NC State
BioResources
Lv, Q., Wang, J., and Lu, Y. (2024). "Prestressed wood or bamboo structures: Historical overview and state-of-the-art," BioResources 19(4), 9964-10004.

Abstract

This review explores the evolution of prestressed timber/bamboo structures across component, connection, and structural levels, and it examines the corresponding performance of prestressed specimens. Firstly, the utilization of prestress in beams is achieved through either pre-bending methods or the incorporation of additional components. Subsequently, prestress in timber/bamboo columns often appears in the form of lateral confinement, which improves the compressive performance of the columns. On the structural level, prestress is applied in self-centering structural systems and large-span string timber/bamboo structures. Detailed schematic diagrams illustrate the application methods and underlying principles of prestress in timber/bamboo components and structures. Based on the current state of research, the future research needs and development directions are outlined. The research aims to promote the broader application of prestressed timber/bamboo structures in practical engineering, contributing to the advancement of sustainable building practices.


Download PDF

Full Article

Prestressed Wood or Bamboo Structures: Historical Overview and State-of-the-Art

Qingfang Lv, Juewen Wang, and Yujie Lu *

This review explores the evolution of prestressed timber/bamboo structures across component, connection, and structural levels, and it examines the corresponding performance of prestressed specimens. Firstly, the utilization of prestress in beams is achieved through either pre-bending methods or the incorporation of additional components. Subsequently, prestress in timber/bamboo columns often appears in the form of lateral confinement, which improves the compressive performance of the columns. On the structural level, prestress is applied in self-centering structural systems and large-span string timber/bamboo structures. Detailed schematic diagrams illustrate the application methods and underlying principles of prestress in timber/bamboo components and structures. Based on the current state of research, the future research needs and development directions are outlined. The research aims to promote the broader application of prestressed timber/bamboo structures in practical engineering, contributing to the advancement of sustainable building practices.

DOI: 10.15376/biores.19.4.Lv

Keywords: Timber/Bamboo structures; Prestress; Beams; Columns; Self-centering systems; String structures

Contact information: Key Laboratory of Concrete and Prestressed Concrete Structures of the Ministry of Education, Southeast University, Nanjing 210096, China; *Corresponding author: 230218117@seu.edu.cn

GRAPHICAL ABSTRACT

INTRODUCTION

Timber/bamboo structures, as an ancient architectural form, have played an essential role in construction since primitive societies and continue to exert influence to this day. The 67-meter Yingxian Wooden Pagoda, completed in 1056, has been preserved for thousands of years and has served as a representative example of ancient timber construction techniques (Liu and Yang 2019). The Forbidden City in Beijing, one of the most emblematic collections of ancient timber structures, employed exquisite mortise, tenon joints, and bracketing systems (Paliszewska-Mojsiuk 2018). This configuration ingeniously alleviated impacts caused by earthquakes, thereby ensuring the structure’s stability and safety (Gustafson et al. 2008). In the 1840s, Chicago, USA, witnessed the emergence of lightweight timber frame houses constructed using 38 mm thick timber, assembled with long nails (De Geetere and Ingelaere 2014). This lightweight timber frame structure has progressively become one of the most predominant architectural forms for low-rise housing, dormitories, and hotels (Caniato et al. 2017). The Dai’s bamboo house in China represents a typical example of traditional bamboo architecture. The connection method involves the tying of bamboo rafters, characterized by the use of local materials, effective ventilation and moisture prevention, and high spatial efficiency (Sattar 1995). In contrast, the Naman Conference Center in Da Nang, Vietnam, integrates bamboo with modern materials including glass and steel, offering new solutions to current environmental challenges (Thi et al. 2017).

In the latter half of the 19th century, the demand for large-scale infrastructure facilitated the emergence and utilization of steel and reinforced concrete (Yeoh et al. 2011). Due to the limited industrial technological capabilities of timber/bamboo structures at that time, they gradually receded from the purview of construction engineering (Omenzetter et al. 2011). Nevertheless, since 1950, timber/bamboo materials have experienced a resurgence in construction practices (Aloisio et al. 2023b). The use of bamboo in foundations, doors, windows, and walls has progressively increased, enabling nearly all parts of a house, to be constructed using bamboo except fireplaces and chimneys (McClure 1956). The distribution of timber architecture in England was summarized by Smith (1965), highlighting the distinctions and connections among different regional forms of timber structures. Timber planks can be widely applied in farm buildings such as sheds, barns, silos, and granaries (Banks 1972). Timber arch bridges and timber truss bridges also became increasingly common starting from the 1980s (Duwadi and Ritter 1997; Totman 1983; Verna et al. 1984). The reasons for this revival can be attributed to the following two aspects:

  1. The rise of the green and sustainable development concept

In recent years, the green and sustainable development concept has prompted a reassessment of traditional materials’ environmental impact in construction engineering (Abdulhameed et al. 2023). Studies on timber/bamboo materials have shown that they are associated with low carbon emissions and energy consumption during growth and processing (Lim et al. 2023). Additionally, buildings with timber/bamboo materials exhibit excellent insulation properties, resulting in outstanding lifecycle carbon emissions and energy utilization efficiency (Dodoo et al. 2014; Robati and Oldfield 2022). These advantages have driven the application of timber/bamboo structures in green buildings.

(2) Development of modern bio-materials

Natural wood is susceptible to decay, with irregular shapes and varying mechanical properties. Its mechanical performance is significantly impacted by environmental factors such as temperature and humidity, making it unsuitable for use in some aspects of construction (Bartlett et al. 2019; Cui et al. 2024). Against this background, engineered timber/bamboo materials have gradually emerged, such as glulam-laminated timber (GLT), cross-laminated timber (CLT), and laminated veneer lumber (LVL). GLT, which dates back to 1870, involves bonding solid timber sections together in the same direction through gluing (Kim et al. 2011). Each layer of timber in CLT is glued perpendicularly to the adjacent layers, providing uniform strength in both directions (Huang et al. 2022; Bai et al. 2024). LVL is a single-layer board with the grain oriented in the same direction, which has a better mechanical performance than common GLT (Zhu et al. 2007; (Ardalany et al. 2011). Given the scarcity of timber and the abundance of bamboo resources in some areas, various engineered bamboo materials, such as glulam-laminated bamboo (GLB), cross-laminated bamboo (CLB), and laminated veneer bamboo (LVB), have been proposed (Lee et al. 1998; Liu et al. 2016; Chen et al. 2022). Due to the superior mechanical properties of bamboo fibers, engineered bamboo materials manufactured from them exhibit higher density, elasticity, and strength compared to timber (Chen et al. 2022; Tian et al. 2023), and the bending strength of GLB is higher than that of CLB (Sinha et al. 2014).

Although engineered timber/bamboo materials are economical and practical, effectively addressing the defects of natural wood, the promotion of timber/bamboo structures still faces challenges. Firstly, the fire resistance of bamboo and timber is directly related to the safety of occupants in buildings. Published research has employed the charring rate to measure the fire resistance of timber/bamboo materials (Schmid et al. 2014; Xu et al. 2015; Zhang et al. 2019). Based on the Reduced Cross Section Method (RCSM), novel fire design models for glulam timber/bamboo have been proposed to provide significant references for modern bamboo and timber engineering (Xu et al. 2018; Cui et al. 2023).

Furthermore, compared with steel or concrete materials, the relatively lower mechanical performance and brittle failure mode of timber/bamboo materials limit the development of timber/bamboo structures towards long spans, high-rise, and large-scale applications (Li et al. 2019; Wang et al. 2024). Existing research has explored additional components, such as FRP plates (Canning and Luke 2008; Colombi and Fava 2015; Stratford and Cadei 2006), strips (Motavalli et al. 2010; Khedmatgozar Dolati and Mehrabi 2022), bars (Cheng et al. 2018; Hadhood et al. 2021; Wdowiak-Postulak et al. 2023), or steel strands (Ranzi and Ostinelli 2017; Zhang et al. 2022) for reinforcing timber/bamboo elements, but their combined efficiency still requires improvement.

Additionally, despite the high strength-to-weight ratio of timber/bamboo materials, which offer higher utilization efficiency compared to low-carbon steel and ordinary concrete (Crocetti 2016), many experimental investigations have shown that failures in timber/bamboo structures are mainly concentrated in the connection areas. The connection methods, joint stiffness, and bearing capacity directly impact the overall performance of prefabricated timber/bamboo structures. Although many new modern connection methods have been proposed, such as nail connections (Gattesco and Boem 2016; Ruan et al. 2022), screw connections (Hossain et al. 2016; Schiro et al. 2018), bolted connections (Lam et al. 2010; Quenneville and Mohammad 2000; Song et al. 2017; Cui et al. 2024), and self-tapping wood screws (Li et al. 2017; Petrycki et al. 2020; Cui et al. 2022), the most suitable connection for improving the brittle characteristics of timber/bamboo structures still needs to be studied.

To solve the issues mentioned above, prestress technology, which has served as a main reinforcement approach for concrete structures (Akl et al. 2017; Gao et al. 2017), is introduced into timber/bamboo structures for the enhancement of structural components. The introduction of prestress can significantly enhance the fire resistance of glulam timber or bamboo, with the degree of enhancement positively correlated with the magnitude of prestress (Quiquero et al. 2020; Zhang et al. 2024). In the research on mechanical properties, extended research has demonstrated the effectiveness of prestress in improving strength and stiffness, reducing deflection, and optimizing tress distribution. Additionally, prestress technology is also utilized in the connections of timber /bamboo structures to improve overall stress and deformation patterns, enhancing the vertical load-bearing and seismic performance of structures. This advancement promotes the development of large-span and high-rise buildings.

This study provides an overview of the methods for applying prestressing technology in timber/bamboo structures at the component, connection, and structural levels and the corresponding performance of the prestressed specimens. By summarizing the characteristics of existing research, this paper identifies the directions to be explored, particularly in the lack of research on efficient reinforcement for timber/bamboo materials, unestablished prestress loss standards, and the actual seismic performance. This review points out future research directions, providing theoretical references for engineering applications.


THE ORIGIN OF PRESTRESS IN TIMBER/BAMBOO STRUCTURES

A prestress condition exists early in the growth process of trees. The stress associated with the expansion of cross-sections during germination is referred to as growth stress. The causes and distribution characteristics of growth stress in trees were first discussed by Münch (1938) and Jacobs (1938). Growth stress was observed to be unevenly distributed radially along the cross-section, with compressive prestress generated at the center and tensile prestress at the outmost edges, as shown in Fig. 1(a). Due to the susceptibility of buckling under compression for wood fibers (Boyd 1950), the compressive strength along the grain is typically only about half of its tensile strength. Commonly, wind or seismic loads result in a bending response in trees, causing tension on one side and compression on the other side of the cross-section, as illustrated in Fig. 1(b). After the superimposition of growth and bending stress states, compressive stress on the compression side is mitigated while tensile stress on the tension side increases, as illustrated in Fig. 1(c). The utilization of the mechanical properties and overall load-bearing capacity are improved.

In ancient times, tents constructed with tensioned bent slender branches to resist wind loads exemplified an early application of prestress in timber/bamboo structures (Gasparini 2006). Wedge connection was a significant traditional structure connection form (Gustafson et al. 2008). A wedge was a small wooden peg with a thick top and sharp bottom. Its tip was inserted into a gap in the connection, and the flat end was struck with a heavy object driving the wedge deeper (Yang et al. 1999), as shown in Fig. 2(a). The gaps expanded and prestressed to achieve fixing and connection. Grubenman combined wedges with iron straps to construct the first laminated timber arch (James 2017). The Wettingen Bridge, built in 1765, was based on this principle, as shown in Fig. 2(b) (Caldenby 2018). The basic wedges were improved by incorporating iron straps, with additional tensile strength and stability added to the bridge.

Fig. 2. Evolution of prestressed timber bridges

In the 19th century, the rapid expansion of American railroads drove the further development of prestressed timber bridges (Wipf et al. 2000). It began with Lon’s patent for a timber truss bridge (Long 1830), as shown in Fig. 2(c), where counterbraces applied prestress using wedges (Gasparini and Simmons 1997a,b; Gasparini 2006; Gasparini et al. 2006). This method incorporated engineering mathematical principles to distribute loads and stresses within the structure better. However, it was soon superseded by Howe’s new patent (Howe 1840), which introduced pre-tensioned iron tendons into the truss, as illustrated in Fig. 2(d) (Sutherland 2016). The introduction of iron tendons also facilitated the construction of more standardized and reliable bridges.

Timber/bamboo structures have gradually evolved into modern large-span structural systems represented by glued laminated timber structures (D’Aveni and D’Agata 2017; Li et al. 2019; Jia 2022). The development of prestress in timber/bamboo structures is exhibited in Fig. 3. The review of timber/bamboo structures in the following sections is divided into the following main sections in order from components to structures: (1) Prestressed timber/bamboo beams; (2) Prestressed timber/bamboo composite columns; (3) Timber/bamboo lateral resistance structural systems adopting prestress technology; and (4) Prestressed technology in large-span timber structural systems. The methods of prestress applied and the effects it contributed to in timber/bamboo components, connections, and structures are discussed in detail.

