153‑2162.
Fent, K., Weston, A. A., and Caminada, D. (2006). “Ecotoxicology of human pharmaceuticals,” Aquat. Toxicol. 76(2), 122-159.
Ferguson, P. L., Iden, C. R., McElroy, A. E., and Brownawell, B. J. (2001). “Determination of steroid estrogens in wastewater by immunoaffinity extraction coupled with HPLC-electrospray-MS,” Anal. Chem. 73(16), 3890-3895.
Fernandez, M. P., Ikonomou, M. G., and Buchanan, I. (2007). “An assessment of estrogenic organic contaminants in Canadian wastewaters,” Sci. Total Environ. 373(1), 250‑269.
Ferrer, I., Hennion, M.-C., and Barcelò, D. (1997). “Immunosorbents coupled on-line with liquid chromatography/atmospheric pressure chemical ionization/mass spectrometry for the part per trillion level determination of pesticides in sediments and natural waters using low preconcentration volumes,” Anal. Chem. 69(22), 4508‑4514.
Ferrer, I., and Barcelò, D. (1999). “Validation of new solid-phase extraction materials for the selective enrichment of organic contaminants from environmental samples,” Trends Anal. Chem. 18(3), 180‑192.
Fiorentino, A., Gentili, A., Isidori, M., Monaco, P., Nardelli, A., Parrella, A., and Temussi, F. (2003). “Environmental effects caused by olive mill wastewaters: Toxicity comparison of low-molecular-weight phenol components,” J. Agric. Food Chem. 51(4), 1005‑1009.
Fischer, K., Fries, E., Körner, W., Schmalz, C., and Zwiener, C. (2012). “New developments in the trace analysis of organic water pollutants,” Appl. Microbiol. Biotechnol. 94(1), 11–28.
Furuichi, T., Kannan, K., Giesy, J. P., and Masunaga, S. (2004). “Contribution of known endocrine disrupting substances to the estrogenic activity in Tama River water samples from Japan using instrumental analysis and in vitro reporter gene assay,” Water Res. 38(20), 4491-4501.
Gajdošová, D., Novotná, K., Prošek, P., and Havel, J. (2003). “Separation and characterization of humic acids from Antarctica by capillary electrophoresis and matrix-assisted laser desorption ionization time-of-flight mass spectrometry: Inclusion complexes of humic acids with cyclodextrins,” J. Chromatogr. A 1014(1‑2), 117-127.
Garcia-Ac, A., Segura, P. A., Viglino, L., Fürtös, A., Gagnon C., Prévost, M. and Sauvé, S. (2009). “On-line solid-phase extraction of large-volume injections coupled to liquid chromatography-tandem mass spectrometry for the quantitation and confirmation of 14 selected trace organic contaminants in drinking and surface water,” J. Chromatogr. A. 1216(48), 8518-8527.
Garcia-Ac, A., Segura, P.A., Viglino, L., Gagnon C., and Sauvé, S. (2011). “Comparison of APPI, APCI and ESI for the LC-MS/MS analysis of bezafibrate, cyclophosphamide, enalapril, methotrexate and orlistat in municipal wastewater,” J. Mass. Spectrom. 46(4), 383-390.
García-Galán, M. J., Díaz-Cruz, M. S., and Barceló, D. (2010). “Determination of 19 sulfonamides in environmental water samples by automated on-line solid-phase extraction-liquid chromatography–tandem mass spectrometry (SPE‑LC–MS/MS),” Talanta 81(1-2), 355-366.
Gentili, A., Perret, D., Marchese, S., Mastropasqua, R., Curini, R., and Di Corcia, A. (2002). “Analysis of free estrogens and their conjugates in sewage and river waters by solid-phase extraction then liquid chromatography-electrospray-tandem mass spectrometry,” Chromatographia 56(1), 25‑32.
Giger, W., Schaffner, C., and Kohler, H.-P.E. (2006). “Benzotriazole and tolyltriazole as aquatic contaminants. 1. Input and occurrence in rivers and lakes,” Environ. Sci. Technol. 40(23), 7186-7192.
Giger, W. (2009). “Hydrophilic and amphiphilic water pollutants: Using advanced analytical methods for classic and emerging contaminants,” Anal. Bioanal. Chem. 393(1), 37-44.
Golet, E. M., Alder, A. C., Hartmann, A., Ternes, T. A., and Giger, W. (2001). “Trace determination of fluoroquinolone antibacterial agents in urban wastewater by solid‑phase extraction and liquid chromatography with fluorescence detection,” Anal. Chem. 73(15), 3632‑3638.
Górecki, T., and Namieśnik, J. (2002). “Passive sampling,” Trends Anal. Chem. 21(4), 276‑291.
Grebel, J. E., Young, C. C., and Suffet, I. H. (2006). “Solid-phase microextraction of N-nitrosamines” J. Chromatogr. A 1117(1), 11-18.
Greenwood, R., Mills, G. A., Vrana, B., Allan, I., Aguilar-Martínez, R., and Morrison G. (2007). Passive Sampling Techniques in Environmental Monitoring, R. Greenwood, G. A. Mills, B. Vrana, eds., Elsevier, Amsterdam.
Gros, M., Petrović, M., and Barceló, D. (2007). “Wastewater treatment plants as a pathway for aquatic contamination by pharmaceuticals in the Ebro river basin (Northeast Spain),” Environ. Toxicol. Chem. 26(8), 1553‑1562.
Guimarães, A. D., Carvalho, J. J., GonÇalves¸ C., and Alpendurada, M. d. F. (2008). “Simultaneous analysis of 23 priority volatile compounds in water by solid-phase microextraction–gas chromatography–mass spectrometry and estimation of the method’s uncertainty,” Int. J. Environ. Anal. Chem. 88(3), 151-164.
Guo, Z., Zhang, Q., Zou, H., Guo, B., and Ni, J. (2002). “A method for analysis of low-mass molecules by MALDI-TOF mass spectrometry,” Anal. Chem. 74(7), 1637‑1641.
