Li, T., Cai, J.-b., Gu, L.-b., Ding, T., and Zhou, D.-G. (2013). "Correction factors for a radio frequency-type moisture meter for heat-treated wood," BioRes. 8(4), 5549-5560.

Abstract

Moisture content (MC) has an important effect on the performance of wood in service. In an attempt to rapidly and non-destructively acquire the MC of heat-treated wood, a radio frequency-type moisture meter was used to take the MC of 170, 185, and 200 °C heat-treated Manchurian ash and Mongolian pine wood samples as well as reference (conventional kiln-dried) samples. A linear regression analysis was applied to assess the relationship between the MC values obtained using the meter and those obtained using the oven-dry method by fitting the data points according to the least squares method. From the results of the high coefficients of determination of the regression equation, it was concluded that the meter could be effectively used to obtain the MC of heat-treated wood. Finally, to ensure the simple and reliable application of the meter, the meter correction factors corresponding to each species and heat treatment temperature were calculated and listed.


Download PDF

Full Article

Correction Factors for a Radio Frequency-Type Moisture Meter for Heat-Treated Wood

Tao Li, Jia-bin Cai, Lian-bai Gu, Tao Ding, and Ding-guo Zhou *

Moisture content (MC) has an important effect on the performance of wood in service. In an attempt to rapidly and non-destructively acquire the MC of heat-treated wood, a radio frequency-type moisture meter was used to take the MC of 170, 185, and 200 °C heat-treated Manchurian ash and Mongolian pine wood samples as well as reference (conventional kiln-dried) samples. A linear regression analysis was applied to assess the relationship between the MC values obtained using the meter and those obtained using the oven-dry method by fitting the data points according to the least squares method. From the results of the high coefficients of determination of the regression equation, it was concluded that the meter could be effectively used to obtain the MC of heat-treated wood. Finally, to ensure the simple and reliable application of the meter, the meter correction factors corresponding to each species and heat treatment temperature were calculated and listed.

Keywords: Wood; Heat treatment; Moisture content; Radiofrequency-type moisture meter; Calibration

Contact information: College of Materials Science and Engineering, Nanjing Forestry University, Nanjing, 210037, P.R. China; *Corresponding author: dgzhou@njfu.edu.cn

INTRODUCTION

The moisture content (MC) of wood, defined as the ratio of the weight of water in wood to that of oven-dried wood, has a highly significant effect on wood properties. It is important to the effective utilization of wood that the MC of semi-manufactured or finished wood products be well controlled according to the final conditions of use (Skaar 1988). If not, serious problems of dimensional instability, such as warping, twisting, and cracking, could arise due to the hygroscopicity of the wood. Fortunately, more and more enterprises in China have paid attention to this issue and have taken steps as follows: a conditioned storage, in which environmental conditions of 20 to 30 °C and 40 to 60% RH can be maintained all year around, is used to equalize and retain the MC of wood and wood products at the desired MC level before and after wood processing; a special production line, as shown in Fig. 1 taken from a solid wood flooring factory, has been introduced to manually check the drying quality and MC of kiln-dried planks (the boards with poor performance would be returned to the kiln or conditioned storage for re-drying or re-conditioning) in preparation for subsequent secondary manufacturing operations. Thus, it is essential that a reliable and efficient method of measuring wood MC be developed for use in these two operations. In comparison to the oven-dry method, which is the most precise determination method based on the physical definition of wood MC, MC determination with electric moisture meters is much more practical and convenient for field use, in which the MC of wood and wood products during kiln drying, conditioning, processing, or even in service can be instantly obtained, because they are rapid, non-destructive, economical, and simple to use.

Fig. 1. A special production line for checking the drying quality and MC of kiln-dried planks

Currently, two general types of moisture meters are available in the wood industry. Unlike the conductance-type moisture meter, which has two or four nail-like electrodes that make holes in and slightly destroy the surface of the wood during measurement, the radio frequency-type moisture meter has no need to penetrate the surface of the wood with its surface-contact electrode (James 1988). Therefore, such a device has been mainly used for obtaining the MC values of semi-manufactured or finished wood products around the world.