Fig. 3. Development of prestress in timber/bamboo structures

 

PRESTRESSED TIMBER/BAMBOO BEAMS

Applying Prestress through Pre-arching

The elastic modulus and strength of timber/bamboo materials are relatively lower compared with steel and concrete, making timber/bamboo beams prone to deformation and brittle bending failure (Zheng et al. 2021; Arafat and Imam 2022). Therefore, various prestressing techniques have been introduced to enhance the mechanical performance of timber/bamboo beams or other bending components. One common method is applying external loads to achieve pre-arching, as shown in Fig. 4(a). After flipping, the pre-arched timber beam experiences tension in the upper flange and compression in the lower flange, resulting in improved flexural load capacity (De Luca and Marano 2012).

In 2005, Borri et al. (2005) attained prestress in beams through the three-point bending test, with the stress intensity corresponding to about 25 to 35% of the ultimate timber flexure strength. The Preflex process was first implemented in prestressed concrete beams, applying symmetric four-point bending loads to achieve a more uniform stress distribution in flexural members. The Preflex cambering method for timber flexure members was proposed by Morano and Mannini (2006). In this method, the bottom of the beam was turned upwards before a two-point load was applied. The end anchors were tightened when the deformation of the GLT beam reached the predicted value and a pre-arched beam was achieved after rotating. Moreover, Lehmann (2015) and Negrão (2016) achieved beam cambering using an adjustable support that can move up and down, creating a triangular moment distribution in the beam, as shown in Fig. 4(b). However, due to the excessive support force and bearing displacement required, it was not suitable for large-size beams.

Fig. 4. Main forms of pre-arched timber/bamboo beams

Anshari and associates (Anshari et al. 2012; Anshari and Guan 2014; Anshari 2015) conducted a series of research on inducing camber in timber beams using the moisture-dependent swelling nature of compressed wooden (CW) blocks since 2012. The researchers cut rectangular holes at the top of GLT beams and inserted CW blocks with low moisture content to induce camber through hygroscopic swelling, as shown in Fig. 4(c). Significant initial tensile stress at the top and compressive stress at the bottom of the beam was generated. Compared with non-prestressed beams, beams with three 45mm CW blocks had flexural stiffness increased by 19% and the load-bearing capacity increased by 14%. In 2017, Anshari and Guan (2017) further validated the effects of the thickness and depth of CW blocks on initial flexural stiffness and the ultimate load-bearing capacity of beams through finite element analysis. The results illustrated that increasing the thickness and insertion depth of CW blocks could enhance the initial flexural stiffness of the beam by an average of 20%, but the improvement in ultimate flexural load capacity was relatively limited. Müller and associates (Müller 2020; Müller et al. 2021) applied Anshari’s method to timber-concrete composite components to reduce the buckling of timber elements caused by cast-in-place concrete.

In 2023, Zhang et al. (2023) presented a pioneering concept that utilized the laminated interaction between layered timber/bamboo components with different curvatures to generate prestress, as shown in Fig. 4(d). A single layer of bamboo was glued and bent in a curved arc-shaped mold and then bonded with a straight glulam beam to form a composite component. In this process, the pre-bent laminated bamboo layer was straightened, and prestress was stored within it. The study found that compared with non-prestressed beams, the bending performance of sandwich beams with top and bottom laminated bamboo layers was obviously improved, showing a shift in failure mode from brittle tensile to ductile failure.

Applying Prestress through Additional Components

In addition to the aforementioned cambering methods, using additional prestressed components to reinforce timber/bamboo beams is also a widely cited effective method (Garas and Chalmers 1980; Gessner et al. 2019). The forms of additional prestressed components include prestressed steel bars (Chen et al. 1998; De Luca and Marano 2012), steel strands (Guo et al. 2021; Zhang et al. 2022), FRP materials (Achintha and Balan 2019; Breveglieri and Czaderski 2021; Custódio and Cabral-Fonseca 2023), etc. The methods of combining prestressed components with main load-bearing beams include internal unbonded or bonded methods (Al-Emrani and Kliger 2006; Capozucca 1998; Yi et al. 2015), and the Near Surface Mounted (NSM) method (Al-Saadi et al. 2017; Rocha et al. 2023), etc.

Post-tensioned steel bars or wires

Fig. 5. Post-tensioned steel bars or wires strengthen bamboo/timber beams

In 1962, Bohannan first proposed the idea of using prestressed high-strength steel bars or strands in timber/bamboo structures to improve mechanical performance. Peterson (1965) used epoxy resin to bond prestressed steel bars on the tension side of timber beams in 1965. Song et al. (2002) drilled holes at the end of timber beams and placed 4 mm diameter round steel bars at the bottom edge, then applied prestress by tightening nuts, as shown in Fig. 5(a). De Luca and Marano (2012) used mechanical tensioning devices to apply a pre-tension force of 18 kN to steel bars, then bonded the bars with adhesive into the bottom grooves of beams as external prestress reinforcement, as shown in Fig. 5(b). The stiffness and ultimate load capacity of the beams increased by 37.9% and 40.2% respectively, and the ductility increased by 79.1% compared to unreinforced components.

Negrão et al. (2016) discussed the effects of pre-tensioning and post-tensioning methods on beams reinforced with prestressed bars. The adhesive was required in the pre-tensioning method, while the steel bars were anchored at the beam ends using mechanical devices before applying prestress in the post-tensioning method. The long-term fatigue risk of the adhesive interface in the pre-tensioning method made post-tensioned bars more suitable for practical engineering applications. Liu et al. (2008) discovered that setting post-tensioned bars in the tension section improved the ultimate load capacity significantly, whereas the improvement in stiffness was imitated. Wei et al. (2020) and Tian et al. (2021, 2023) found that embedding post-tensioned steel bars in bamboo beams enhanced stiffness, load-bearing capacity, and material efficiency. However, the influence of prestress level on ultimate load capacity was limited under the same reinforcement ratio.

The selection of bonded and unbonded prestressed tendons directly affects the overall performance of flexural members. Bonded prestressed tendons form an integral whole with beams by using adhesive (Al-Emrani and Kliger 2006; Hahn et al. 2019), while unbonded prestressed tendons transmit prestress directly through end anchorage, avoiding potential negative impacts from the adhesive (Bedriñana et al. 2021; Bu and Wu 2018). McConnel et al. (2014) studied the flexural performance of bonded and unbonded linear prestressed glulam beams, finding that unbonded prestressed timber beams contributed to a 17.6% and 8.1% rise in load-bearing capacity and stiffness respectively. Meanwhile, bonded prestressed increased about 40.1% in load-bearing capacity and 30.0% in stiffness, showing a more significant improvement in beam performance. Christoforo et al. (2022) conducted similar experiments, finding that failure mode changed from tension fiber rupture to compression fiber buckling and wrinkling.

Steel strands possess higher tensile strength compared to steel bars, and they are also widely used in the external prestress reinforcement of bending components, as shown in Fig. 5(c). Yang et al. (2016) applied prestress to steel strands using a jack. The GLT beams reinforced with externally prestressed steel strands showed significant improvements in ultimate load-bearing capacity and flexural stiffness. Prestressed steel strands also changed the brittle tensile failure mode into ductile compressive yielding failure mode. Guo et al. (2018) studied the short-term and long-term bending deflections of bamboo-timber composite beams reinforced with prestressed steel strands. Under the same external load level, prestress could reduce costs effectively by saving 13.3% to 52.0% on bamboo-timber composite materials. Additionally, the application of prestress effectively reduced the long-term deflection of composite beams. Zhang et al. (2022) proposed a new steel-bamboo composite beam strengthened with externally prestressed steel strands tensioned by cross-core jacks. Test results indicated that two-point prestressed specimens exhibited better deformation performance and higher loading-bearing capacity than the one-point prestressed specimens.

FRP materials

Fiber Reinforced Polymer (FRP) materials, characterized by high strength, good ductility, lightweight, and corrosion resistance, have been widely used in the reinforcement of building structures. With successful applications of prestressed FRP materials in concrete, attempts have been made to reinforce timber/bamboo structures with FRP materials. The common reinforcement practice was achieved by gluing (usually epoxy resin) sheets, plates, bars, etc., to timber beams.

According to the bonding position, FRP reinforcement of bamboo-timber beams can be categorized into five forms, as shown in Fig. 6. The method (a) in Fig. 6 directly performs in-situ flexural reinforcement (Johnsson et al. 2007), which is relatively convenient for construction. Based on method (a), FRP can also be fixed inside the beam, and this modified method (b) in Fig. 6 can be directly incorporated into the production process of glued-laminated timber. Method (c) utilizes thin FRP sheets to wrap the entire timber beam, allowing reinforcement in cases of partial timber degradation and cracking. In methods (d) and (e), the bottom of the timber beam is slotted and FRP bars are inserted.

Fig. 6. Types of strengthening beams with FRP

Numerous studies have employed pre-tensioned FRP bars to reinforce timber/bamboo components. Johnsson et al. (2007) adhered carbon fiber reinforced polymer (CFRP) bars to the bottom grooves of beams with epoxy adhesive, validating the Near Surface Mounted (NSM) method for timber components. Ahmad (2010) applied prestress to GFRP bars by mechanical tensioning. The bending performance of timber beams reinforced with bonded glass fiber (GFRP) bars was studied, showing enhancements in both load-bearing capacity and stiffness after reinforcement. Lv et al. (2019) proposed a one-step forming method suitable for large-scale factory production to produce prestressed bamboo beam specimens. The one-step forming method combined pre-tensioned basalt fiber-reinforced polymer (BFRP) bars with bamboo through compression molding. The BFRP-bamboo composite beams exhibited better flexural performance. Wdowiak-Postulak and associates (Wdowiak-Postulak 2023; Wdowiak-Postulak et al. 2023, 2024) conducted four-point bending tests on timber beams enhanced by different post-tensioned bars, including steel, glass, and basalt bars. The results indicated that prestressed steel bars provided the most significant improvements in ultimate strength and stiffness.

In terms of FRP sheets or plates, researchers mainly have adopted three methods to apply prestress in timber/bamboo structures (Halicka and Slosarz 2021, 2022). The first method involved adhering FRP sheets to the bottom surface after cambering the beam. Triantafillou and Deskovic (1992) first established the method of FRP-sheet reinforcement for timber/bamboo structures. CFRP sheets were adhered to the tension surface of the timber beam. Wang et al. (2016) also conducted similar experiments, proposing that this method was suitable for reinforcing traditional timber structure beams. Borri et al. (2005) adhered CFRP sheets to the bottom surface of timber beams after the pre-bending process with three-point loading. It was observed that three layers of CFRP sheets could enhance the flexural capacity by 60.3% compared with unreinforced beams.

In the second method, the strips were pre-tensioned and then adhered to the bottom surface of the beam with adhesive. Dolan et al. (2001, 2016) used hydraulic jacks to introduce kevlar fiber-reinforced polymer (KFRP) fabric and GFRP rods to reinforce GLT beams. It was observed that the stiffness increased by 25% and 70%, and the ultimate flexural strength increased by 25% and 110%, respectively. İşleyen et al. (2021, 2023) conducted analyses of pre-tensioned CFRP-reinforced timber beams, finding that the flexural performance of damaged timber beams could be restored to an undamaged state after reinforcement. Halicka and Slosarz (2021, 2022) used hydraulic actuators to tension FRP sheets, which were then adhered to the surface of timber beams. The advantages of pre-tensioned CFRP strips lie in reducing beam deflection and shifting the failure mode from flexural failure to delamination failure.

Step-wise pre-stressing was the third method. This method was first proposed by Stöcklin and Meier (2003) and was initially applied to prestressing concrete structures at EMPA (Swiss Federal Laboratories for Material Testing and Research). In this method, a pre-tensioned section was bonded in the middle of the FRP strip at mid-span first. An electric heating system was used to accelerate the curing of the adhesive. After the middle part of the FRP strips was firmly bonded to the mid-span of the beam, the prestress value was reduced and the FRP was adhered to both sides of the beam gradually. These steps were repeated multiple times until the entire strip was bonded. Brunner and Schnüriger (2005) used the step-wise pre-stressing method to introduce prestress to FRP plates reinforcing timber beams. Epoxy adhesive is applied to one side of the FRP plate, and heating activates the adhesive in that area, attaching the FRP to the bottom mid-span of the beam. Starting from the mid-span, the process gradually moves towards the supports while reducing the prestress. Dagher and Altimore (2005) suggested that the load-bearing capacity of prestressed GFRP reinforced timber beams using the EPMA method increased by about 95% compared with non-reinforced beams.

Prestress Loss

Prestress loss is inevitable in prestressed flexural members. The loss can be classified into immediate losses and long-term losses based on the time the losses occurred. Immediate loss includes friction loss, anchorage loss, and sequential tensioning loss in post-tensioning (He et al. 2022). Long-term losses include creep, prestress relaxation, temperature differential loss, and loss due to elastic deformation, all of which develop over time (Davies and Fragiacomo 2011; Riccadonna et al. 2020).

Scholars have described the changes in prestress over time in timber/bamboo beams. Quenneville and Vandalen (1994a,b) proposed rheological models and equations for prestress relaxation in timber beams under different environmental humidity conditions. Fragiacomo and associates (Fragiacomo and Davies 2011; Fragiacomo et al. 2011; Davies and Fragiacomo 2011) derived the prestress loss of LVL timber beams under long-term loading. Palermo et al. (2011) extended this model to other cable profiles such as catenary or parabolic and multi-span beams, providing a unified design procedure. Chen and Feng (2013) derived and validated the initial prestress formula for pre-tensioned FRP-strengthened timber beams with 3 CFRP-reinforced timber beams. Lv et al. (2019a,b) studied a novel BFRP-reinforced bamboo beam, categorizing prestress loss into 4 parts and proposing a method for effective prestress calculation. Based on experimental results, Fojtík et al. (2023) established an effective prestress expression for prestressed glued laminated timber beams. The prestress loss calculation methods summarized in each study are depicted in Table 1.