Gut, I. G. (2004). “DNA analysis by MALDI-TOF mass spectrometry,” Hum. Mutat. 23(5), 437-441.
Göbel, A., McArdell, C. S., Joss, A., Siegrist, H., and Giger, W. (2007). “Fate of sulfonamides, macrolides, and trimethoprim in different wastewater treatment technologies,” Sci. Total Environ. 372(2-3), 361-371.
Halling-Sørensen, B., Nielsen, S. N., Lanzky, P. F., Ingerslev, F., Holten Lützhøft, H. C., and Jørgensen, S. E. (1998). “Occurrence, fate and effects of pharmaceutical substances in the environment‑A review,” Chemosphere 36(2), 357‑393.
Hanold, K. A., Fischer, S. M., Cormia, P. H., Miller, C. E., and Syage, J. A. (2004). “Atmospheric pressure photoionization. 1. General properties for LC/MS,” Anal. Chem. 76(10), 2842-2851.
Hartig, C., Storm, T., and Jekel, M. (1999). “Detection and identification of sulphonamide drugs in municipal waste water by liquid chromatography coupled with electrospray ionisation tandem mass spectrometry,” J. Chromatogr. A 854(1-2), 163-173.
Hernández, F., Sancho, J. V., Pozo, O., Lara A., and Pitarch, E. (2001). “Rapid direct determination of pesticides and metabolites in environmental water samples at sub‑μg/l level by on-line solid-phase extraction-liquid chromatography–electrospray tandem mass spectrometry,” J. Chromatogr. A 939(1‑2), 1-11.
Horie, M., Saito, K., Hoshino, Y., Nose, N., Hamada, N., and Nakazawa, H. (1990). “Identification and determination of sulphamethazine and N4-acetylsulphamethazine in meat by high-performance liquid chromatography with photodiode-array detection,” J. Chromatogr. A 502, 371‑378.
Hu, L., Xu, S., Pan, C., Yuan, C., Zou, H., and Jiang, G. (2005). “Matrix-assisted laser desorption/ ionization time-of-flight mass spectrometry with a matrix of carbon nanotubes for the analysis of low-mass compounds in environmental samples,” Environ. Sci. Technol. 39(21), 8442-8447.
Huang, C. H., and Sedlak, D. L. (2001). “Analysis of estrogenic hormones in municipal wastewater effluent and surface water using enzyme-linked immunosorbent assay and gas chromatography/tandem mass spectrometry,” Environ. Toxicol. Chem. 20(1), 133‑139.
Huber, M. M., Ternes, T. A., and von Gunten, U. (2004). “Removal of estrogenic activity and formation of oxidation products during ozonation of 17α-ethinylestradiol,” Environ. Sci. Technol. 38(19), 5177-5186.
Huckins, J. N., Tubergen, M. W., and Manuweera, G. K. (1990). “Semipermeable membrane devices containing model lipid: A new approach to monitoring the bioavailability of lipophilic contaminants and estimating their bioconcentration potential,” Chemosphere 20(5), 533‑552.
Huset, C. A., Chiaia, A. C., Barofsky, D. F., Jonkers, N., Kohler, H.-P. E., Ort, C., Giger, W., and Field, J. A. (2008). “Occurrence and mass flows of fluorochemicals in the Glatt valley watershed, Switzerland,” Environ. Sci. Technol. 42(17), 6369-6377.
Isobe, T., Shiraishi, H., Yasuda, M., Shinoda, A., Suzuki, H., and Morita, M. (2003). “Determination of estrogens and their conjugates in water using solid-phase extraction followed by liquid chromatography–tandem mass spectrometry,” J. Chromatogr. A984(2), 195-202.
de Jager, L. S., and Andrews, A. R. J. (2000). “Development of a rapid screening technique for organochlorine pesticides using solvent microextraction (SME) and fast gas chromatography (GC),” Analyst125(11), 1943-1948.
Jiang, M., Zhang, J., Mei, S., Shi, Y., Zou, L., Zhu, Y., Dai, K., and Lu, B. (2006). “Direct enrichment and high performance liquid chromatography analysis of ultra-trace Bisphenol A in water samples with narrowly dispersible Bisphenol A imprinted polymeric microspheres column,” J. Chromatogr. A 1110(1‑2), 27‑34.
Johnson, A. C., Belfroid, A., and Di Corcia, A. (2000). “Estimating steroid oestrogen inputs into activated sludge treatment works and observations on their removal from the effluent,” Sci. Total Environ. 256(2-3), 163-173.
Johnson, A. C., and Sumpter, J. P. (2001). “Removal of endocrine-disrupting chemicals in activated sludge treatment works,” Environ. Sci. Technol. 35(24), 4697‑4703.
Johnson, A. C., and Williams, R. J. (2004). “A model to estimate influent and effluent concentrations of estradiol, estrone, and ethinylestradiol at sewage treatment works,” Environ. Sci. Technol. 38(13), 3649-3658.
Jones-Lepp, T. L., Alvarez, D. A., Petty, J. D., and Huckins, J. N. (2004). “Polar organic chemical integrative sampling and liquid chromatography–electrospray/ion-trap mass spectrometry for assessing selected prescription and illicit drugs in treated sewage effluents,” Arch. Environ. Contam. Toxicol. 47(4), 427-439.
Jover, E., Matamoros, V., and Bayona, J. M. (2009). “Characterization of benzothiazoles, benzotriazoles and benzosulfonamides in aqueous matrixes by solid-phase extraction followed by comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry,” J. Chromatogr. A1216(18), 4013-4019.
Juraske, R., Antón, A., Castells, F., and Huijbregts, M. A. J. (2007). “PestScreen: A screening approach for scoring and ranking pesticides by their environmental and toxicological concern,” Environ. Int. 33(7), 886-893.