The principle of operation of the radio frequency-type moisture meter hinges upon a fundamental relationship between MC and the dielectric properties (such as dielectric constant and loss factor) of moist wood. There are some factors that affect the accuracy of the MC measurements by the radio frequency-type moisture meter. For ordinary use at room temperature, the species or density of the wood has been found to be the most significant factor affecting the meter reading (Milota 1994). Douglas-fir was the main species used to calibrate the meter (Gillis et al. 2001; Wu 1997; Milota and Gupta 1996), and the correction factors for other common species based on the values of specific gravity are generally provided in the instruction manual as well as preset in the meter by the manufacturer. Some calibration has been conducted for uncommon or unfamiliar species, and the correction factors have been established, in accordance with a standard procedure for moisture meter calibration recommended by ASTM in D4444 (the newest edition published in 2013), for 13 US southern hardwood species (Shupe et al. 2002), four Brazilian wood species (Gillis et al. 2001), bald cypress (Wu 1997), Dahurian larch (Milota and Gupta 1996), and jelutong (Milota 1991). Meanwhile, there have been other projects developed to establish the meter calibration equations for use on pine woods modified by wood preservation treatments with ACQ, CCA, and several new-generation wood preservatives, in which the linear regression relationships between the meter reading and the oven-dry MC were also found by means of kiln-dried wood (Blakemore et al. 2005, 2008; Smith et al. 2007).

In the last two decades, numerous studies have been reported regarding the thermal modification of wood and wood-based panels (Esteves and Pereira 2009; Srinivas and Pandey 2012; Råberg et al. 2012; Huang et al. 2012; Bazyar 2012; Mendes et al. 2013), as well as some heat treatment methods. Thermowood in Finland, Plato in Netherlands, Rectification and Le Bois Perdure in France, and Oil heat treatment in Germany were successfully developed in industrial practice during the 1990s (Hill 2006). It is generally accepted that the dimensional stability and durability of wood can be significantly improved without the use or impregnation of chemical substances during the heat treatment process at 160 to 240 °C (Esteves and Pereira 2009). Because of the superior properties of the modified wood, heat-treated wood products have been mainly used in outdoor and special indoor applications, such as sauna furnishing and under-floor heating systems that are not suitable for the application of common kiln-dried solid wood. Since 2005, the Wood Drying Laboratory of Nanjing Forestry University has conducted research on the relationships between the process parameters and wood properties of heat-treated wood of Chinese species, and on the design and development of pilot-scale superheated vapor heat treatment kilns (Gu et al. 2007; Li et al. 2009; Ding et al. 2011; Cai et. al 2013). The fruits of these efforts have been effectively applied in the wood industry in the Zhejiang Province of China over the course of the past five years. Commercial modified wood products made of heat-treated wood, such as solid wood flooring, garden furniture, and external cladding and decking, are now seeing extensive activity in the Chinese market.

Currently, there is little information that focuses on the calibration of moisture meters for heat-treated wood. Garrahan (1988) investigated the effects of high-temperature kiln drying at the maximum dry bulb temperature of 116 °C on the conductance-type moisture meter readings of dried wood. However, in contrast to the conditions used in the heat treatment, the high-temperature kiln drying could not induce a significant change in the chemical structure and constitution of the wood cell walls. The aim of the present study was to determine whether the radio frequency-type moisture meter could be readily and reliably used to obtain the MC of heat-treated wood and to establish new correction factors for the meter based on the process parameters of heat treatment temperature and species used.

EXPERIMENTAL

Materials

Conventional kiln-dried and rough-sawn Manchurian ash (Fraxinus mandshurica) and Mongolian pine (Pinus Sylvestris L. var. Mongolica) boards, with nominal thicknesses of 25 mm, were obtained from Zhejiang Shiyou Timber Co. Ltd. in China. All boards were flat-sawn blanks, and their initial moisture contents (MCs) ranged from 9% to 13%. In the laboratory, 15 clear boards of each species were carefully selected for use in the study. To obtain a good comparison of the effects of heat treatment on the dielectric properties of wood, each board was cut and sawn into four end- and edge-matched rectangular samples, each measuring 70 mm in the tangential direction, and 250 mm along the grain. The 15 samples in each group, with four groups per species, were collected and randomly assigned for the following testing: three groups were applied to the next three heat-treatment experiments, and the remainder was used as the reference.

Methods of Heat Treatment and Conditioning

In accordance with the heat-treatment procedure described in a previous study (Cai et al. 2013), three heat-treatment experiments, with temperatures of 170, 185, and 200 °C, were conducted in a small modified laboratory variation of the high-temperature drying kiln, in which superheated vapor was used as both a protection gas and a heat transfer medium. The duration of each experiment was kept to a constant 3 h. Following the heat treatment, to provide a uniform surface on which to place the moisture meter for MC determination, all reference specimens were planed to a thickness of 20 mm. Then, three small cubic wood blocks, with edges of 20 mm, were obtained from one end of each sample to be used to determine the oven-dry density of the sample. The remains of each sample, with dimensions of 20 × 70 × 230 mm3, were the specimens used for the MC determination.