Table 1. Prestress Loss Calculation Model

Zheng et al. (2019) systematically proposed the calculation method for the prestress loss in prestressed CFRP plate-strengthened GLT beams. The prestress loss was divided into two parts. The first batch of prestress loss included cushion deformation and timber elastic deformation loss, while the second batch of losses included CFRP prestress relaxation, seasonal temperature difference, and timber creep loss. Based on the assumption of plane cross-section and the relationship between force balance and deformation coordination, the formula for prestress loss in FRP-reinforced glued laminated beams was established, as exhibited in Table. 2.

Researchers have also conducted controlled evaluation of prestress loss. Brunner and Schnüriger (2005) employed gradient anchorage technology, using an electronic control device to bond the prestressed laminate to the timber beam, addressing the issue of delamination. Dagher and Altimore (2005) developed a novel device for applying prestress in GFRP plates, with measured prestress loss in GFRP after 12 days being less than 2% of the original initial stress. Giongo et al. (2013) utilized self-tapping screws and found that prestress loss was reduced probably because the screws transmitted the load deeper into beams, reducing compressive stress at the end of beams. Guo et al. (2018, 2021, 2022) increased the number of prestressed steel strands used for external prestressing from 2 to 4 and found a significant reduction in prestress loss. However, when the number increased to 6, there was no change observed in prestress loss. Zuo et al. (2016) conducted a 45-day long-term loading test on 10 prestressed GLT beams. The study revealed that as the quantity of steel reinforcement increased, there was a corresponding increase in total prestress value and total stress loss, while mid-span long-term deflection declined.

Table 2. Zheng’s (Zheng et al. 2019) Prestress Loss Calculation Model

In summary, pre-arching, as an early commonly used prestressing method, is characterized by its simple principle. Early pre-arching timber/bamboo beams relied on external loads and movable supports. Recently, researchers are continuing to explore pre-arching methods through moisture-dependent swelling nature or bending curvature characteristics of the timber without external equipment. Compared to the pre-arching timber/bamboo beams, additional prestressed components can significantly enhance the ultimate load-bearing capacity and crack resistance, with more precise control of prestress accuracy and less prestress loss under long-term loads, meeting the requirements of industrial producing requirements. Additional prestressed components include bars, sheets, and plates, primarily made of steel and FRP. Prestressed steel bars can significantly enhance the flexural capacity of timber /bamboo beams, while steel plates exhibit superior performance in reducing crack propagation. In addition to steel prestressed components, FRP sheets and bars are also widely used in the reinforcement of bending-resistant timber/bamboo structures due to their excellent strength-to-weight ratio and corrosion resistance. Additionally, the performance of adhesives significantly affects the timber/bamboo beams with prestressed sheets. The properties of the binder, bonding methods, and the contact mechanism between FRP bars and timber beams need further investigation. Furthermore, prestress loss is an unavoidable issue in prestressed structures. The components of prestress loss and the methods for calculating prestress in timber/bamboo beams have no unified standards yet, and measures to reduce prestress loss require further innovation and exploration.

PRESTRESSED TIMBER/BAMBOO COMPOSITE COLUMNS

Unlike bending members, prestress in compressed components such as columns often appears in the form of lateral constraints, where the prestress can restrict lateral expansion, reduce column buckling, and enhance the column’s compressive load-bearing capacity.

Traditional timber columns have defects of relatively low load-bearing capacity, large cross-sectional area, susceptibility to erosion, and vulnerability to insect damage. Peripheral constraint materials including steel and FRP, etc. are commonly adopted for the reinforcement of timber columns (Krishnan 2020; Xu et al. 2023). The reinforcement measurement could delay the local buckling of steel tubes and reduce the outward expansion of the timber (Wang et al. 2024). However, simple wrapping reinforcement offers limited mechanical performance enhancements for timber columns, with disadvantages such as low combination efficiency. Therefore, prestress is introduced into composite columns, applying initial lateral stress to the core timber through external wrapping materials. The reinforcement method using prestress places the core timber in a triaxial compression state upon encountering external loads, effectively limiting lateral deformation of the timber and avoiding stress hysteresis in steel (Krishnan 2020).

Fig. 7. Prestressed timber composite columns

Yang et al. (2018) utilized prestressed steel strips with different layers and spacing to reinforce cracked timber columns. The results demonstrated that the ductility and energy dissipation performance capacity of the cracked timber columns were enhanced, but steel strips had no significant impact on the stiffness. Li et al. (2019) and Wang et al. (2022) proposed a novel prestressed thin-walled steel tube confined timber column, where constraints were applied by a thin-walled steel tube. Bolt holes were punched into the steel strip, and the tightening force of bolts was the main measure to apply circumferential prestress, as shown in Fig. 7. Additionally, Li et al. (2019) also proposed a calculation model for the ultimate strength of the new prestressed steel-timber composite column, as indicated in Eq. 1,

where Fwc represents the ultimate strength of composite columns confined by prestressed steel tube, Fw0 represents the ultimate strength of unconfined timber columns; Fil represents the initial lateral confining stress induced in the core timber column by the initial steel strain, and Fel represents the effective lateral confining stress induced in the core timber column by steel tube.

Qiu et al. (2021) developed a numerical model for prestressed thin-walled steel confined square timber columns. The numerical analysis results indicated that excessive prestress in composite columns could lead to yielding in parts of the steel, thus weakening the effect of active confinement and resulting in a lower ultimate load capacity. Wang et al. 2022) wrapped a CFRP sheet around the exterior of prestressed steel-timber columns. It was discovered that the addition of CFRP sheets significantly improved the ductility and axial load-bearing capacity of columns.

LATERAL RESISTING STRUCTURAL SYSTEMS

In terms of lateral resistance structures, prestress is also applied to the seismic performance enhancement of timber/bamboo structures (Nguyen et al. 2018; Smith et al. 2016). American and Japanese scholars have proposed resilient cities as the main direction for future research. Self-centering earthquake-resistant structures, as a type of resilient structures, have become one of the research hotspots in recent years (Froozanfar et al. 2024). The self-centering seismic system is a novel structural system that combines prestress and energy-dissipating technologies to realize seismic resilience (Amer 2023). Moreover, the self-centering design concept is also extended to the timber/bamboo structural systems, including self-centering timber/bamboo frame structures (Di Cesare et al. 2018; Iqbal and Popovski 2017; Shu et al. 2019) and self-centering timber/bamboo shear walls, etc. (Chen et al. 2024; Fitzgerald et al. 2020; Sun, et al. 2020). The specific implementation methods are described as follows.

Self-centering Frame Structures

The ductile design of traditional frame structures with strong columns and weak beams utilizes the plastic deformation of structural components to dissipate seismic energy (Nie et al. 2020; Park 1986). This kind of design results in a severe post-earthquake loss (Paulay 1986; Wongpakdee and Leelataviwat 2017). Consequently, prestress has been employed to connect beam-column joints in frame structures, effectively addressing this issue. Palermo et al. (2005), based on Priestley’s theory (Priestley and Calvi 1991), which pioneered the low-damage design of reinforced concrete structures, proposed a multi-LVL seismic-resistant frame system using post-tensioned tendons connections called Prestressed-Laminated (Pres-lam) systems. This method adopted unbonded prestressed tendons to connect the structural components. Internal energy steel bars were adopted to dissipate energy, thus resulting in a special ‘flag-shaped’ self-centering dissipative hysteresis loop as shown in Fig. 8.

Newcombe et al. (2008) proposed a novel seismic resisting system for multi-story timber buildings, integrating improved ductile steel connections based on the post-tensioning method and rocking timber frames. The connections between beams and columns involved LVL, unbonded post-tensioned tendons, and energy dissipaters. Iqbal et al. (2016) conducted full-scale tests on Newcombe’s system, using both steel dissipaters and unbonded post-tensioning mild steel reinforcement. This hybrid system offered significantly higher energy dissipation compared with schemes relying solely on steel bars. Iqbal et al. (2018) also studied the mechanical behavior of post-tensioning connections with specific energy dampers, achieving near-zero residual deformation. Sarti et al. (2016) proposed a CWC (column-wall-column) rocking column-shear wall hybrid system, where vertical prestressed steel bars were tensioned within the timber walls, and U-shaped steel plates served as additional overturning moment resistance and energy dissipaters. Wei and associates (Wei et al. 2024; Wu et al. 2014) conducted experiments on rigid timber wall panels equipped with slip-friction connectors, which imparted ductility and elastoplastic characteristics to brittle structures.

Fig. 8. Palermo’s model (Palermo et al. 2005; CC0 1.0 Universal)

 

Di Cersare et al. (2017, 2018, 2020) conducted dynamic tests on a three-story post-tensioned timber frame structure equipped with an energy-dissipating brace system. The elastic seismic performance was enhanced by coupling the post-tensioned frame with the energy-dissipating braces. Smith et al. (2014, 2016) conducted experimental research on inclined steel plate post-tensioned GLT connections and observed strong self-centering and energy dissipation capability. Wanninger and Frangi (2014), Wanninger et al. (2015) and Granello et al. (2018, 2019) conducted a series of pushover tests on post-tensioned timber structural frames. The results showed that these connections presented low damage levels in tests. Li et al. (2020) compared the performance of hybrid post-tensioned GLT connections with tenon connections and concluded that post-tensioned timber connections exhibited smaller residual deformations.

Self-centering Shear Walls

Although traditional shear walls using nailed or bolted connections have been shown to have high strength and stiffness, their deformation capacity is limited in earthquakes (Aloisio et al. 2023a; Brown et al. 2022). The shear walls exhibited brittle characteristics in an earthquake, leading to stiffness degradation, substantial base shearing, severe connection damage, etc. (Li et al. 2018; Hasani and Ryan 2022). Consequently, scholars have investigated self-centering rocking or shear wall systems using post-tensioned prestressed connections (Miliziano et al. 2020; Piri and Massumi 2022; Brown et al. 2023). This structure employed vertical prestressing tendons to pre-compress the walls to the foundation, supplemented with small energy-dissipating components such as U-shaped flexural plates (UFP) or post-tensioned (PT) tendons (Sun et al. 2020; Wilson et al. 2020), as shown in Fig. 9. Under seismic actions, gap openings were present at the bottom of the walls, thus effectively controlling structural damage and reducing residual displacements (Aloisio et al. 2023c; Brown et al. 2023). In addition, the energy-dissipating components enhanced the energy dissipation capacity of the structure, further mitigating the seismic response (Cui et al. 2020; Piri and Massumi 2022).

Fig. 9. UFP and PT

Iqbal et al. (2015) proposed a new form of self-centering rocking wall coupled with PT tendons and UFPs as energy dissipation devices. UFP dissipaters exhibited stable energy dissipation characteristics and an ideal flag-shaped hysteresis behavior was achieved by combining UFPs with PT tendons. Ganey et al. (2017) described experiments conducted to develop a resilient wall system that combined cross-laminated timber (CLT) panels with vertical PT tendons to provide post-earthquake recovery.

He and associates (Chen et al. 2021; He et al. 2022; Li et al. 2023) introduced a new type of self-centering steel-timber hybrid shear wall system (SC-STHSW), which employed post-tensioned tendons for the connection of frame beam-column joints, with slip friction dampers serving as connectors between the frame and the wall. Low-cycle quasi-static tests on this system revealed that the SC-STHSW system exhibited unique flag-shaped hysteresis characteristics. The prestressed connection method effectively controlled residual deformations of the structure, and the additional friction dampers enhanced the energy dissipation capacity. Lu et al. (2022, 2024) proposed a self-centering CLB (cross-laminated bamboo) rocking wall structural system using two kinds of friction dampers: traditional friction dampers and novel bending-friction coupled dampers (BFCD). The results obtained from quasi-static tests and finite element analyses indicated that the BFCD provided higher stiffness and energy dissipation capacity under a high drift ratio.

Traditional frame structures and shear wall structures are two different structural forms. A lateral force-resisting system composed of beams and columns is used in frame structures to withstand seismic actions, while shear wall structures resist seismic actions through their own bending and shear stiffness. Compared to frame structures, shear wall systems are more suitable for high-rise buildings, with a maximum applicable height of up to 140 meters in seismic design.

Based on traditional frame systems, self-centering timber frame structures originated from Palermo’s (2005) research on the low-damage prestressed laminated (Pres-Lam) system. Unbonded post-tensioned tendons connect the timber structural members, forming connections that resist seismic forces and dissipate energy, thereby overcoming the stiffness degradation and connection damage issues faced by traditional frames during earthquakes. Unlike the self-centering timber frame mechanism that uses press at beam-column joints, the self-centering timber shear wall system uses vertical prestressing tendons to press the wall to the foundation, supplemented by small energy-dissipating components such as UFPs. This approach reduces residual displacement and enhances energy dissipation capacity.