Karlsson, K., Sipiä, V., Krause, E., Meriluoto, J., and Pflugmacher, S. 2003). “Mass spectrometric detection and quantification of nodularin-R in flounder livers,” Environ. Toxicol. 18(5), 284-288.
Keith, L. H., Jones-Lepp, T. L., and Needham, L. L. (2000). Analysis of Environmental Endocrine Disruptors, American Chemical Society, Washington, DC.
Kelly, M. T., and Larroque, M. (1999). “Trace determination of diethylphthalate in aqueous media by solid-phase microextraction–liquid chromatography,” J. Chromatogr. A 841(2), 177-185.
Kern, S., Baumgartner, R., Helbling, D. E., Hollender, J., Singer, H., Loos, M. J., Schwarzenbach, R. P., and Fenner, K. (2010). “A tiered procedure for assessing the formation of biotransformation products of pharmaceuticals and biocides during activated sludge treatment,” J. Environ. Monit. 12(11), 2100-2111.
Kim, D., Han, J., and Choi, Y. (2013). “On-line solid-phase microextraction of triclosan, bisphenol A, chlorophenols, and selected pharmaceuticals in environmental water samples by high-performance liquid chromatography–ultraviolet detection,” Anal. Bioanal. Chem. 405(1), 377-387.
Kingston, J. K., Greenwood, R., Mills, G. A., Morrison, G. M., and Björklund Persson, L. (2000). “Development of a novel passive sampling system for the timeaveraged measurement of a range of organic pollutants in aquatic environments,” J. Environ. Monit. 2(5), 487‑495.
Kirkbride, K. P., Klass, G., and Pigou, P. E. (1998). “Application of solid‑phase microextraction to the recovery of organic explosives,” J. Forensic Sci. 43(1), 76‑81.
Kloepfer, A., Quintana, J. B., and Reemtsma, T. (2005). “Operational options to reduce matrix effects in liquid chromatography–electrospray ionisation-mass spectrometry analysis of aqueous environmental samples,” J. Chromatogr. A 1067(1-2), 153‑160.
Knapp, D. R. (1979). Handbook of Analytical Derivatization Reactions, John Wiley and Sons, New York.
Koeber, R., Fleischer, C., Lanza, F., Boos, K.-S., Sellergren, B., and Barceló, D. (2001). “Evaluation of a multidimensional solid-phase extraction platform for highly selective on-line cleanup and high-throughput LC−MS analysis of triazines in river water samples using molecularly imprinted polymers,” Anal. Chem. 73(11), 2437‑2444.
Kolb, M., Schieder, D., Faulstich, M., and Sieber, V. (2013). “Analysis of lignocellulose derived phenolic monomers by headspace solid-phase microextraction and gas chromatography,” J. Chromatogr. A 1307, 144‑157.
Kolpin, D. W., Furlong, E. T., Meyer, M. T., Thurman, E. M., Zaugg, S. D., Barber, L. B., and Buxton, H. T. (2001). “Pharmaceuticals, hormones, and other organic wastewater contaminants in U. S. streams, 1999−2000: A national reconnaissance,” Environ. Sci. Technol. 36(6), 1202-1211.
Kostamo, A., Holmblom, B., and Kukkonen, J. V. K. (2004). “Fate of wood extractives in wastewater treatment plants at kraft pulp mills and mechanical pulp mills,” Water Res. 38(4), 972‑982.
Kotowska, U., Żalikowski, M., and Isidorov, V. A. (2012). “HS-SPME/GC–MS analysis of volatile and semi-volatile organic compounds emitted from municipal sewage sludge,” Environ. Monit. Assess. 184(5), 2893-2907.
Kraemer, T., and Paul, L. D. (2007). “Bioanalytical procedures for determination of drugs of abuse in blood,” Anal. Bioanal. Chem. 388(7), 1415-1435.
Krauss, M., and Hollender, J. (2008). “Analysis of nitrosamines in wastewater: exploring the trace level quantification capabilities of a hybrid linear ion trap/orbitrap mass spectrometer,” Anal. Chem. 80(3), 834-842.
Krauss, M., Singer, H., and Hollender, J. (2010). “LC–high resolution MS in environmental analysis: From target screening to the identification of unknowns,” Anal. Bioanal. Chem. 397(3), 943-951.
Kusch, P., Knupp, G., Hergarten, M., Kozupa, M., and Majchrzak, M. (2006). “Solid-phase extraction-gas chromatography and solid-phase extraction-gas chromatography–mass spectrometry determination of corrosion inhibiting long-chain primary alkyl amines in chemical treatment of boiler water in water-steam systems of power plants,” J. Chromatogr. A 1113(1-2), 198‑205.
Kümmerer, K. (2004). Pharmaceuticals in the Environment, Springer-Verlag, New York.
Laganà, A., Bacaloni, A., Fago, G., and Marino, A. (2000). “Trace analysis of estrogenic chemicals in sewage effluent using liquid chromatography combined with tandem mass spectrometry,” Rapid Commun. Mass Spectrom. 14(6), 401-407.
Laganà, A., Bacaloni, A., De Leva, I., Faberi, A., Fago, G., and Marino, A. (2004). “Analytical methodologies for determining the occurrence of endocrine disrupting chemicals in sewage treatment plants and natural waters,” Anal. Chim. Acta 501(1), 79-88.
Lai, E. P. C., and Wu, S. G. (2003). “Molecularly imprinted solid phase extraction for rapid screening of cephalexin in human plasma and serum,” Anal. Chim. Acta 481(2), 165‑174.
Layton, A. C., Gregory, B. W., Seward, J. R., Schultz, T. W., and Sayler, G. S. (2000). “Mineralization of steroidal hormones by biosolids in wastewater treatment systems in Tennessee U.S.A.,” Environ. Sci. Technol. 34(18), 3925-3931.