The procedure of conditioning occurred as follows: all specimens were first oven-dried at 60 °C until the MC decreased below 3%. Then, they were placed successively in a laboratory conditioning chamber under four different environments until practical equilibrium was reached at each condition. To speed up the conditioning, the temperature used during this stage was higher than that of the ambient environment, as shown in Table 1. Prior to each MC determination, the specimens were re-conditioned in the conditioning chamber to the target MC at 25 °C and at various relative humidity levels. In this way, the duration of the equilibration of the specimens to each MC level was decreased to about two weeks, and it could also be ensured that the effects of temperature on the moisture meter reading at the time of testing were minimal.

Table 1. Environments Used for Equilibrating Specimen to Four MC Levels

Determination and Analysis of MC by Two Methods

A radio frequency-type PM1-E moisture meter (Merlin, Austria) was used in this study. The MC sensor plate is a 106 mm by 41 mm rectangle located on the backside of the meter. The meter can set the oven-dry density in the range of 0.30 to 1.10 g/cm3 and the penetration depth of waves in the range of 2 to 40 mm according to the wood species and thickness, respectively. It is well known that the density of wood varies greatly within species. To adapt the density setting for each board would be cumbersome and not suitable for field use. Accordingly, the average oven-dry density of each group, as shown in Table 2, was used to calibrate the meter’s density setting for each specimen in the group. At each of the four MC levels, the weight of each equalized specimen was first measured for the calculation of the oven-dry MC based on the standard procedure in ASTM D4442 (2007), and then one non-destructive MC measurement using the meter was made at the center of both planed faces of each specimen, which was supported on wooden sticks at both ends to provide an air gap underneath the specimen. The average value of the two meter readings from each specimen was recorded. Finally, each specimen was oven dried at 103 °C for 48 h, and its weight in the absolutely dried condition was measured and recorded.

Table 2. Average Oven-Dry Density of Each Group Determined and Used in the Measurement of MC Using a Moisture Meter

In accordance with previous studies (Shupe et al. 2002; Gillis et al. 2001; Wilson 1999; Wu 1997; Milota and Gupta 1996; Milota 1991), linear regression analysis was applied to assess the relationship between the MC values obtained by the oven dry method and those obtained using the meter. A regression equation was used to fit the scatter plot data points by the least squares method, with the oven-dry MC as the independent variable and the meter reading as the dependent variable. Its format was as follows:

 ,

where a and b are the regression coefficients, i.e., the slope and intercept, respectively, of the linear regression line.

The correction factors (CFs) for the species and heat treatment temperature were then calculated from the following equation:

RESULTS AND DISCUSSION

The plots of meter reading against oven-dry MC for the reference and heat-treated specimens are illustrated in Fig. 2 for Manchurian ash and Fig. 3 for Mongolian pine. The data points for each group of specimens on the graph are in four clusters, which correspond to four moisture content levels, as practical equilibrium was reached at four different moisture conditions. It is well known that the degradation of hemicelluloses in wood during heat treatment can reduce the amount of free hydroxyl groups that can easily gain moisture from the environment (Brito et al. 2008; Tjeerdsma and Militz 2005). As shown in the two graphs, Table 3, and Table 4, the MC of heat-treated wood was lower than that of conventional kiln-dried (reference) wood at the same moisture condition, and the difference increased with the temperature used in the heat treatment process. Mean-while, it was noticeable that for the same heat treatment temperature, the decline in hygroscopicity was always higher for the heat-treated Manchurian ash specimens than it was for the Mongolian pine specimens; for example, the oven-dry MCs of the reference specimens and 185 °C heat-treated wood equilibrated with the 25 °C and 70% RH moisture environment were 12.75% and 9.12%, respectively, for Manchurian ash and 12.86% and 9.90%, respectively, for Mongolian pine. The results were similar to the conclusions drawn in previous works on the differences in mass loss between heat-treated softwood and hardwood (Aydemir et al. 2011; Pierre et al. 2011).