PRESTRESSED LARGE-SPAN TIMBER STRUCTURAL SYSTEMS

In large-span structures, buckling is a crucial factor affecting the strength and stability of the structure as spacing increases (Fraternali and Motta 2023). Consequently, components of large-span structures should be designed to be axially loaded to ensure performance stability (Crocetti 2016; Dietsch and Winter 2018). Moreover, due to the large number of components in large-span structures, there are high demands on connection performance. Therefore, existing studies have applied prestress to large-span structures through the string approach. This structural system originated from the concept of tensioning the beam via chords through rods (Saitoh 1998; Saitoh and Okada 1999). The short rods were placed under the beam, applying prestress to the beam via cables, as shown in Fig. 10. The compressive force on the rods created a counter moment and reverse deflection in the upper chord structure, thus reducing the maximum moment and final deflection under external loads, and improving the structural stress distribution (Nie and Li 2012). The string method was also applied in the timber/bamboo large-span structures.

Fig. 10. Types of string structures

Plane String Structures

The concept of plane string structure was first used in the 138.7-meter-long Royal Albert Double-Span Railway Bridge in 1859 (Norrie 1956), as shown in Fig. 11. Masao Saito defined the beam chord structure at the IASS Symposium as a self-balancing system composed of compressive and tensile components connected by vertical rods. Plane string timber/bamboo structures have also been investigated (Zhao et al. 2024). Current research has employed analytical methods, finite element analysis, and model testing to study the performance of plane timber/bamboo string structures, including the number of vertical rods, initial geometric defects, and material elastoplastic (Lee et al. 2023).

Fig. 11. Royal Albert Double-span Railway Bridge (https://en.wikipedia.org/wiki/Royal_Albert_Bridge#cite_note-3)

Zhang et al. (2014) conducted compressive tests on the glued string beams and concluded that increasing the arch-span ratio or sag-span ratio could enhance the load-bearing capacity. Guo et al. (2019) employed experimental and numerical research to explore factors affecting the performance of string truss GLT beams, finding that the stronger the compressive performance increased with the number of prestressing steel wires and the magnitude of the prestress. String truss GLT beams exhibited a ductile failure mode. Bending tests were conducted by Sun et al. (2016) on plane string beams with additional prestressed steel strands on the lower chord. The results showed that the brittle failure mode in ordinary beams was transformed into a plastic failure mode, with their ultimate load-bearing capacity and stiffness inversely proportional to the span ratio. Zhao et al. (2023) conducted five-point bending tests on large-span glulam string beams. The results indicated that as the diameter increased, the failure region shifted from the lower steel cable to the upper composite beam.

Fig. 12. Horinouchi Town Gymnasium in Japan (https://data.shinkenchiku.online/en/projects/articles/SK_1996_12_240-0)

Plane string structures are suitable for complex architectural forms, with broad application prospects. The Horiuchi Town Gymnasium in Japan (Saitoh 1998), with a 38 m span, exemplified a timber plane string structure using composite truss beams, as exhibited in Fig. 12. Situated in a snowy region of Japan, the design considered a snow depth of up to 3.5 m. Ingeniously, diagonal rods and columns were added to the string beams; thus, the rigidity of the string components was increased during heavy snow-loading conditions.

Spatial String Structures

Spatial string structures are formed from plane string configurations arranged in specific spatial layouts. Common types include bidirectional, multidirectional, and radial spatial string structures (Yifeng and Jian 2011). Due to the complex forces involved, modeling experiments on spatial string structures are challenging. Consequently, scholars often utilize numerical analysis methods for research (Cantcheff 2011).

Rumlová and Fojtík (2015) used finite element analysis to study the strain changes at critical joints in spatial timber roof supports. Sejkot et al. (2020) examined the lateral stability of single and bidirectional timber string roof structures through numerical simulation and geometric nonlinear analysis. The results revealed that lateral torsional buckling of the top chords adversely affected the load-bearing capacity against out-of-plane buckling. Ching and Carstensen (2022) developed a topology optimization algorithm for steel-timber hybrid spatial string structures, aimed at reducing carbon emissions.

The Izumo Dome in Japan, completed in 1992, was a typical application of timber spatial string structures, featuring a spatial arch string structure with a diameter of 140 m and height of 49 m (Tsubota et al. 1993). Composed of radial wooden arches and a lower cable system, the structure was covered with an external membrane, as illustrated in Fig. 13. The dome was entirely assembled on the ground, elevated and heightened through a central temporary support structure, lifting the dome into place.

Fig. 13. The Izumo Dome in Japan (https://en.wikipedia.org/wiki/Izumo_Dome)

Plane string structures primarily extend within a two-dimensional plane and are commonly found in roofs and bridges, including forms such as beam string structures, arch string structures, and cable-arch string structures. Spatial string structures are composed of plane string structures arranged in specific spatial configurations, including bidirectional string structures, multidirectional string structures, and radial string structures, which are more suitable for large-span structural roofs. Research on modern timber/bamboo string structures is still relatively limited, requiring further study on their load-bearing mechanisms and seismic performance to promote their engineering applications.

BIBLIOMETRIC ANALYSIS ON PRESTRESSED TIMBER/BAMBOO STRUCTURES

Recent research hotspots were identified in this work through statistical analysis. Knowledge maps depicted innovative developments and forecasted future directions (Börner et al. 2003). The primary research corpus was sourced from the Web of Science database, with data mining facilitated by CiteSpace. Keyword trend analysis, as shown in Fig. 15, elucidated development hotspots, revealing a shift in research focus towards structural seismic resilience over the past two decades. Efforts have concentrated on understanding the mechanical behavior and performance characteristics of individual components, laying theoretical foundations for practical engineering applications.

Fig. 14. Keywords analysis

However, translating research findings into practical engineering applications remains limited with unresolved issues:

(1) Efficient timber/bamboo component reinforcement schemes

Currently, combining steel and FRP can mitigate the shortcomings of timber/bamboo materials. Steel is prone to corrosion and is heavy, while timber/bamboo materials are hygroscopic. Timber/bamboo beams reinforced by FRP may face problems including reduced bonding or delamination, aging, humidity, temperature fluctuations, etc. Consequently, the development and research in novel strong, lightweight, durable, and economical materials for reinforcing timber/bamboo components and structures are needed.

(2) Evaluation and control of prestress loss

Timber/bamboo structures are sensitive to environmental humidity and temperature changes. Creep can easily cause prestress loss, affecting long-term performance and threatening durability. Research on prestress loss could help predict and control the effectiveness of prestress more accurately in practical design. Currently, there is no unified standard for calculating prestress loss in prestressed timber/bamboo components and connections. Therefore, further research is needed on the long-term performance considering prestress loss.

(3) Novel prestressed timber/bamboo structural systems

Currently, there is no widely applied form of prestressed timber/bamboo structures. Prefabrication of timber/bamboo structures is a key focus of future research in structural engineering. By reasonably combining prestressed components or additional parts, modular units can be achieved, promoting prefabricated design and production. There is an urgent need for novel structures that can be rapidly assembled and possess stable seismic performance. This will effectively ensure construction safety in earthquake areas and reduce the damage caused by seismic disasters.

CONCLUDING REMARKS

Since the 1950s, extensive research has been conducted by scholars on prestressed timber/bamboo structures, initially focusing on the mechanical performance of individual components post-tensioning, gradually shifting to the overall structural performance. This paper has provided an overview of the historical development and latest advancements in prestressed timber/bamboo structures from the component, connection, and structural levels, as shown in Fig. 15. This study utilized bibliometric analysis to summarize existing research, identifying the issues remaining to be addressed and future development directions in the field of prestressed timber/bamboo structures. The main research conclusions are as follows:

(1) To address the shortcomings of low stiffness and susceptibility to deformation in timber/bamboo flexure components, external load pre-cambering and additional prestressed components are used to reinforce timber/bamboo flexural components. The results indicate that when retrofitted with prestress, timber/bamboo flexural components present improved ultimate bearing capacity, ductility, and stiffness. Meanwhile, prestress loss in prestressed reinforced bending components is inevitable. Further research on the long-term performance of prestressed timber/bamboo structures considering prestress loss is necessary.

(2) Prestress in timber/bamboo columns often appears in the form of lateral confinement. Thin-walled steel tubes are commonly used to constrain the timber columns. Circumferential prestress is applied to the thin-walled steel through bolt-tightening force, placing the core timber column in a triaxial compression state when subjected to external loads. Prestressed steel-timber composite columns can enhance the ultimate compressive bearing capacity of the columns, improving ductility and energy dissipation characteristics.

(3) Self-centering lateral resistance timber/bamboo structures can enhance seismic performance through prestress technology. Self-centering timber/bamboo frames and shear wall systems have continuously developed over the past two decades. The combination of prestressed connections and additional energy-dissipating components can effectively control seismic damage, achieving excellent flag-shaped hysteretic performance. However, such structures have not yet been widely applied. The actual seismic response and anti-collapse performance need further investigation.

(4) Existing research applies prestress to timber/bamboo large-span structural systems through the string method, changing their failure mode to ductile failure. Timber/bamboo string structures are favored for their elegant and smooth configuration and spatial sense, with practical applications such as the Izumo Dome in Japan. To promote the development of such structures, further research is needed from the perspectives of numerical simulation, theoretical study, and model testing, especially considering the long-term performance of structures with varying prestress.

Fig. 15. Overview of the history and recent advances in timber/bamboo structures

Despite significant progress in various prestressed timber/bamboo structures, practical engineering applications remain limited. In addition to technical considerations, the economic implementation of prestressing technology requires comprehensive life-cycle cost assessments. Additionally, it is necessary to translate research achievements and existing engineering experience into design codes and standards. Advances in materials science, structural testing, and computational technology will further promote the development of prestressed timber/bamboo systems, contributing to greener and more sustainable urban construction.

ACKNOWLEDGEMENTS

The authors would like to extend their sincere gratitude to the National Natural Science Foundation of China (52378222).

List of SYMBOLS

REFERENCE CITED

Abdulhameed, A. A., Hason, M. M., Sharba, A. A. K., Hanoon, A. N., Amran, M., Magbool, H. M., and Gamil, Y. (2023). “Experimental and environmental investigations of the impacts of wood sawdust on the performance of reinforced concrete composite beams,” Case Studies in Construction Materials 19, article e02550. DOI: 10.1016/j.cscm.2023.e02550

Achintha, M., and Balan, B. (2019). “Mechanical prestressing of annealed glass beams using pretensioned GFRP: Characterisation and potentiality,” Structures 20, 11-19. DOI: 10.1016/j.istruc.2019.02.017

Ahmad, Y. (2010). Bending Behavior of Timber Beams Strengthened Using Fiber Reinforced Polymer Bars and Plates, Doctoral dissertation, Universiti Teknologi Malaysia.

Akl, A., Saiid Saiidi, M., and Vosooghi, A. (2017). “Deflection of in-span hinges in prestressed concrete box girder bridges during construction,” Engineering Structures 131, 293-310. DOI: 10.1016/j.engstruct.2016.11.003

Al-Emrani, M., and Kliger, R. (2006). “Analysis of interfacial shear stresses in beams strengthened with bonded prestressed laminates,” Composites Part B: Engineering, 37(4), 265-272. DOI: 10.1016/j.compositesb.2006.01.004

Al-Saadi, N. T. K., Mohammed, A., and Al-Mahaidi, R. (2017). “Assessment of residual strength of concrete girders rehabilitated using NSM CFRP with cementitious adhesive made with graphene oxide after exposure to fatigue loading,” Construction and Building Materials 153, 402-422. DOI: 10.1016/j.conbuildmat.2017.07.121

Aloisio, A., Boggian, F., Sævareid, H. Ø., Bjørkedal, J., and Tomasi, R. (2023a). “Analysis and enhancement of the new Eurocode 5 formulations for the lateral elastic deformation of LTF and CLT walls,” Structures 47, 1940-1956. DOI: 10.1016/j.istruc.2022.11.129

Aloisio, A., Pasca, D. P., De Santis, Y., Hillberger, T., Giordano, P. F., Rosso, M. M., Tomasi, R., Limongelli, M. P., and Bedon, C. (2023b). “Vibration issues in timber structures: A state-of-the-art review,” Journal of Building Engineering 76, article 107098. DOI: 10.1016/j.jobe.2023.107098

Aloisio, A., Rosso, M. M., Huang, D., Iqbal, A., Fragiacomo, M., and Pei, S. (2023c). “Nonlinear analytical modeling of mass-timber buildings with post-tensioned rocking walls,” Bulletin of Earthquake Engineering 21(1), 473-502. DOI: 10.1007/s10518-022-01553-2

Amer, A. M. (2023). Multidirectional Experimental Performance of a Seismically Resilient Self-Centering Cross-Laminated Timber Shear Wall System. (Order No. 30487437). [Ph.D., Lehigh University]. Available from ProQuest Dissertations & Theses Global; ProQuest Dissertations & Theses Global A&I: The Sciences and Engineering Collection. (2817945138). https://www.proquest.com/dissertations-theses/multidirectional-experimental-performance/docview/2817945138/se-2

Anshari, B. (2015). “Analytical approach to predict pre–camber deflection of the pre-stressed glulam beams,” Civil Engineering Dimension 17(1), 44-49. DOI: 10.9744/ced.17.1.44-49

Anshari, B., and Guan, Z. (2017). “FE modelling of optimization on strengthening glulam timber beams by using compressed wood blocks,” Procedia Engineering 171, 857-864. DOI: 10.1016/j.proeng.2017.01.379

Anshari, B., and Guan, Z. W. (2014). “Numerical modelling of the initial stress and upward deflection of glulam beams pre-stresseed by compressed wood,” Applied Mechanics and Materials 493, 408-413. DOI: 10.4028/www.scientific.net/AMM.493.408

Anshari, B., Guan, Z. W., Kitamori, A., Jung, K., and Komatsu, K. (2012). “Structural behaviour of glued laminated timber beams pre-stressed by compressed wood,” Construction and Building Materials 29, 24-32. DOI: 10.1016/j.conbuildmat.2011.10.002

Arafat, M. E., and Imam, F. (2022). “Suitability of recycled materials as a composite sleeper: A scoping review,” Materials Today: Proceedings 65, 1599-1607. DOI: 10.1016/j.matpr.2022.04.599

Ardalany, M., Deam, B., Fragiacomo, M., and Crews, K. (2011). “Tension perpendicular to grain strength of wood, laminated veneer lumber (LVL), and cross-banded LVL (LVL-C),” in: Incorporating Sustainable Practice in Mechanics of Structures and Materials-Proceedings of the 21st Australian Conference on the Mechanics of Structures and Materials. DOI: 10.1201/b10571-162

Banks, C. H. (1972). “Modern trends and new timber products in the timber industry,” South African Forestry Journal 82(1), 2-7. DOI: 10.1080/00382167.1972.9629272

Bai, Y., Zhang, J., and Zhang, X. (2024). “Scaling study on the fire resistance of cross-laminated timber floors,” Journal of Building Engineering 85, article 108679. DOI: 10.1016/j.jobe.2024.108679

Bartlett, A. I., Hadden, R. M., and Bisby, L. A. (2019). “A review of factors affecting the burning behaviour of wood for application to tall timber construction,” Fire Technology 55, 1-49. DOI: 10.1007/s10694-018-0787-y

Bedriñana, L. A., Tani, M., and Nishiyama, M. (2021). “Deformation and cyclic buckling capacity of external replaceable hysteretic dampers for unbonded post-tensioned precast concrete walls,” Engineering Structures 235, article 112045. DOI: 10.1016/j.engstruct.2021.112045

Bohannan, B. (1962). “Prestressing wood members,” 12(12), 596-602.