Lee, H.-B., Peart, P. E., and Svoboda, M. L. (2005). “Determination of endocrine-disrupting phenols, acidic pharmaceuticals, and personal-care products in sewage by solid-phase extraction and gas chromatography–mass spectrometry,” J. Chromatogr. A 1094(1-2), 122‑129.
Liu, H., and Dasgupta, P. K. (1996). “Analytical chemistry in a drop. Solvent extraction in a microdrop,” Anal. Chem. 68(11), 1817-1821.
Liu, X. L., Wu, F., and Deng, N. S. (2003). “Photodegradation of 17α-ethynylestradiol in aqueous solution exposed to a high-pressure mercury lamp (250 W),” Environ. Pollut. 126(3), 393-398.
Llop, A., Pocurull, E., and Borrull, F. (2010). “Automated determination of aliphatic primary amines in wastewater by simultaneous derivatization and headspace solid-phase microextraction followed by gas chromatography–tandem mass spectrometry,” J. Chromatogr. A 1217(4), 575-581.
López-Blanco, M. C., Blanco-Cid, S., Cancho-Grande, B., and Simal-Gándara, J. (2003). “Application of single-drop microextraction and comparison with solid-phase microextraction and solid-phase extraction for the determination of α- and β-endosulfan in water samples by gas chromatography–electron-capture detection,” J. Chromatogr. A 984(2), 245-252.
Lord, H., and Pawliszyn, J. (2000) “Evolution of solid-phase microextraction technology,” J. Chromatogr. A 885(1‑2), 153-193.
Luks-Betlej, K., Popp, P., Janoszka, B., and Paschke, H. (2001). “Solid-phase microextraction of phthalates from water,” J. Chromatogr. A 938(1-2), 93–101.
Luque de Castro, M. D., and Priego-Capote, F. (2007). “Ultrasound-assisted preparation of liquid samples,” Talanta 72(2), 321-334.
MacLeod, S. L., McClure, E. L., and Wong, C. S. (2007). “Laboratory calibration and field deployment of the polar organic chemical integrative sampler for pharmaceuticals and personal care products in wastewater and surface water,” Environ. Toxicol. Chem. 26(12), 2517‑2529.
Marchi, I., Rudaz, S., and Veuthey. J.-L. (2009). “Atmospheric pressure photoionization for coupling liquid-chromatography to mass spectrometry: A review,” Talanta 78(1), 1‑18.
Marie, A., Fournier, F., and Tabet, J. C. (2000). “Characterization of synthetic polymers by MALDI-TOF/MS: Investigation into new methods of sample target preparation and consequence on mass spectrum fingerprint,” Anal. Chem. 72(20), 5106-5114.
Martín-Esteban, A. (2001). “Molecularly imprinted polymers: New molecular recognition materials for selective solid-phase extraction of organic compounds,” Fresenius J. Anal. Chem. 370(7), 795‑802.
Martínez-Ortega, M. V., García-Parrilla, M. C., and Troncoso, A. M. (2001). “Changes in phenolic composition of wines submitted to in vitro dissolution tests,” Food Chem. 73(1), 11‑16.
Martinović, D., Hogarth, W. T., Jones, R. E., and Sorensen, P. W. (2007). “Environmental estrogens suppress hormones, behavior, and reproductive fitness in male fathead minnows,” Environ. Toxicol. Chem. 26(2), 271-278.
Masqué, N., Marcé, R. M., Borrull, F., Cormack, P. A. G., and Sherrington, D. C. (2000). “Synthesis and evaluation of a molecularly imprinted polymer for selective on-line solid-phase extraction of 4-nitrophenol from environmental water,” Anal. Chem. 72(17), 4122‑4126.
Matusik, J. E., Sternal, R. S., Barnes, C. J., and Sphon, J. A. (1990). “Confirmation of identity by gas chromatography/tandem mass spectrometry of sulfathiazole, sulfamethazine, sulfachloropyridazine, and sulfadimethoxine from bovine or swine liver extracts after quantitation by gas chromatography/electron-capture detection,” J. Assoc. Off. Anal. Chem. 73(4), 529‑533.
McMartin, D. W., Peru, K. M., Headley, J. V., Winkler, M., and Gillies, J. A. (2002). “Evaluation of liquid chromatography–negative ion electrospray mass spectrometry for the determination of selected resin acids in river water,” J. Chromatogr. A 952(1‑2), 289-293.
McMurtrey, K. D., Minn, J., Pobanz, K., and Schultz, T. P. (1994). “Analysis of wines for resveratrol using direct injection high-pressure liquid chromatography with electrochemical detection,” J. Agric. Food Chem. 42(10), 2077-2080.
McNeill, K., and Cancilla, D. (2009). “Detection of triazole deicing additives in soil samples from airports with low, mid, and large volume aircraft deicing activities,” Bull. Environ. Contam. Toxicol. 82(3), 265‑269.
Mena, M. L., Martínez-Ruiz, P., Reviejo, A. J., and Pingarrón, J. M. (2002). “Molecularly imprinted polymers for on-line preconcentration by solid phase extraction of pirimicarb in water samples,” Anal. Chim. Acta 451(2), 297‑304.
Metcalfe, C. D., Koenig, B. G., Bennie, D. T., Servos, M., Ternes, T. A., and Hirsch, R. (2003a). “Occurrence of neutral and acidic drugs in the effluents of Canadian sewage treatment plants,” Environ. Toxicol. Chem. 22(12), 2872-2880.
Metcalfe, C. D., Miao, X.-S., Koenig, B. G., and Struger, J. (2003b). “Distribution of acidic and neutral drugs in surface waters near sewage treatment plants in the lower Great Lakes, Canada,” Environ. Toxicol. Chem. 22(12), 2881-2889.
Mitani, K., Fujioka, M., and Kataoka, H. (2005). “Fully automated analysis of estrogens in environmental waters by in-tube solid-phase microextraction coupled with liquid chromatography–tandem mass spectrometry,” J. Chromatogr. A 1081(2), 218‑224.