Fig. 2. Moisture meter reading versus oven-dry MC for the reference specimens and heat-treated wood of Manchurian ash

As shown in the results of the linear regression analysis (see Table 5), the coefficients of determination (R2) for these different groups of specimens ranged from 0.9555 to 0.9805. The high coefficients of determination indicated that the linear regression equations for the heat-treated wood of Manchurian ash and Mongolian pine were quite suitable and that using the radio frequency-type moisture meter is a reliable method for non-destructively determining the MC of heat-treated wood with the same results as obtained with conventional kiln-dried wood. The straight line of y=x, which is the best and ideal fit for the calibration of moisture meters, would be fitted were the oven-dry MC measurement equal to the meter reading. However, as a general rule of thumb, the wood industry accepts an error range for the difference between electric moisture reading and actual MC (i.e., oven-dry MC) of no more than ±1% (Milota and Gupta 1996), which corresponds to the area between the two dashed lines of y=x+1 and y=x-1 in Figs. 2 and 3.

Table 3. Average MC Value for Each Group of Manchurian Ash at Different Conditions by Two Methods

Fig. 3. Moisture meter reading versus oven-dry MC for the reference specimens and heat-treated wood of Mongolian pine

Table 4. Average MC Value for Each Group of Mongolian Pine at Different Conditions by Two Methods

Table 5. Results of Linear Regression Analysis

The scatter plot of data points shown in Figs. 2 and 3 and the linear regression equation for the reference (conventional kiln-dried) samples of Manchurian ash and Mongolian pine wood indicated that the meter reading need not be transferred and that the actual MC could be taken directly without any correction. At the same time, it is obvious that the data points corresponding to three temperatures of heat-treated wood of the two species are scattered outside the above-mentioned area. Some possible mechan-isms for the difference between the kiln-dried and heat-treated wood could be partially explained as follows:

  1. In previous related research on the relationships between wood and moisture it was concluded that the most stable bonds were between the wood cell walls and mono-molecular moisture (Skaar 1988), which would have no positive contribution to the dielectric parameters of moist wood (Torgovnikov 1993). Because the hydroxyl group sites, which can easily be occupied by primary water, decrease during the heat treatment process (Brito et al. 2008; Tjeerdsma and Militz 2005), the ratio of monomolecular moisture to total moisture in heat-treated wood should decline, and consequently, the whole dielectric constant of heat-treated wood will be larger than that of kiln-dried wood at the same MC.
  2. Certain chemical reactions occur during the heat treatment process (Esteves and Pereira 2009), and some new substances, such as furfural (Peters et al. 2008), formic acid (Sundqvist et al. 2006), and methanol (Bourgois and Guyonnet 1988), have been observed to form in wood. At 20 °C, the dielectric constants of these substances are about 42, 57, and 34, respectively (Gokel 2004), far higher than that of oven-dried wood, of which the dielectric constant was recorded to be only 2 (Skaar 1988). The free radicals that formed (Ahajji et al. 2009), the decreased pH values, and the increasing acidity of wood caused by the heat treatment process (Awoyemi et al. 2009) also promote the interaction between heat-treated wood and the external electric field.

These factors, dominated by the heat treatment temperature, had an integrative influence on the meter’s reading for heat-treated wood, resulting in higher readings by the moisture meter relative to the measurements gained by the oven-dry MC method, a difference that increased with heat treatment temperature, as shown in Tables 3 and 4. Therefore, to accurately acquire the MC of heat-treated wood using the radiofrequency-type moisture meter, the corrections factor for the meter reading, tabulated in Table 6, should be pre-calculated by subtracting the predicted value of the regression equation from the oven-dry MC and then by applying this value to the meter reading. For example, if a 12% MC reading was obtained from the moisture meter placed on the 185 °C heat-treated ash wood, then the actual MC could be obtained as 12 – 2.52 = 9.48%.

Table 6. Correction Factors for Heat Treatment Temperature and Species Used

From Table 6, as expected from the results of the slopes and intercepts of wood heat-treated at different temperatures listed in Table 5, it can be seen that the absolute value of correction factors ranged from 1.18% to 3.84%, with the absolute value increasing as heat treatment temperature increased. Meanwhile, it was also evident that the absolute value of correction factors for heat-treated Manchurian ash specimens were always higher than those for heat-treated Mongolian pine specimens at the same meter reading and heat treatment temperature, e.g., 3.65% versus 2.60% for 200 °C heat-treated wood that produced a 10% meter reading. The result was the same regarding the above-mentioned differences in the decline of hygroscopicity between the heat-treated woods of these two species. As Aydemir et al. (2011) and Pierre et al. (2011) pointed out, at the same heat-treatment conditions, the effects of the treatment on the wood properties of softwood and hardwood were different. This may have been due to the differences in the proportions, especially regarding hemicelluloses, of the wood chemical compositions that are more susceptible to thermal degradation during the heat treatment process.