Börner, K., Chen, C., and Boyack, K. W. (2003). “Visualizing knowledge domains,” Annual Review of Information Science and Technology 37(1), 179-255. DOI: 10.1002/aris.1440370106

Borri, A., Corradi, M., and Grazini, A. (2005). “A method for flexural reinforcement of old wood beams with CFRP materials,” Composites Part B: Engineering 36(2), 143-153. DOI: 10.1016/j.compositesb.2004.04.013

Boyd, J. (1950). “Tree growth stresses. II. The development of shakes and other visual failures in timber,” Australian Journal of Applied Science 1(3), 296-312. DOI: 10.1071/BI9500270

Breveglieri, M., and Czaderski, C. (2021). “RC slabs strengthened with externally bonded CFRP strips under long-term environmental exposure and sustained loading. Part 2: Laboratory experiments,” Composites Part C: Open Access 6, article 100210. DOI: 10.1016/j.jcomc.2021.100210

Brown, J. R., Li, M., Palermo, A., Pampanin, S., and Sarti, F. (2023). “Analytical modeling of posttensioned C-shaped CLT core walls,” Journal of Structural Engineering 149(3), article 04023009. DOI: 10.1061/JSENDH.STENG-11455

Brown, J. R., Li, M., Palermo, A., Pampanin, S., Sarti, F., and Nokes, R. (2022). “Experimental testing and analytical modelling of single and double post-tensioned CLT shear walls,” Engineering Structures 256, article 114065. DOI: 10.1016/j.engstruct.2022.114065

Brunner, M., and Schnüriger, M. (2005). “Timber beams strengthened by attaching prestressed carbon FRP laminates with a gradiented anchoring device,” in: Proceedings of the International Symposium on Bond Behaviour of FRP in Structures (BBFS 2005).

Bu, Z.-Y., and Wu, W.-Y. (2018). “Inter shear transfer of unbonded prestressing precast segmental bridge column dry joints,” Engineering Structures 154, 52-65. DOI: 10.1016/j.engstruct.2017.10.048

Caldenby, C. (2018). “Construction history in Scandinavia,” Histoire des Techniques (Tome I), 373-385.

Caniato, M., Bettarello, F., Ferluga, A., Marsich, L., Schmid, C., and Fausti, P. (2017). Acoustic of lightweight timber buildings: A review. Renewable and Sustainable Energy Reviews 80, 585-596. DOI: 10.1016/j.rser.2017.05.110

Canning, L., and Luke, S. (2008). “Flexural strengthening application of fibre-reinforced polymer (FRP) plates,” in: Strengthening and Rehabilitation of Civil Infrastructures Using Fibre-Reinforced Polymer (FRP) Composites, L. C. Hollaway and J. G. Teng (eds.), Woodhead Publishing, Ch. 10, pp. 267-291. DOI: 10.1533/9781845694890.267

Cantcheff, M. B. (2011). “Spacetime geometry as statistic ensemble of strings.” arXiv preprint arXiv:1105.3658.

Capozucca, R. (1998). “Bond stress system of composite concrete – timber beams,” Materials and Structures 31(213), 634-640. DOI: 10.1007/BF02480615

Chen, F., Li, M., and Li, Z. (2024). “Self-centering mass timber structures: A review on recent research progress,” Engineering Structures 303, article 117474. DOI: 10.1016/j.engstruct.2024.117474

Chen, F., Li, Z., He, M., Wang, Y., Shu, Z., and He, G. (2021). “Seismic performance of self-centering steel-timber hybrid shear wall structures,” Journal of Building Engineering 43, article 102530. DOI: 10.1016/j.jobe.2021.102530

Chen, H. L. R., He, Y. D., and GangaRao, H. V. (1998). “Measurement of prestress force in the rods of stressed timber bridges using stress waves,” Materials Evaluation 56(8), 977-981.

Chen, J., and Feng, S. (2013). “Study on the maximum initial prestression of prestressed FRP reinforcement in wood beams,” Journal of Lanzhou Jiaotong University 32(1), 49-52.

Chen, S., Wei, Y., Ding, M., Zhao, K., and Zheng, K. (2022). “Combinatorial design and flexural behavior of laminated bamboo–timber composite beams,” Thin-Walled Structures 181, article 109993. DOI: 10.1016/j.tws.2022.109993

Cheng, X., Wei, Y., Xu, Y., Li, G., and Wang, X. (2018). “Experimental study on mechanical properties of bamboo beam reinforced with prestressed FRP bars,” Building Structure 48(10), 108-113.

Ching, E., and Carstensen, J. V. (2022). “Truss topology optimization of timber–steel structures for reduced embodied carbon design,” Engineering Structures 252, article 113540. DOI: 10.1016/j.engstruct.2021.113540

Christoforo, A. L., Gomes, A. F. F., Arroyo, F. N., Mascarenhas, F. J. R., Santos, H. F. d., Topolniak, L., and Akasaki, J. L. (2022). “Reinforcement of Timber beams with steel bars: Parametric analysis using the finite element method,” Buildings 12(7), 1036. DOI: 10.3390/buildings12071036

Colombi, P., and Fava, G. (2015). “Experimental study on the fatigue behaviour of cracked steel beams repaired with CFRP plates,” Engineering Fracture Mechanics, 145, 128-142. DOI: 10.1016/j.engfracmech.2015.04.009

Crocetti, R. (2016, March). “Large-span timber structures,” in: Proceedings of the World Congress on Civil, Structural, and Environmental Engineering. DOI: 10.11159/icsenm16.124

Cui, Y., Chen, F., Li, Z., and Qian, X. (2020). “Self-centering steel-timber hybrid shear wall: Experimental test and parametric analysis,” Materials 13(11), article 2518. DOI: 10.3390/ma13112518

Cui, Z., Huang, D., Huang, Z., et. al. (2022). “Experimental investigation and calculation method for the bearing capability of bolt steel-to-laminated bamboo connections under the coupling of bending moment and shear force,” Journal of Building Engineering 57, anrticle 105126. DOI: 10.1016/j.jobe.2022.105126

Cui, Z., Xu, M., Li, A., Tu, L., Zhu, J., and Shen, Y. (2023). “Fire resistance evaluation of laminated bamboo lumber column under eccentric compression,” Engineering Structures 288, article 116226. DOI: 10.1016/j.engstruct.2023.116226

Cui, Z., Xu, M., Shen, Y., et al. (2024). “The impact of temperature variations on the thermal and charring characteristics of laminated bamboo lumber,” European Journal of Wood and Wood Products 82(4), 1159-1169. DOI: 10.1007/s00107-024-02069-z

Cui, Z., Qiu, P., Tu, L., et al. (2024). “Comparative assessment of load-bearing capacities in bolted laminated bamboo lumber connections: A study on diverse reinforcement techniques,” Construction and Building Materials 439, article 137382. DOI: 10.1016/j.conbuildmat.2024.137382.

Custódio, J., and Cabral-Fonseca, S. (2023). “21 – Advanced fiber-reinforced polymer (FRP) composites for the rehabilitation of timber and concrete structures: Assessing strength and durability,” in: Advanced Fiber-Reinforced Polymer(FRP) Composites for Structural Applications, Second Ed., J. Bai (ed.), Woodhead Publishing, Ch. 21, pp. 725-809. DOI: 10.1016/B978-0-12-820346-0.00002-2

D’Aveni, A., and D’Agata, G. (2017). “Post-tensioned timber structures: New perspectives,” Construction and Building Materials 153, 216-224. DOI: 10.1016/j.conbuildmat.2017.07.031

Dagher, H. J., and Altimore, F. M. (2005). “Use of glass-fiber-reinforced polymer tendons for stress-laminating timber bridge decks,” Journal of Bridge Engineering 10(1), 21-27. DOI: 10.1061/(ASCE)1084-0702(2005)10:1(21)

Davies, M., and Fragiacomo, M. (2011). “Long-term behavior of prestressed LVL members. I: Experimental tests,” Journal of Structural Engineering 137(12), 1553-1561. DOI: 10.1061/(ASCE)ST.1943-541X.0000405

De Geetere, L., and Ingelaere, B. (2014). “A new building acoustical concept for lightweight timber frame constructions,” in: INTER-NOISE and NOISE-CON Congress and Conference Proceedings.

De Luca, V., and Marano, C. (2012). “Prestressed glulam timbers reinforced with steel bars,” Construction and Building Materials 30, 206-217. DOI: 10.1016/j.conbuildmat.2011.11.016

Di Cesare, A., Ponzo, F. C., Lamarucciola, N., and Nigro, D. (2020). “Experimental seismic response of a resilient 3-storey post-tensioned timber framed building with dissipative braces,” Bulletin of Earthquake Engineering 18(15), 6825-6848. DOI: 10.1007/s10518-020-00969-y

Di Cesare, A., Ponzo, F. C., Lamarucciola, N., Nigro, D., and Iop. (2018, Februray). “Modelling of post-tensioned timber framed buildings with hysteretic bracing system: Preliminary analysis,” in: International Conference on Construction, Aerotropolis, Aviation and Environmental Engineering (ICCAE). DOI: 10.1088/1755-1315/233/2/022026

Di Cesare, A., Ponzo, F. C., Nigro, D., Pampanin, S., and Smith, T. (2017). “Shaking table testing of post-tensioned timber frame building with passive energy dissipation systems,” Bulletin of Earthquake Engineering 15(10), 4475-4498. DOI: 10.1007/s10518-017-0115-9

Dietsch, P., and Winter, S. (2018). “Structural failure in large-span timber structures: A comprehensive analysis of 230 cases,” Structural Safety 71, 41-46. DOI: 10.1016/j.strusafe.2017.11.004

Dodoo, A., Gustavsson, L., and Sathre, R. (2014). “Lifecycle carbon implications of conventional and low-energy multi-storey timber building systems,” Energy and Buildings 82, 194-210. DOI: 10.1016/j.enbuild.2014.06.034

Dolan, C. W. (2001). “Flexural design of prestressed concrete beams using FRP tendons,” Prestressed Concr. Inst. J. 46(2), 76-87. DOI: 10.15554/pcij.03012001.76.87

Dolan, J. (2016). Collaborative Research: A Resilience-based Seismic Design Methodology for Tall Wood Buildings.