Munch, J. W., and Bassett, M. V. (2006). “Method development for the analysis of N‑nitrosodimethylamine and other N-nitrosamines in drinking water at low nanogram/liter concentrations using solid-phase extraction and gas chromatography with chemical ionization tandem mass spectrometry,” J. AOAC Int. 89(2), 486‑497.
Muscalu, A. M., Reiner, E. J., Liss, S. N., Chen, T., Ladwig, G., and Morse, D. (2011). “A routine accredited method for the analysis of polychlorinated biphenyls, organochlorine pesticides, chlorobenzenes and screening of other halogenated organics in soil, sediment and sludge by GCxGC-μECD,” Anal. Bioanal. Chem. 401(8), 2403-2413.
Möder, M., Popp, P., and Pawliszyn, J. (1998). “Characterization of water‑soluble components of slurries using solid‑phase microextraction coupled to liquid chromatography‑mass spectrometry,” J. Microcolumn Sep. 10(2), 225‑234.
Namieśnik, J., Zygmunt, B., and Jastrzębska, A. (2000). “Application of solid-phase microextraction for determination of organic vapours in gaseous matrices,” J. Chromatogr. A 885(1‑2), 405-418.
Ngim, K. K., Ebeler, S. E., Lew, M. E., Crosby, D. G., and Wong, J. W. (2000). “Optimized procedures for analyzing primary alkylamines in wines by pentafluorobenzaldehyde derivatization and GC−MS,” J. Agric. Food Chem. 48(8), 3311‑3316.
Niessen, W. M. A. (1998). “Analysis of antibiotics by liquid chromatography–mass spectrometry,” J. Chromatogr. A 812(1-2), 53-75.
Norberg, J., Thordarson, E., Mathiasson, L., and Jönsson, J. Å. (2000). “Microporous membrane liquid–liquid extraction coupled on-line with normal-phase liquid chromatography for the determination of cationic surfactants in river and wastewater,” J. Chromatogr. A869(1-2), 523-529.
Okuda, T., Kobayashi, Y., Nagao, R., Yamashita, N., Tanaka, H., Tanaka, S., Fujii, S., Konishi, C., and Houwa, I. (2008). “Removal efficiency of 66 pharmaceuticals during wastewater treatment process in Japan,” Water Sci. Technol. 57(1), 65-71.
Palmgrén, J. J., Töyräs, A., Mauriala, T., Mönkkönen, and J., Auriola, S. (2005). ”Quantitative determination of cholesterol, sitosterol, and sitostanol in cultured Caco-2 cells by liquid chromatography-atmospheric pressure chemical ionization mass spectrometry,” J. Chromatogr. B 821(2), 144-152.
Pan, C., Xu, S., Hu, L., Su, X., Ou, J., Zou, H., Guo, Z., Zhang, Y., and Guo, B. (2005). “Using oxidized carbon nanotubes as matrix for analysis of small molecules by MALDI-TOF MS,” J. Am. Soc. Mass Spectrom. 16(6), 883-892.
Peñalver, A., Pocurull, E., Borrull, F., and Marcé, R. M. (2000). “Determination of phthalate esters in water samples by solid-phase microextraction and gas chromatography with mass spectrometric detection,” J. Chromatogr. A 872(1-2), 191-201.
Peréz, S., Ferrer, I., Hennion, M. C., and Barceló, D. (1998). “Isolation of priority polycyclic aromatic hydrocarbons from natural sediments and sludge reference materials by an anti-fluorene immunosorbent followed by liquid chromatography and diode array detection,” Anal. Chem. 70(23), 4996‑5001.
Petrović, M., Hernando, M. D., Díaz-Cruz, M. S., and Barceló, D. (2005). “Liquid chromatography–tandem mass spectrometry for the analysis of pharmaceutical residues in environmental samples: A review,” J. Chromatogr. A 1067(1-2), 1‑14.
Piera, E., Erra, P., and Infante M. R. (1997). “Analysis of cationic surfactants by capillary electrophoresis,” J. Chromatogr. A 757(1-2), 275-280.
Planas, C., Palacios, Ó., Ventura, F., Rivera, J., and Caixach, J. (2008). “Analysis of nitrosamines in water by automated SPE and isotope dilution GC/HRMS: Occurrence in the different steps of a drinking water treatment plant, and in chlorinated samples from a reservoir and a sewage treatment plant effluent,” Talanta 76(4), 906-913.
Pojana, G., Bonfà, A., Busetti, F., Collarin, A., and Marcomini, A. (2004). “Estrogenic potential of the Venice, Italy, lagoon waters,” Environ. Toxicol. Chem. 23(8), 1874‑1880.
Psillakis, E., and Kalogerakis, N. (2001a). “Application of solvent microextraction to the analysis of nitroaromatic explosives in water samples” J. Chromatogr. A 907(1‑2), 211‑219.
Psillakis, E., and Kalogerakis, N. (2001b). “Solid-phase microextraction versus single-drop microextraction for the analysis of nitroaromatic explosives in water samples,” J. Chromatogr. A938(1‑2), 113-120.
Purcaro, G., Quinto Tranchida, P., Ragonese, C., Conte, L., Dugo, P., Dugo, G., and Mondello, L. (2010). “Evaluation of a rapid-scanning quadrupole mass spectrometer in an apolar × ionic-liquid comprehensive two-dimensional gas chromatography system,” Anal. Chem. 82(20), 8583‑8590.
Radke, M., Behrends, T., Förster, J., and Herrmann, R. (1999). “Analysis of cationic surfactants by microbore high-performance liquid chromatography-electrospray mass spectrometry,” Anal. Chem. 71(23), 5362-5366.
Reddy, S., Iden, C. R., and Brownawell, B. J. (2005). “Analysis of steroid conjugates in sewage influent and effluent by liquid chromatography-tandem mass spectrometry,” Anal. Chem. 77(21), 7032-7038.