CONCLUSIONS

  1. The radio frequency-type moisture meter readings were higher than the actual MCs for the heat-treated wood. The difference increased with heat treatment temperature, and the difference was always higher for hardwood than it was for softwood. The different effects of heat treatment on the wood properties because of the different chemical compositions of the woods could be seen as the main reason for the observed difference.
  2. Based on the fact that correction factors can be previously determined, it may be feasible to use the radio frequency-type moisture meter for a determination of the actual MC of heat-treated wood.
  3. In contrast to kiln-dried wood, heat treatment condition, in addition to wood species and density, should also be taken into consideration for the calibration of moisture meters for heat-treated wood.

ACKNOWLEDGMENTS

The authors are grateful for the support of the Innovative Research Program for Postgraduates in Universities of Jiangsu Province (CXZZ13_0541), the “948” Project from the State Forestry Administration of China (2011-4-12), and the Priority Academic Program Development of Jiangsu Higher Education Institutions (PAPD). The authors would also like to thank Associate Professor Deng-yun Tu of South China Agricultural University (SCAU) and Mr. Xue-li Yu and Mr. Ming-jun Wang of Zhejiang Shiyou Timber Co. Ltd. for their cooperation and support for our research in the last years.

REFERENCES CITED

Ahajji, A., Diouf, P. N., Aloui, F., Elbakali, I., Perrin, D., Merlin, A., and George, B. (2009). “Influence of heat treatment on antioxidant properties and colour stability of beech and spruce wood and their extractives,” Wood Sci. Technol. 43(1-2), 69-83.

ASTM Standard D 4442, (2007). “Standard test methods for direct moisture content measurement of wood and wood-base materials,” ASTM International. West Conshohocken, PA, DOI: 10.1520/D4442-07.

ASTM Standard D 4444-13, (2013). “Standard test method for laboratory standardization and calibration of hand-held moisture meters,” ASTM International. West Conshohocken, PA, DOI: 10.1520/D4444-13.

Awoyemi, L., Jarvis, M. C., and Hapca, A. (2009). “Effects of preboiling on the acidity and strength properties of heat-treated wood,” Wood Sci. Technol. 43(1/2), 97-103.

Aydemir, D., Gunduz, G., Altuntaş, E., Ertas, M., Şahin, H. T., and Hakki Alma, M. (2011). “Investigating changes in the chemical constituents and dimensional stability of heat-treated hornbeam and Uludag fir wood,” BioResources 6(2), 1308-1321.

Bazyar, B. (2012). “Decay resistance and physical properties of oil heat treated aspen wood,” BioResources 7(1), 696-705.

Blakemore, P. A., Morrow, A., and Ngo, D. (2008). “Moisture meter corrections for ACQ treated pine,” Forest & Wood Products Australia Limited (PN07.2045).

Blakemore, P. A., Morrow, A., Liew, W., Muruganathan, M., and Luff, R. (2005). “Species and CCA treatment corrections for hand-held moisture meters with radiata and slash pine,” Forest & Wood Products Research & Development Corporation (PN04.2002).

Bourgois, J., and Guyonnet, R. (1988). “Characterization and analysis of torrefied wood,” Wood Sci. Technol. 22(2), 143-155.

Brito, J. O., Silva, F. G., Leão, M. M., and Almeida, G. (2008). “Chemical composition changes in eucalyptus and pinus woods submitted to heat treatment,” Bioresource Technology 99(18), 8545-8548.

Cai, J., Yang, X., Cai, L., and Shi, S. Q. (2013). “Impact of the combination of densification and thermal modification on dimensional stability and hardness of poplar lumber,” Drying Technology 31(10), 1107-1113.

Ding, T., Gu, L., and Liu, X. (2011). “Influence of steam pressure on chemical changes of heat-treated Mongolian pine wood,” BioResources 6(2), 1880-1889.

Esteves, B. M., and Pereira, H. M. (2009). “Wood modification by heat treatment: A review,” BioResources 4(1), 370-404.

Garrahan, P. (1988). “Moisture meter correction factors for high temperature dimension lumber,” in: Proceedings of the 39th Western Dry Kiln Association Meeting, Reno, Nevada.

Gillis, C. M., Stephens, W. C., and Peralta, P. N. (2001). “Moisture meter correction factors for four Brazilian wood species,” Forest Prod. J. 51(4), 83-86.