Duwadi, S. R., and Ritter, M. A. (1997). Timber Bridges in the United States, Public Roads, 33. https://cdn-wordpress.webspec.cloud/intrans.iastate.edu/uploads/ 2018/08/duwad95a.pdf

Fitzgerald, D., Miller, T. H., Sinha, A., and Nairn, J. A. (2020). “Cross-laminated timber rocking walls with slip-friction connections,” Engineering Structures 220, article 110973. DOI: 10.1016/j.engstruct.2020.110973

Fojtik, R., Dubovsky, V., Kubincova, L., Stejskalova, K., Machovcakova, E., and Lesnak, M. (2023). “Probabilistic expression of the function of the change in prestressing force of timber elements depending on climatic conditions in situ,” Construction and Building Materials 377, article 130955. DOI: 10.1016/j.conbuildmat.2023.130955

Fragiacomo, M., and Davies, M. (2011). “Long-term behavior of prestressed LVL members. II: Analytical approach,” Journal of Structural Engineering 137(12), 1562-1572. DOI: 10.1061/(ASCE)ST.1943-541X.0000410

Fragiacomo, M., Dujic, B., and Sustersic, I. (2011). “Elastic and ductile design of multi-storey crosslam massive wooden buildings under seismic actions,” Engineering Structures 33(11), 3043-3053. DOI: 10.1016/j.engstruct.2011.05.020

Fraternali, F., and Motta, J. d. C. (2023). “Mechanics of superelastic tensegrity braces for timber frames equipped with buckling-restrained devices,” International Journal of Solids and Structures 281, article 112414. DOI: 10.1016/j.ijsolstr.2023.112414

Froozanfar, M., Moradi, S., Kianoush, R., Speicher, M. S., and Di Sarno, L. (2024). “Review of self-centering rocking systems for earthquake-resistant building structures: State of the art,” Journal of Building Engineering 84, article 108607. DOI: 10.1016/j.jobe.2024.108607

Ganey, R., Berman, J., Akbas, T., Loftus, S., Daniel Dolan, J., Sause, R., Ricles, J., Pei, S., Lindt, J. v. d., and Blomgren, H.-E. (2017). “Experimental investigation of self-centering cross-laminated timber walls,” Journal of Structural Engineering 143(10), article 04017135. DOI: 10.1061/(ASCE)ST.1943-541X.0001877

Gao, Z., Qian, Y., Dersch, M. S., and Edwards, J. R. (2017). “Compressive stress distribution in prestressed concrete and its effect on railroad crosstie design,” Construction and Building Materials 151, 147-157. DOI: 10.1016/j.conbuildmat.2017.05.186

Garas, F. K., and Chalmers, A. G. (1980). “Development of prestressed concrete pressure vessels for HTR,” Nuclear Engineering and Design 61(1), 61-77. DOI: 10.1016/0029-5493(80)90078-3

Gasparini, D. (2006). “The prestressing of structures: A historical review,” in: Proceedings of the Second International Congress on Construction History.

Gasparini, D., Bruckner, J., and da Porto, F. (2006). “Time-dependent behavior of posttensioned wood Howe bridges,” Journal of Structural Engineering 132(3), 418-429. DOI: 10.1061/(ASCE)0733-9445(2006)132:3(418)

Gasparini, D., and Simmons, D. (1997a). “American truss bridge connections in the 19th century. I: 1829-1850,” Journal of Performance of Constructed Facilities 11(3), 119-129. DOI: 10.1061/(ASCE)0887-3828(1997)11:3(119)

Gasparini, D., and Simmons, D. (1997b). “American truss bridge connections in the 19th century. II: 1850-1900,” Journal of Performance of Constructed Facilities 11(3), 130-140. DOI: 10.1061/(ASCE)0887-3828(1997)11:3(130)

Gattesco, N., and Boem, I. (2016). “Stress distribution among sheathing-to-frame nails of timber shear walls related to different base connections: Experimental tests and numerical modelling,” Construction and Building Materials 122, 149-162. DOI: 10.1016/j.conbuildmat.2016.06.079

Gessner, S., Spelter, A., Walter, B., Judt, P., and Hegger, J. (2019). “Prestressed timber components in structural timber construction – Experimental and theoretical investigations of prestressed laminated timber panel ceilings,” Bautechnik 96(11), 800-814. DOI: 10.1002/bate.201900046

Giongo, I., Piazza, M., and Tomasi, R. (2013). “Investigation on the self-tapping screws capability to induce internal stress in timber elements,” Advanced Materials Research 778, 604-611. DOI: 10.4028/www.scientific.net/AMR.778.604

Granello, G., Broccardo, M., Palermo, A., and Pampanin, S. (2020). “Fragility-based methodology for evaluating the time-dependent seismic performance of post-tensioned timber frames,” Earthquake Spectra 36(1), 322-352. DOI: 10.1177/8755293019878196

Granello, G., Leyder, C., Frangi, A., Palermo, A., and Chatzi, E. (2019). “Long-term performance assessment of an operative post-tensioned timber frame structure,” Journal of Structural Engineering 145(5), article 04019034. DOI: 10.1061/(ASCE)ST.1943-541X.0002308

Granello, G., Leyder, C., Palermo, A., Frangi, A., and Pampanin, S. (2018). “Design approach to predict post-tensioning losses in post-tensioned timber frames,” Journal of Structural Engineering 144(8), article 04018115. DOI: 10.1061/(ASCE)ST.1943-541X.0002101

Guo, N., Wang, W., and Zuo, H. (2018). “Environmental study on flexural behavior of prestressed glued bamboo-lumber beams after long-term loading,” Ekoloji 27(106), 1819-1827.

Guo, N., Wang, W., and Zuo, H. (2019). “Flexural property of string beam of pre-stressed glulam based on influence of regulation and control,” Structural Durability & Health Monitoring 13(2), 143. DOI: 10.32604/sdhm.2019.04640

Guo, N., Wu, M., Li, L., Li, G., and Zhao, Y. (2021). “Bending performance of prestressed continuous glulam beams,” Advances in Civil Engineering 2021, article 5512350. DOI: 10.1155/2021/5512350

Guo, N., Zhou, S., Zhao, Y., Mei, L., and Zhang, Y. (2022). “Experimental study on long-term mechanical properties of prestressed glulam continuous beams,” Materials 15(12), article 4182. DOI: 10.3390/ma15124182

Gustafson, S., Baudisch, P., Gutwin, C., and Irani, P. (2008). “Wedge: Clutter-free visualization of off-screen locations,” in: Proceedings of the SIGCHI Conference on Human Factors in Computing Systems. DOI: 10.1145/1357054.1357179

Hadhood, A., Mohamed, H. M., Mwiseneza, C., and Benmokrane, B. (2021). “Performance of innovative precast concrete sleepers prestressed with glass fiber-reinforced polymer reinforcing bars,” Aci Structural Journal 118(1), 277-288. DOI: 10.14359/51728186

Hahn, B., Werner, T.-E., and Haller, P. (2019). “Experimental and numerical investigations on adhesively bonded tubular connections for moulded wooden tubes,” Construction and Building Materials 229, article 116829. DOI: 10.1016/j.conbuildmat.2019.116829

Halicka, A., and Slosarz, S. (2021). “Strengthening of timber beams with pretensioned CFRP strips,” Structures 34, 2912-2921. DOI: 10.1016/j.istruc.2021.09.055

Halicka, A., and Slosarz, S. (2022). “Analysis of behavior and failure modes of timber beams prestressed with CFRP strips,” Composite Structures 301, article 116171. DOI: 10.1016/j.compstruct.2022.116171

Hasani, H., and Ryan, L. K. (2022). “Effect of partition walls on the seismic response of mass-timber buildings with a post-tensioned rocking wall system,” Engineering Structures 262, article 114316. DOI: 10.1016/j.engstruct.2022.114316

He, M., Zheng, X., Lam, F., and Li, Z. (2022). “Potential loss in prestressing tendon forces under long-term service conditions: Cross-laminated timber shear wall applications,” Journal of Structural Engineering 148(3), article 04021284. DOI: 10.1061/(ASCE)ST.1943-541X.0003272

Hossain, A., Danzig, I., and Tannert, T. (2016). “Cross-laminated timber shear connections with double-angled self-tapping screw assemblies,” Journal of Structural Engineering 142(11), article 04016099. DOI: 10.1061/(ASCE)ST.1943-541X.0001572

Howe, W. (1840). “Manner of constructing the truss-frames of bridges and other structures,” U.S. pat. 1711.

https://data.shinkenchiku.online/en/projects/articles/SK_1996_12_240-0.

https://en.wikipedia.org/wiki/Izumo_Dome.

https://en.wikipedia.org/wiki/Royal_Albert_Bridge#cite_note-3.

Huang, Z., Huang, D., Chui, Y.-H., Shen, Y., Daneshvar, H., Sheng, B., and Chen, Z. (2022). “Modeling of cross-laminated timber (CLT) panels loaded with combined out-of-plane bending and compression,” Engineering Structures 250, article 113335. DOI: 10.1016/j.engstruct.2021.113335

Iqbal, A., Fragiacomo, M., Pampanin, S., and Buchanan, A. (2018). “Seismic resilience of plywood-coupled LVL wall panels,” Engineering Structures 167, 750-759. DOI: 10.1016/j.engstruct.2017.09.053

Iqbal, A., Pampanin, S., and Buchanan, A. H. (2016). “Seismic performance of full-scale post-tensioned timber beam-column connections,” Journal of Earthquake Engineering 20(3), 383-405. DOI: 10.1080/13632469.2015.1070386

Iqbal, A., Pampanin, S., Palermo, A., and Buchanan, A. H. (2015). “Performance and design of LVL walls coupled with UFP dissipaters,” Journal of Earthquake Engineering 19(3), 383-409. DOI: 10.1080/13632469.2014.987406

Iqbal, A., and Popovski, M. (2017, April). “Post-tensioned mass timber systems,” in: Structures Congress 2017. DOI: 10.1061/9780784480427.036

Jacobs, M. R. (1938). The Fibre Tension of Woody Stems, with Special Reference to the Genus Eucalyptus, Commonwealth Government Printer, Canbera.

James, J. G. (2017). “The evolution of wooden bridge trusses to 1850,” in: The Development of Timber as a Structural Material, Routledge, pp. 327-372. DOI: 10.4324/9781315240305-17

Jia, S. (2022). “Research on key technologies of large-span glued laminated timber reticulated shell structure design in Taiyuan Botanical Garden,” Building Structure 52(4), 1-5, 62.

Johnsson, H., Blanksvärd, T., and Carolin, A. (2007). “Glulam members strengthened by carbon fibre reinforcement,” Materials and Structures 40, 47-56. DOI: 10.1617/s11527-006-9119-7

Karagöz İşleyen, Ü., Ghoroubi, R., Mercimek, Ö., and Anıl, Ö. (2021). “Behavior of glulam timber beam strengthened with carbon fiber reinforced polymer strip for flexural loading,” Journal of Reinforced Plastics and Composites 40(17-18), 665-685. DOI: 10.1177/0731684421997924

Karagöz İşleyen, Ü., Ghoroubi, R., Mercimek, Ö., Anıl, Ö., and Tuğrul Erdem, R. (2023). “Investigation of impact behavior of glulam beam strengthened with CFRP,” Structures 51, 196-214. DOI: 10.1016/j.istruc.2023.03.038

Khedmatgozar Dolati, S. S., and Mehrabi, A. (2022). “FRP sheet/jacket system as an alternative method for splicing prestressed-precast concrete piles,” Case Studies in Construction Materials 16, article e00912. DOI: 10.1016/j.cscm.2022.e00912

Kim, K.-M., Eom, C.-D., and Lee, S.-J. (2011). “Performance of structural glulam laminated with CuAz-3 preservative treated lumber,” Journal of the Korean Wood Science and Technology 39(6), 521-530. DOI: 10.5658/WOOD.2011.39.6.521

Krishnan, S. (2020). “Cable-stayed columns and their applications in building structures,” Journal of Building Engineering 27, article 100984. DOI: 10.1016/j.jobe.2019.100984

Lam, F., Gehloff, M., and Closen, M. (2010). “Moment-resisting bolted timber connections,” Proceedings of the Institution of Civil Engineers-Structures and Buildings 163(4), 267-274. DOI: 10.1680/stbu.2010.163.4.267

Lee, A. W., Bai, X., and Bangi, A. P. (1998). “Selected properties of laboratory-made laminated-bamboo lumber,” Holzforschung 52, 207-210. DOI: 10.1515/hfsg.1998.52.2.207

Lee, S., Seo, M., Kim, S.-M., Vo, T. P., and Lee, J. (2023). “Effects of design parameters on the static responses of two-way beam string structure,” Mechanics Based Design of Structures and Machines 51(11), 6374-6392. DOI: 10.1080/15397734.2022.2041437

Lehmann, M. (2015). Investigations of the Loadbearing Behaviour of Timber Bending Beams Reinforced Using Prestressed CFRP-Lamellas (Doctoral dissertation, Bauhaus-Universität).

Li, H., Lam, F., and Qiu, H. (2017). “Flexural performance of spliced beam connected and reinforced with self-tapping wood screws,” Engineering Structures 152, 523-534. DOI: 10.1016/j.engstruct.2017.08.032

Li, J. (2019). Study on Mechanical Behavior of New Prestressed Steel-Wood Composite Column. [Dissertation, Southwest University of Science and Technology]. https://kns.cnki.net/kcms2/article/abstract?v=m22VhQxdXycZlqWumIoCgGNaGowD_KuqjuPOB9qmHN6XyzA5vrQkTspq8gTgTGJof4vw-IrR8_PTSAn-N-SzB74fbtRD8g-QAvwdc-5lljm-ZZrBpEMFXobzlfOQxWjRhL4J5qsl9IiO2yOCBzXUsb6hgKmrjzEz&uniplatform=NZKPT&language=CHS

Li, Z., Chen, F., He, M., Long, W., Ou, J., and Li, M. (2023). “Experimental investigation on self-centering steel-timber hybrid beam-column connections,” Journal of Structural Engineering 149(3). DOI: 10.1061/JSENDH.STENG-11570

Li, Z., Zheng, X., He, M., Sun, Y., and He, G. (2020). “Experimental and analytical investigations into the time-dependent performance in post-tensioned timber beam-column joints under sustained loads and varied environment,” Construction and Building Materials 251, article 118943. DOI: 10.1016/j.conbuildmat.2020.118943

Li, Z., Zhou, R., He, M., and Li, M. (2018). “A state-of-the-art review on earthquake resilient timber structures,” Journal of Building Structures 39(9), 10-21.