Regueiro, J., Llompart, M., Psillakis, E., Garcia-Monteagudo, J.C., and Garcia-Jares, C. (2009). “Ultrasound-assisted emulsification–microextraction of phenolic preservatives in water,” Talanta 79(5), 1387-1397.
Reyes-Contreras, C., Domínguez, C., and Bayona, J. M. (2012). “Determination of nitrosamines and caffeine metabolites in wastewaters using gas chromatography mass spectrometry and ionic liquid stationary phases,” J. Chromatogr. A 1261, 164‑170.
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., and Berijani, S. (2006). “Determination of organic compounds in water using dispersive liquid–liquid microextraction,” J. Chromatogr. A 1116(1‑2), 1-9.
Richardson, S. D. (2004). “Environmental mass spectrometry: Emerging contaminants and current issues,” Anal. Chem. 76(12), 3337‑3364.
Robb, D. B., Covey, T. R., and Bruins, A. P. (2000). “Atmospheric pressure photoionization: An ionization method for liquid chromatography mass spectrometry,” Anal. Chem. 72(15), 3653-3659.
Roberts, P. H., and Bersuder, P. (2006). “Analysis of OSPAR priority pharmaceuticals using high-performance liquid chromatography-electrospray ionization tandem mass spectrometry,” J. Chromatogr. A1134(1-2), 143-150.
Roberts, P. H., and Thomas, K. V. (2006). “The occurrence of selected pharmaceuticals in wastewater effluent and surface waters of the lower Tyne catchment,” Sci. Total Environ. 356(1-3), 143-153.
Rodriguez-Mozaz, S., Lopez de Alda, M. J., and Barceló, D. (2007). “Advantages and limitations of on-line solid phase extraction coupled to liquid chromatography–mass spectrometry technologies versus biosensors for monitoring of emerging contaminants in water,” J. Chromatogr. A 1152(1‑2), 97-115.
Rohweder, U. (2003). Arzneimittel in der Umwelt Auswertung der Untersuchungsergebnisse, Environmental and Health Agency, Hamburg, (http://www.blac.de/servlet/is/2146/P-2c.pdf).
Routledge, E. J., and Sumpter, J. P. (1997). “Structural features of alkylphenolic chemicals associated with estrogenic activity,” J. Biol. Chem. 272(6), 3280-3288.
de Rudder, J., Van de Wiele, T., Dhooge, W., Comhaire, F., and Verstraete, W. (2004). “Advanced water treatment with manganese oxide for the removal of 17α-ethynylestradiol (EE2),” Water Res. 38(1), 184-192.
Salste, L., Leskinen, P., Virta, M., and Kronberg, L. (2007). “Determination of estrogens and estrogenic activity in wastewater effluent by chemical analysis and the bioluminescent yeast assay,” Sci. Total Environ. 378(3), 343-351.
Schröder, H. Fr. (2003). “Determination of fluorinated surfactants and their metabolites in sewage sludge samples by liquid chromatography with mass spectrometry and tandem mass spectrometry after pressurized liquid extraction and separation on fluorine-modified reversed-phase sorbents,” J. Chromatogr. A 1020(1), 131-151.
Schröder, H. Fr., José, H. J., Gebhardt, W., Moreira, R. F. P. M., and Pinnekamp, J. (2010). “Biological wastewater treatment followed by physicochemical treatment for the removal of fluorinated surfactants,” Water Sci. Technol. 61(12), 3208‑3215.
Sekar, R., and Wu, H.-F. (2006). “Quantitative method for analysis of monensin in soil, water, and urine by direct combination of single-drop microextraction with atmospheric pressure matrix-assisted laser desorption/ionization mass spectrometry,” Anal. Chem. 78(18), 6306-6313.
Shareef, A., Parnis, C. J., Angove, M. J., Wells, J. D., and Johnson, B. B. (2004). “Suitability of N,O-bis(trimethylsilyl)trifluoroacetamide and N-(tert-butyldimethylsilyl)-N-methyltrifluoroacetamide as derivatization reagents for the determination of the estrogens estrone and 17α-ethinylestradiol by gas chromatography‑mass spectrometry,” J. Chromatogr. A 1026(1-2), 295-300.
Shenker, M., Harush, D., Ben-Ari, J., and Chefetz, B. (2011). “Uptake of carbamazepine by cucumber plants – A case study related to irrigation with reclaimed wastewater,” Chemosphere 82(6), 905‑910.
Shrivas, K., and Wu, H.-F. (2007). “A rapid, sensitive and effective quantitative method for simultaneous determination of cationic surfactant mixtures from river and municipal wastewater by direct combination of single-drop microextraction with AP-MALDI mass spectrometry,” J. Mass Spectrom. 42(12), 1637-1644.
Sinclair, C. J., and Boxall, A. B. A. (2003). “Assessing the ecotoxicity of pesticide transformation products,” Environ. Sci. Technol. 37(20), 4617-4625.
Snyder, S. A., Keith, T. L., Verbrugge, D. A., Snyder, E. M., Gross, T. S., Kannan, K., and Giesy, J. P. (1999). “Analytical methods for detection of selected estrogenic compounds in aqueous mixtures,” Environ. Sci. Technol. 33(16), 2814-2820.
Sowers, A. D., Gaworecki, K. M., Mills, M. A., Roberts, A. P., and Klaine, S. J. (2009). “Developmental effects of a municipal wastewater effluent on two generations of the fathead minnow, Pimephales promelas” Aquat. Toxicol. 95(3), 173-181.
Stackelberg, P. E., Furlong, E. T., Meyer, M. T., Zaugg, S. D., Henderson, A. K., and Reissman, D. B. (2004). “Persistence of pharmaceutical compounds and other organic wastewater contaminants in a conventional drinking-water-treatment plant,” Sci. Total Environ. 329(1-3), 99-113.