Gokel, G. W. (2004). Dean’s Handbook of Organic Chemistry (Second Edition), McGraw-Hill, New York.

Gu, L., Li, T., Tu, D., and Jiang, N. (2007). “Research and application of heat-treatment of solid wood flooring,” in: Proceedings of 10th International IUFRO Division 5 Wood Drying Conference, Orono, Maine.

Hill, C. A. S. (2006). Wood Modification: Chemical, Thermal and Other Processes, John Wiley & Sons Ltd., Chichester, West Sussex, England.

Huang, X., Kocaefe, D., Kocaefe, Y., Boluk, Y., and Pichette, A. (2012). “Changes in wettability of heat-treated wood due to artificial weathering,” Wood Sci. Technol. 46(6), 1215-1237.

James, W. L. (1988). “Electric moisture meters for wood,” General Technical Report (FPL-GTR- 6), USDA Forest Service, Forest Products Laboratory, Madison, WI.

Li, T., Gu, L., and Jiang, N. (2009). “Effect of high temperature heat treatment on ash wood color,” Scientia Silvae Sinicae 45(12), 149-153.

Mendes, R. F., Júnior, G. B., de Almeida, N. F., Surdi, P. G., and Barbeiro, I. N. (2013). “Effect of thermal treatment on properties of OSB panels,” Wood Sci. Technol. 47(2), 243-256.

Milota, M. R. (1991). “Correction factors for moisture-meter measurements of jelutong (Dyera costulata),” Forest Prod. J. 41(2), 49-50.

Milota, M. R. (1994). “Specific gravity as a predictor of species correction factors for a capacitance-type moisture meter,” Forest Prod. J. 44(3), 63-68

Milota, M. R., and Gupta, R. (1996). “Moisture meter correction factors for Dahurian larch from the Russian far east,” Forest Prod. J. 46(6), 91-93.

Peters, J., Fischer, K., and Fischer, S. (2008). “Characterization of emissions from thermally modified wood and their reduction by chemical treatment,” BioResources 3(2), 491-502.

Pierre, F., Almeida, G., Brito, J. O., and Perré, P. (2011). “Influence of torrefaction on some chemical and energy properties of maritime pine and pedunculate oak,” BioResources 6(2), 1204-1218.

Råberg, U., Daniel, G., and Terziev, N. (2012). “Loss of strength in biologically degraded thermally modified wood,” BioResources 7(4), 4658-4671.

Shupe, T. F., Wu, Q., and Hartley, I. D. (2002). “Calibration of moisture meters for southern hardwoods,” Forest Prod. J. 52 (7/8), 59-62.

Simpson, W. T. (1973). “Predicting equilibrium moisture content of wood by mathematical models,” Wood and Fiber Science 5(1), 41-49.

Skaar, C. (1988). Wood-Water Relations, Springer-Verlag Berlin Heidelberg, New York.

Smith, W. B., Yeo, H., Morey, B., Stark, C., Tascioglu, C., Schneider, P. F., Herdman, D., and Freeman, M. (2007). “Development of moisture meter correction factors for use with preservative treated wood,” in: Proceedings of 10th International IUFRO Division 5 Wood Drying Conference, Orono, Maine.

Srinivas, K., and Pandey, K. K. (2012). “Effect of heat treatment on color changes, dimensional stability, and mechanical properties of wood,” Journal of Wood Chemistry and Technology32(4), 304-316.

Sundqvist, B., Karlsson, O., and Westermark, U. (2006). “Determination of formic acid and acetic acid concentrations formed during hydrothermal treatment of birch wood and its relation to colour, strength and hardness,” Wood Sci. Technol. 40(7), 549-561.

Tjeerdsma, B. F. and Militz, H. (2005). “Chemical changes in hydrothermal treated wood: FTIR analysis of combined hydrothermal and dry heat-treated wood,” Holz als Roh-und Werkstoff 63(2), 102-111.

Torgovnikov, G. I. (1993). Dielectric Properties of Wood and Wood-based Materials, Springer-Verlag, New York.

Wilson, P. J. (1999). “Accuracy of a capacitance-type and three resistance-type pin meters for measuring wood moisture content,” Forest Prod. J. 49(9), 29-32.

Wu, Q. (1997). “Calibration of moisture meters for bald cypress (Taxodium distichum),” Forest Prod. J. 47(10), 77-78.

Article submitted: August 8, 2013; Peer review completed: September 10, 2013; Revised version received and accepted: September 12, 2013; Published: September 16, 2013.