Li, Z., Zhou, R., He, M., and Sun, X. (2019). “Modern timber construction technology and engineering applications in China,” Proceedings of the Institution of Civil Engineers – Civil Engineering 172(5), 17-27. DOI: 10.1680/jcien.18.00024

Lim, T. H., Ellis, B. R., and Skerlos, S. J. (2023). “Life cycle assessment of railway ties fabricated with ductile cementitious composites and carbonation curing,” Journal of Cleaner Production 413, article 137276. DOI: 10.1016/j.jclepro.2023.137276

Liu, W., and Yang, H. (2019). “Research progress on modern timber structures,” Journal of Building Structures 40(2), 16-43.

Liu, W., Yang, H., Dong, F., and Jiang, D. (2008). “Experimental study on flexural behavior of glulam and laminated veneer lumber beams,” in: Modern Bamboo Structures, CRC Press, pp. 171-182. DOI: 10.1201/9780203888926-23

Liu, X., Smith, G. D., Jiang, Z., Bock, M. C., Boeck, F., Frith, O., Gatóo, A., Liu, K., Mulligan, H., and Semple, K. E. (2016). “Nomenclature for engineered bamboo,” BioResources 11(1), 1141-1161. DOI: 10.15376/biores.11.1.1141-1161

Long, S. (1830). “Wooden-framed brace-bridges,” English. US pat. X, 5862.

Lu, Y., Liu, Y., and Lv, Q. (2024). “Experimental study on the hysteretic performance of a self-centering frame infilled with a bamboo wall,” Engineering Structures 314, article 118383. DOI: 10.1016/j.engstruct.2024.118383

Lu, Y., Lv, Q., and Liu, Y. (2022). “Experimental and numerical study on seismic performance of CLB rocking wall with bending-friction coupled dampers,” Journal of Building Engineering 45, article 103622. DOI: 10.1016/j.jobe.2021.103622

Lv, Q., Ding, Y., and Liu, Y. (2019). “Effect of the nonprestressed/prestressed BFRP bar on flexural performance of the bamboo beam,” Advances in Polymer Technology 2019, article 7143023. DOI: 10.1155/2019/7143023

Lv, Q., Liu, Y., and Ding, Y. (2019). “Analyses on prestress loss and flexural performance of the laminated bamboo beam applied with prestressed BFRP sheet,” Advances in Civil Engineering 2019, article 2319814. DOI: 10.1155/2019/2319814

McClure, F. A. (1956). “Bamboo as a building material,” Tropical Housing & Planning Monthly Bulletin 2(14/15), 79-90.

McConnell, E., McPolin, D., and Taylor, S. (2014). “Post-tensioning of glulam timber with steel tendons,” Construction and Building Materials 73, 426-433. DOI: 10.1016/j.conbuildmat.2014.09.079

Miliziano, A., Granello, G., Palermo, A., and Pampanin, S. (2020). “Overview of connection detailing for post-tensioned dissipative timber frames,” Structural Engineering International 30(2), 209-216. DOI: 10.1080/10168664.2020.1736968

Morano, S. G., and Mannini, C. (2006). “Preflex beams: A method of calculation of creep and shrinkage effects,” Journal of Bridge Engineering 11(1), 48-58. DOI: 10.1061/(ASCE)1084-0702(2006)11:1(48)

Motavalli, M., Czaderski, C., Schumacher, A., and Gsell, D. (2010). “4 – Fibre reinforced polymer composite materials for building and construction,” in: Textiles, Polymers and Composites for Buildings, G. Pohl (ed.), Woodhead Publishing, pp. 69-128. DOI: 10.1533/9780845699994.1.69

Müller, K. (2020). Timber-concrete Composite Slabs with Micro-notches, ETH Zurich.

Müller, K., Grönquist, P., Cao, A. S., and Frangi, A. (2021). “Self-camber of timber beams by swelling hardwood inlays for timber–concrete composite elements,” Construction and Building Materials 308, article 125024. DOI: 10.1016/j.conbuildmat.2021.125024

Münch, E. (1938). “Statik und Dynamik des schraubigen Baues der Zellwand, besonders des Druck- und Zugholzes,” Flora oder Allgemeine Botanische Zeitung 132(4), 357-424. DOI: 10.1016/S0367-1615(17)31909-2

Negrão, J. H. (2016). “Preliminary study on wire prestressing methods for timber pieces reinforcement,” Construction and Building Materials 102, 1093-1100. DOI: 10.1016/j.conbuildmat.2014.11.050

Newcombe, M. P., Pampanin, S., Buchanan, A., and Palermo, A. (2008). “Section analysis and cyclic behavior of post-tensioned jointed ductile connections for multi-story timber buildings,” Journal of Earthquake Engineering 12, 83-110. DOI: 10.1080/13632460801925632

Nguyen, T. T., Dao, T. N., Aaleti, S., van de Lindt, J. W., and Fridley, K. J. (2018). “Seismic assessment of a three-story wood building with an integrated CLT-lightframe system using RTHS,” Engineering Structures 167, 695-704. DOI: 10.1016/j.engstruct.2018.01.025

Nie, X., Zhang, S., Jiang, T., and Yu, T. (2020). “The strong column–weak beam design philosophy in reinforced concrete frame structures: A literature review,” Advances in Structural Engineering 23(16), 3566-3591. DOI: 10.1177/1369433220933463

Nie, Y. J., and Li, T. Y. (2012). “Vibration reducing analysis of beam string structure with seismic isolation bearings,” Advanced Materials Research 383, 4748-4754. DOI: 10.4028/www.scientific.net/AMR.383-390.4748

Norrie, C. M. (1956). Bridging the Years: A Short History of British Civil Engineering, Edward Arnold publ., 212 pp.

Omenzetter, P., Morris, H., Worth, M., Kohli, V., and Uma, S. (2011). “Long-term monitoring and field testing of an innovative multistory timber building,” in: Nondestructive Characterization for Composite Materials, Aerospace Engineering, Civil Infrastructure, and Homeland Security 2011. DOI: 10.1117/12.879869

Palermo, A., Giorgini, S., Pampanin, S., and Buchanan, A. H. (2011). “Potential of longitudinal post-tensioning for short-to-medium span timber bridges,” Structural Engineering International 21(3), 349-355. DOI: 10.2749/101686611X13049248220320

Palermo, A., Pampanin, S., Buchanan, A., and Newcombe, M. (2005). “Seismic design of multi-storey buildings using laminated veneer lumber (LVL),” in: Wairakei, New Zealand: NZ Society of Earthquake Engineering, Annual National Conference, March 2005.

Paliszewska-Mojsiuk, M. (2018). “History of the Forbidden City,” Nowa Polityka Wschodnia, 203. DOI: 10.15804/npw20181913

Park, R. (1986). “Ductile design approach for reinforced concrete frames,” Earthquake Spectra 2(3), 565-619. DOI: 10.1193/1.1585398

Paulay, T. (1986). “The design of ductile reinforced concrete structural walls for earthquake resistance,” Earthquake Spectra 2(4), 783-823. DOI: 10.1193/1.1585411

Peterson, J. (1965). “Wood beams prestressed with bonded tension elements,” Journal of the Structural Division 91(1), 103-119. DOI: 10.1061/JSDEAG.0001199

Petrycki, A., and Salem, O. S. (2020). “Structural integrity of bolted glulam frame connections reinforced with self-tapping screws in a column removal scenario,” Journal of Structural Engineering 146(10), article 04020213. DOI: 10.1061/(ASCE)ST.1943-541X.0002792

Piri, M., and Massumi, A. (2022). “Seismic performance of steel moment and hinged frames with rocking shear walls,” Journal of Building Engineering 50, article 104121. DOI: 10.1016/j.jobe.2022.104121

Priestley, M. N., and Calvi, G. M. (1991). “Towards a capacity-design assessment procedure for reinforced concrete frames,” Earthquake Spectra 7(3), 413-437. DOI: 10.1193/1.1585635

Qiu, H., Liu, D., Wang, Y., Lai, X., and Zhang, H. (2021). “Numerical simulation of the axial compression preformance of prestressed thin-walled steel confined square timber column,” Building Science 37(9), 47-54.

Quenneville, J. H., and Mohammad, M. (2000). “On the failure modes and strength of steel-wood-steel bolted timber connections loaded parallel-to-grain,” Canadian Journal of Civil Engineering 27(4), 761-773. DOI: 10.1139/l00-020

Quenneville, P., and Vandalen, K. (1994a). Relaxation behavior of prestressed wood assemblies. 1. Experimental study,” Canadian Journal of Civil Engineering 21(5), 736-743. DOI: 10.1139/l94-079

Quenneville, P., and Vandalen, K. (1994b). “Relaxation behavior of prestressed wood assemblies. 2. Theoretical study,” Canadian Journal of Civil Engineering 21(5), 744-751. DOI: 10.1139/l94-080

Quiquero, H., Gales, J., Abu, A., and Al Hamd, R. (2020). “Finite element modelling of post-tensioned timber beams at ambient and fire conditions,” Fire Technology 56(2), 737-767. DOI: 10.1007/s10694-019-00901-0

Ranzi, G., and Ostinelli, A. (2017). “Ultimate behaviour and design of post-tensioned composite slabs,” Engineering Structures 150, 711-718. DOI: 10.1016/j.engstruct.2017.07.075

Riccadonna, D., Walsh, K., Schiro, G., Piazza, M., and Giongo, I. (2020). “Testing of long-term behaviour of pre-stressed timber-to-timber composite (TTC) floors,” Construction and Building Materials 236, article 117596. DOI: 10.1016/j.conbuildmat.2019.117596

Robati, M., and Oldfield, P. (2022). “The embodied carbon of mass timber and concrete buildings in Australia: An uncertainty analysis,” Building and Environment 214, article 108944. DOI: 10.1016/j.buildenv.2022.108944

Rocha, J., Pereira, E., Michels, J., and Sena-Cruz, J. (2023). “Hybrid strengthening and flexural behaviour of post-tensioned laminated glass beams,” Construction and Building Materials 408, article 133637. DOI: 10.1016/j.conbuildmat.2023.133637

Ruan, G., Filz, G. H., and Fink, G. (2022). “Shear capacity of timber-to-timber connections using wooden nails,” Wood Material Science & Engineering 17(1), 20-29. DOI: 10.1080/17480272.2021.1964595

Rumlová, J., and Fojtík, R. (2015). “The timber tie beam: The analysis of spatial framework joint,” Procedia Engineering 114, 132-139. DOI: 10.1016/j.proeng.2015.08.051

Saitoh, M. (1998). “Aesthetics and technology of the beam string structures,” in: IASS International Symposium’98 on lightweight structures in Architecture, Engineering and Construction.

Saitoh, M., and Okada, A. (1999). “The role of string in hybrid string structure,” Engineering Structures 21(8), 756-769. DOI: 10.1016/S0141-0296(98)00029-7

Sarti, F., Palermo, A., and Pampanin, S. (2016). “Development and testing of an alternative dissipative posttensioned rocking timber wall with boundary columns,” Journal of Structural Engineering 142(4), article E4015011. DOI: 10.1061/(ASCE)ST.1943-541X.0001390

Sattar, M. A. (1995). “Traditional bamboo housing in Asia: Present status and future prospects.” Bamboo, People and the Environment 3, 1-13.

Schmid, J., Klippel, M., Just, A., and Frangi, A. (2014). “Review and analysis of fire resistance tests of timber members in bending, tension and compression with respect to the Reduced Cross-Section Method.” Fire Safety Journal 68, 81-99. DOI: 10.1016/j.firesaf.2014.05.006

Schiro, G., Giongo, I., Sebastian, W., Riccadonna, D., and Piazza, M. (2018). “Testing of timber-to-timber screw-connections in hybrid configurations,” Construction and Building Materials 171, 170-186. DOI: 10.1016/j.conbuildmat.2018.03.078

Sehlström, A. (2019). Prestress in Nature and Technics, Chalmers Tekniska Hogskola (Sweden).

Sehlström, A. (2021). Prestress and its Application to Shell, Fabric, and Cable Net Structures, Chalmers Tekniska Hogskola (Sweden).

Sejkot, P., Ormarsson, S., Vessby, J., and Källsner, B. (2020). “Numerical out-of-plane stability analysis of long span timber trusses with focus on buckling length calculations,” Engineering Structures 204, article 109670. DOI: 10.1016/j.engstruct.2019.109670

Shu, Z., Li, Z., He, M., Zheng, X., and Wu, T. (2019). “Seismic design and performance evaluation of self-centering timber moment resisting frames,” Soil Dynamics and Earthquake Engineering 119, 346-357. DOI: 10.1016/j.soildyn.2018.08.038

Sinha, A., Way, D., and Mlasko, S. (2014). “Structural performance of glued laminated bamboo beams,” Journal of Structural Engineering 140(1), article 04013021. DOI: 10.1061/(ASCE)ST.1943-541X.0000807

Smith, J. T. (1965). “Timber-framed building in England,” Archaeological Journal 122(1), 133-158. DOI: 10.1080/00665983.1965.11077365

Smith, T., Ponzo, F. C., Di Cesare, A., Pampanin, S., Carradine, D., Buchanan, A. H., and Nigro, D. (2014). “Post-tensioned glulam beam-column joints with advanced damping systems: Testing and numerical analysis,” Journal of Earthquake Engineering 18(1), 147-167. DOI: 10.1080/13632469.2013.835291

Smith, T., Watson, C., Moroder, D., Pampanin, S., and Buchanan, A. (2016). “Lateral performance of a Pres-Lam frame designed for gravity loads,” Engineering Structures 122, 33-41. DOI: 10.1016/j.engstruct.2016.05.005

Song, Y., He, L., Wang, J., Hong, X., and Han, J. (2002). “Theoretical analysis of deflection evaluation of pre-stressed timber structure under concentrated load.” Journal of Gansu University of Technology 28(1), 92-94.