Stump, M. J., Jones, J. J., Fleming, R. C., Lay, J. O., and Wilkins, C. L. (2003). “Use of double-depleted 13C and 15N culture media for analysis of whole cell bacteria by MALDI time-of-flight and Fourier transform mass spectrometry,” J. Am. Soc. Mass Spectrom. 14(11), 1306‑1314.
Sudhir, P.-R., Wu, H.-F., and Zhou Z.-C. (2005). “Identification of peptides using gold nanoparticle-assisted single-drop microextraction coupled with AP-MALDI mass spectrometry,” Anal. Chem. 77(22), 7380-7385.
Sulitzky, C., Rückert, B., Hall, A. J., Lanza, F., Unger, K., and Sellergren, B. (2002). “Grafting of molecularly imprinted polymer films on silica supports containing surface-bound free radical initiators,” Macromolecules 35(1), 79‑91.
Sun, P., and Armstrong, D. W. (2010). “Ionic liquids in analytical chemistry,” Anal. Chim. Acta 661(1), 1‑16.
Sun, X., Zhu, Y., Wang, P., Li, J., Wu, C., and Xing, J. (2011). “High temperature and highly selective stationary phases of ionic liquid bonded polysiloxanes for gas chromatography,” J. Chromatogr. A1218(6), 833-841.
Södergren, A. (1987). “Solvent-filled dialysis membranes simulate uptake of pollutants by aquatic organisms,” Environ. Sci. Technol. 21(9), 855‑859.
Söderström, H., Lindberg, R. H., and Fick, J. (2009). “Strategies for monitoring the emerging polar organic contaminants in water with emphasis on integrative passive sampling,” J. Chromatogr. A1216(3), 623-630.
Tan, B. L .L., Hawker, D. W., Müller, J. F., Leusch, F. D. L., Tremblay, L. A., and Chapman, H. F. (2007). “Comprehensive study of endocrine disrupting compounds using grab and passive sampling at selected wastewater treatment plants in South East Queensland, Australia,” Environ. Int. 33(5), 654-669.
Tankeviciute, A., Kazlauskas, R., and Vickackaite, V. (2001). “Headspace extraction of alcohols into a single drop,” Analyst126(10), 1674-1677.
Taylor, P. J. (2005). “Matrix effects: The Achilles heel of quantitative high-performance liquid chromatography–electrospray–tandem mass spectrometry,” Clin. Biochem. 38(4), 328‑334.
Ternes, T. A. (1998a). “Occurrence of drugs in German sewage treatment plants and rivers,” Water Res. 32(11), 3245-3260.
Ternes, T. A., Hirsch, R., Mueller, J., and Haberer, K. (1998b). “Methods for the determination of neutral drugs as well as betablockers and β2-sympathomimetics in aqueous matrices using GC/MS and LC/MS/MS,” Fresenius J. Anal. Chem. 362(3), 329‑340.
Ternes, T. A., Stumpf, M., Mueller, J., Haberer, K., Wilken, R.-D., and Servos, M. (1999). “Behavior and occurrence of estrogens in municipal sewage treatment plants ‑I. Investigations in Germany, Canada and Brazil,” Sci. Total. Environ. 225(1-2), 81‑90.
Ternes, T. A., Bonerz, M., Herrmann, N., Löffler, D., Keller, E., Lacida, B. B., and Alder, A. C. (2005). “Determination of pharmaceuticals, iodinated contrast media and musk fragrances in sludge by LC tandem MS and GC/MS,” J. Chromatogr. A 1067(1-2), 213-223.
Theron, H. B., van der Merwe, M. J., Swart, K. J., and van der Westhuizen, J. H. (2007). “Employing atmospheric pressure photoionization in liquid chromatography/ tandem mass spectrometry to minimize ion suppression and matrix effects for the quantification of venlafaxine and O-desmethylvenlafaxine,” Rapid Commun. Mass Spectrom. 21(10), 1680‑1686.
Titirici, M. M., Hall, A. J., and Sellergren, B. (2003). “Hierarchical imprinting using crude solid phase peptide synthesis products as templates,” Chem. Mater. 15(4), 822‑824.
Tobiszewski, M., Mechlińska, A., Zygmunt, B., and Namieśnick, J. (2009). “Green analytical chemistry in sample preparation for determination of trace organic pollutants,” Trends Anal. Chem. 28(8), 943‑951.
Togunde, O. P., Cudjoe, E., Oakes, K. D., Mirnaghi, F. S., Servos, M. R., and Pawliszyn, J. (2012). “Determination of selected pharmaceutical residues in wastewater using an automated open bed solid phase microextraction system,” J. Chromatogr. A 1262, 34‑42.
Trela, B. C., and Waterhouse, A. L. (1996). “Resveratrol: Isomeric molar absorptivities and stability,” J. Agric. Food Chem. 44(5), 1253-1257.
Unruh, J., Piotrowski, E., Schwartz, D. P., and Barford, R. (1990). “Solid‑phase extraction of sulphametazine in milk with quantitation at low ppb levels using thin‑layer chromatography,” J. Chromatogr. 519(1), 179-187.
Valto, P., Knuutinen, J., and Alén, R. (2012). “Overview of analytical procedures for fatty and resin acids in the paper making process,” BioResources 7(4), 6041‑6076.
Van De Steene, J. C., Mortier, K. A., and Lambert W. E. (2006). “Tackling matrix effects during development of a liquid chromatographic-electrospray ionisation tandem mass spectrometric analysis of nine basic pharmaceuticals in aqueous environmental samples,” J. Chromatogr. A 1123(1), 71-81.
van Doorn, H., Grabanski, C. B., Miller, D. J., and Hawthorne, S. B. (1998). “Solid-phase microextraction with pH adjustment for the determination of aromatic acids and bases in water,” J. Chromatogr. A829(1-2), 223-233.
van der Horst, F.A.L., and Holthuis, J. J. M. (1988). “Study of the derivatization of n-alkylamines with 1-fluoro-2,4-dinitrobenzene in the presence of aqueous cetyltrimethylammonium bromide micelles,” J. Chromatogr. 426, 267-282.
Vian, M. A., Tomao, V., Gallet, S., Coulomb, P. O., and Lacombe, J. M. (2005). “Simple and rapid method for cis– and trans-resveratrol and piceid isomers determination in wine by high-performance liquid chromatography using Chromolith columns,” J. Chromatogr. A1085(2), 224-229.
Vieira, E. R., Pierozan, N. J., Lovison, V. (2006). “Determination of N-nitrosamines and N-nitrosables substances in rubber teats and sothers by GC-TEA,” Braz. Arch. Biol. Technol. 49, 73-77.
Viglino, L., Aboulfadl, K., Prévost, M., and Sauvé, S. (2008). “Analysis of natural and synthetic estrogenic endocrine disruptors in environmental waters using online preconcentration coupled with LC-APPI-MS/MS,” Talanta 76(5), 1088-1096.
Vrana, B., Allan, I. J., Greenwood, R., Mills, G. A., Dominiak, E., Svensson, K., Knutsson, J., and Morrison, G. (2005). “Passive sampling techniques for monitoring pollutants in water,” Trends Anal. Chem. 24(10), 845‑868.
Vuckovic, D., Cudjoe, E., Hein, D., and Pawliszyn, J. (2008). “Automation of solid-phase microextraction in high-throughput format and applications to drug analysis,” Anal. Chem. 80(18), 6870-6880.
Wang, W., Ren, S., Zhang, H., Yu, J., An, W., Hu, J., and Yang, M. (2011). “Occurrence of nine nitrosamines and secondary amines in source water and drinking water: Potential of secondary amines as nitrosamine precursors,” Water Res. 45(16), 4930‑4938.
Wang, Y., Kwok, Y. C., He, Y., and Lee, H. K. (1998). “Application of dynamic liquid-phase microextraction to the analysis of chlorobenzenes in water by using a conventional microsyringe,” Anal. Chem. 70(21), 4610-4614.
Watabe Y., Kondo, T., Morita, M., Tanaka, N., Haginaka, J., and Hosoya, K. (2004). ” Determination of bisphenol A in environmental water at ultra-low level by high-performance liquid chromatography with an effective on-line pretreatment device,” J. Chromatogr. A1032(1‑2), 45‑49.
Wise, R. (2002). “Antimicrobial resistance: Priorities for action,” J. Antimicrob. Chemother. 49(4), 585-586.
Wu, Y.-C., and Huang, S.-D. (1999). “Determination of hydroxyaromatic compounds in water by solid-phase microextraction coupled to high-performance liquid chromatography,” J. Chromatogr. A 835(1‑2), 127-135.
Xu, S., Li, Y., Zou, H., Qiu, J., Guo, Z., and Guo, B. (2003). “Carbon nanotubes as assisted matrix for laser desorption/ionization time-of-flight mass spectrometry,” Anal. Chem. 75(22), 6191-6195.
Yang, Z. -H., Lu, Y. -L., Liu, Y., Wu, T., Zhou, Z. -Q., and Liu, D. -H. (2011). “Vortex-assisted surfactant-enhanced-emulsification liquid–liquid microextraction,” J. Chromatogr. A 1218(40), 7071‑7077.
Yiantzi, E., Psillakis, E., Tyrovola, K., and Kalogerakis, N. (2010). ”Vortex-assisted liquid–liquid microextraction of octylphenol, nonylphenol, and bisphenol-A,” Talanta 80(5), 2057-2062.
Ying, G. -G., and Kookana, R. S. (2003). “Degradation of five selected endocrine-disrupting chemicals in seawater and marine sediment,” Environ. Sci. Technol. 37(7), 1256-1260.
Zacharis, C. K., Christophoridis, C., and Fytianos, K. (2012). “Vortex-assisted liquid–liquid microextraction combined with gas chromatography-mass spectrometry for the determination of organophosphate pesticides in environmental water samples and wines,” J. Sep. Sci. 35(18), 2422‑2429.
Zender, J. A., Stuthridge, T. R., Langdon, A. G., Wilkins, A. L., Mackie, K. L., and McFarlane, P. N. (1994). “Removal and transformation of resin acids during secondary treatment at a New Zealand bleached kraft pulp and paper mill,” Water Sci. Technol. 29(5-6), 105‑121.
Zhang, H., and Henion, J. (1999). “Quantitative and qualitative determination of estrogen sulfates in human urine by liquid chromatography/tandem mass spectrometry using 96-well technology,” Anal. Chem. 71(18), 3955-3964.
Zhang, Z., Hibberd, A., and Zhou, J. L. (2008). “Analysis of emerging contaminants in sewage effluent and river water: Comparison between spot and passive sampling,” Anal. Chim. Acta607(1), 37‑44.
Zhou, Q., Bai, H., Xie, G., and Xiao, J. (2008). “Temperature-controlled ionic liquid dispersive liquid phase micro-extraction,” J. Chromatogr. A 1177(1), 43-49.
Zorita, S., Mårtensson, L., and Mathiasson, L. (2009). “Occurrence and removal of pharmaceuticals in a municipal sewage treatment system in the south of Sweden,” Sci. Total Environ. 407(8), 2760-2770.
Zuehlke, S., Duennbier, U., and Heberer, T. (2004). “Determination of polar drug residues in sewage and surface water applying liquid chromatography-tandem mass spectrometry,” Anal. Chem. 76(22), 6548-6554.
Zwiener, C. (2007). “Occurrence and analysis of pharmaceuticals and their transformation products in drinking water treatment,” Anal. Bioanal. Chem. (2007) 387(4), 1159-1162.
Article submitted: October 10, 2013; Peer review completed: February 20, 2014; Revised version received and accepted, April 10, 2014; Published: May 1, 2014.