Song, X., Ma, Y., Gu, X., et al. (2017). “Carbon fiber-reinforced polymer reinforcement for rotational behavior of bolted glulam beam-to-column connections,” Journal of Composites for Construction, ASCE, 21(3), article 04016096. DOI: 10.1061/(ASCE)CC.1943-5614.0000753

Stöcklin, I., and Meier, U. (2003). “Strengthening of concrete structures with prestressed and gradually anchored CFRP strips,” in: Fibre-Reinforced Polymer Reinforcement for Concrete Structures (in 2 Volumes), World Scientific, pp. 1321-1330. DOI: 10.1142/9789812704863_0127

Stratford, T., and Cadei, J. (2006). “Elastic analysis of adhesion stresses for the design of a strengthening plate bonded to a beam,” Construction and Building Materials 20(1), 34-45. DOI: 10.1016/j.conbuildmat.2005.06.041

Sun, X., He, M., and Li, Z. (2020). “Experimental and analytical lateral performance of posttensioned CLT shear walls and conventional CLT shear walls,” Journal of Structural Engineering 146(6), article 04020091. DOI: 10.1061/(ASCE)ST.1943-541X.0002638

Sun, X., He, M., Li, Z., and Lam, F. (2020). “Seismic performance of energy-dissipating post-tensioned CLT shear wall structures. I: Shear wall modeling and design procedure,” Soil Dynamics and Earthquake Engineering 131, article 106022. DOI: 10.1016/j.soildyn.2019.106022

Sun, X., Liu, W., Lu, W., Zhu, X., and Yuan, S. (2016). “Experimental research on flexural behavior of glulam beam string structure and engineering application,” Journal of Nanjing University of Technology 38(05), 121-128.

Sutherland, R. (2016). Structural Iron 1750–1850, Routledge. DOI: 10.4324/9781315242224

Thi, N. D., and Ha, P. T. H. (2017). “Using bamboo in traditional housing and modern architecture,” Journal of Science and Technology in Civil Engineering (JSTCE)-HUCE 11(6), 117-123.

Tian, P., Qiu, H., and Wang, H. (2021). “Influence of shrinkage cracks on the mechanical properties of bolted-type glulam joint with slotted-in steel plate: Experimental study,” Journal of Building Engineering 44, article 102632. DOI: 10.1016/j.jobe.2021.102632

Tian, Y., Li, H., Chen, B., Lorenzo, R., and Ashraf, M. (2023). “Experimental and theoretical investigation of prestressed-steel-reinforced laminated bamboo lumber beams,” Structures 47, 434-448. DOI: 10.1016/j.istruc.2022.10.135

Totman, C. D. (1983). “Logging the unloggable: Timber transport in early modern Japan,” Journal of Forest History 27(4), 180-191. DOI: doi:10.2307/4004898

Triantafillou, T. C., and Deskovic, N. (1992). “Prestressed FRP sheets as external reinforcement of wood members,” Journal of Structural Engineering-ASCE 118(5), 1270-1284. DOI: 10.1061/(ASCE)0733-9445(1992)118:5(1270)

Tsubota, H., Ban, S., and Saito, M. (1993). “The Izumo Dome, largest timber structure in Japan,” Structural Engineering International 3(2), 79-81. DOI: 10.2749/101686693780612358

Verna, J. R., Graham Jr, J. F., Shannon, J. M., and Sanders, P. H. (1984). “Timber bridges: Benefits and costs,” Journal of Structural Engineering 110(7), 1563-1571. DOI: 0.1061/(ASCE)0733-9445(1984)110:7(1563)

Wang, G., Zhang, L., Xu, C., Zhang, S., Zhou, Z., Guo, S., Ji, X., and Lei, H. (2024). “Analysis of factors affecting the stability of large-span cable-braced timber gridshells,” Developments in the Built Environment 17, article 100360. DOI: 10.1016/j.dibe.2024.100360

Wang, K., Shi, T., Omar, A. A., Mohibullah, M., Luo, H., Chen, W., and Yang, Y. (2024). “Study on seismic performance of prestressed composite joint with CESA columns,” Journal of Building Engineering 82, article 108330. DOI: 10.1016/j.jobe.2023.108330

Wang, X., Shen, S., Jin, T., Yuan, H., and Zhao, S. (2016). “Preliminary study on bending property of wood-bamboo structural glulam reinforced by prestressed FRP,” Journal of Central South University of Forestry & Technology 36(4), 116-119.

Wang, Y., Liu, D., Wang, N., and Ma, J. (2022). “Experimental research on mechanical properties of prestressed steel-timber circular column under axial compression,” Industrial Construction 52(1), 39-46.

Wanninger, F., and Frangi, A. (2014). “Experimental and analytical analysis of a post-tensioned timber connection under gravity loads,” Engineering Structures 70, 117-129. DOI: 10.1016/j.engstruct.2014.03.042

Wanninger, F., Frangi, A., and Fragiacomo, M. (2015). “Long-term behavior of posttensioned timber connections,” Journal of Structural Engineering 141(6), article 04014155. DOI: 10.1061/(ASCE)ST.1943-541X.0001121

Wdowiak-Postulak, A. (2023). “Numerical, theoretical and experimental models of the static performance of timber beams reinforced with steel, basalt and glass pre-stressed bars,” Composite Structures 305, article 116479. DOI: 10.1016/j.compstruct.2022.116479

Wdowiak-Postulak, A., Gocal, J., Bahleda, F., Prokop, J., and Correia, J. A. (2023). “Load and deformation analysis in experimental and numerical studies of full-size wooden beams reinforced with prestressed FRP and steel bars,” Applied Sciences-Basel, 13(24), article 13178. DOI: 10.3390/app132413178

Wdowiak-Postulak, A., Swit, G., and Dziedzic-Jagocka, I. (2024). “Application of composite bars in wooden, full-scale, innovative engineering products-experimental and numerical study,” Materials 17(3). DOI: 10.3390/ma17030730

Wei, J., Xue, J., Ma, L., Zhou, R., and Ge, Z. (2024). “Experimental investigation of transition composite connections in historic style buildings,” Structures 62, article 106265. DOI: 10.1016/j.istruc.2024.106265

Wei, Y., Yan, S., Zhao, K., Dong, F., and Li, G. (2020). “Experimental and theoretical investigation of steel-reinforced bamboo scrimber beams,” Engineering Structures 223, article 111179. DOI: 10.1016/j.engstruct.2020.111179

Wilson, A. W., Motter, C. J., Phillips, A. R., and Dolan, J. D. (2020). “Seismic response of post-tensioned cross-laminated timber rocking wall buildings,” Journal of Structural Engineering 146(7), 04020123. DOI: 10.1061/(ASCE)ST.1943-541X.0002673

Wipf, T. J., Ritter, M. A., and Wood, D. L. (2000). “Evaluation and field load testing of timber railroad bridge,” Transportation Research Record 1696(1), 323-333. DOI: 10.3141/1696-34

Wongpakdee, N., and Leelataviwat, S. (2017). “Influence of column strength and stiffness on the inelastic behavior of strong-column-weak-beam frames,” Journal of Structural Engineering 143(9), article 04017124. DOI: 10.1061/(ASCE)ST.1943-541X.0001864

Wu, W., Wu, Z., Ma, X., Chen, S., and Wei, H. (2014). “Experimental analysis of bending resistance of bamboo composite I-shaped beam,” Journal of Bridge Engineering 19(4), article 04013014. DOI: 10.1061/(ASCE)BE.1943-5592.0000557

Xu, Q., Chen, L., Harries, K. A., Zhang, F., Liu, Q., and Feng, J. (2015). “Combustion and charring properties of five common constructional wood species from cone calorimeter tests,” Construction and Building Materials 96, 416-427. DOI: 10.1016/j.conbuildmat.2015.08.062

Xu, M., Cui, Z., Chen, Z., and Xiang, J. (2018). “The charring rate and charring depth of bamboo scrimber exposed to a standard fire,” Fire and Materials 42(7), 750-759. DOI: 10.1002/fam.2629-

Xu, C., Chen, D., Miramini, S., Liu, X., Xu, W., and Zhang, L. (2023). “Experimental fire performance assessment of a new type of prestressed composite circular precast concrete columns,” Engineering Structures 278, article 115509. DOI: 10.1016/j.engstruct.2022.115509

Yang, H., Liu, W., Lu, W., Zhu, S., and Geng, Q. (2016). “Flexural behavior of FRP and steel reinforced glulam beams: Experimental and theoretical evaluation,” Construction and Building Materials 106, 550-563. DOI: 10.1016/j.conbuildmat.2015.12.135

Yang, Q., Thouless, M., and Ward, S. (1999). “Numerical simulations of adhesively-bonded beams failing with extensive plastic deformation,” Journal of the Mechanics and Physics of Solids 47(6), 1337-1353. DOI: 10.1016/S0022-5096(98)00101-X

Yang, Y., Chen, Z., Wang, X., and Xue, J. (2018). “Experimental study on the axial compression performance of split wooden column reinforced with prestressed steel strips,” Journal of Xi’an University of Architecture & Technology 50(02), 184-189.

Yeoh, D., Fragiacomo, M., De Franceschi, M., and Heng Boon, K. (2011). “State of the art on timber-concrete composite structures: Literature review,” Journal of Structural Engineering 137(10), 1085-1095. DOI: 10.1061/(ASCE)ST.1943-541X.0000353

Yi, N.-H., Choi, S.-J., Lee, S.-W., and Kim, J.-H. J. (2015). “Failure behavior of unbonded bi-directional prestressed concrete panels under RABT fire loading,” Fire Safety Journal 71, 123-133. DOI: 10.1016/j.firesaf.2014.11.010

Yifeng, Z., and Jian, F. (2011). “Statical analysis of progressive collapse in string truss structure,” in: 2011 International Conference on Electric Technology and Civil Engineering (ICETCE).

Zhang, H., Shen, M., Deng, Y., Andras, P., Sukontasukkul, P., Yuen, T. Y. P., Tang, Y., Wong, S. H. F., Limkatanyu, S., Singleton, I., and Hansapinyo, C. (2023). “A new concept of bio-based prestress technology with experimental proof-of-concept on bamboo-timber composite beams,” Construction and Building Materials 402, article 132991. DOI: 10.1016/j.conbuildmat.2023.132991

Zhang, J., Xu, Q., Zhang, M., Cai, J., and Ma, S. (2014). “Experimental research on mechanical performance of arched glulam beam string structure,” Journal of Building Structures 35(05), 104-113.

Zhang, J., Wang, Y., Li, L., and Xu, Q. (2019). “Thermo-mechanical behaviour of dovetail timber joints under fire exposure,” Fire Safety Journal 107, 75-88. DOI: 10.1016/j.firesaf.2017.11.008

Zhang, X., Mao, M., Shan, Q., and Li, Y. (2022). “Experimental study and theoretical analysis on the flexural performance of steel-bamboo composite beams strengthened with externally prestressed steel strands,” Thin-Walled Structures 178, article 109519. DOI: 10.1016/j.tws.2022.109519

Zhang, Y., Su, Z., Ni, W., Zhang, X., and Wang, L. (2024). “Experimental study and theoretical analysis of fire resistance properties of prestressed glued laminated timber beams,” Construction and Building Materials 424, artcile 135967. DOI: 10.1016/j.conbuildmat.2024.135967

Zhao, J., Liu, H., Chen, Z., Zhao, S., Yang, S., and He, F. (2023). “Investigation on the mechanical behavior of glulam beam string,” Structures 52, 582-597. DOI: 10.1016/j.istruc.2023.04.028

Zhao, J., Liu, H., Chen, Z., Zhao, S., Yang, S., and He, F. (2024). “Investigation on the mechanical behavior of two-way glulam beam string,” Journal of Building Engineering 87, article 108931. DOI: 10.1016/j.jobe.2024.108931

Zheng, X., Li, Z., He, M., and Lam, F. (2021). “Experimental investigation on the rheological behavior of timber in longitudinal and transverse compression,” Construction and Building Materials 304, 124633. DOI: 10.1016/j.conbuildmat.2021.124633

Zheng, Y., Liu, W., Shen, S., and Zhao, L. (2019). “Prestress loss of prestressed glulam beam reinforced with FRP,” World Earthquake Engineering 35(03), 99-107.

Zhu, Y., Guan, M., and Fan, Y. (2007). “Prestressing effects of twisted bamboo bundle on the wood-bamboo laminated veneer lumber,” Journal of Nanjing Forestry University. Natural Sciences Edition 31(6), 16-20.

Zuo, H., Sun, X., Zuo, Y., and Guo, N. (2016). “Bending performance test on the prestressed reinforced glue-lumber beam,” Journal of North-East Forestry University, 44(2), 42-46.

Article submitted: June 25, 2024; Peer review completed: July 13, 2024; Revised version received: July 24, 2024; Accepted: October 11, 2024; Published: October 27, 2024.

DOI: 10.15376/biores.19.4.Lv